Performance of enlarged blood pump models with five different impellers

被引:0
|
作者
Chua, LP [1 ]
Yu, SCM [1 ]
Leo, HL [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Prod Engn, Singapore 639798, Singapore
关键词
blood pump model; impeller blade design;
D O I
10.1615/CritRevBiomedEng.v28.i12.220
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
in earlier studies, a 5:1 enlarged pump model of the Kyoto-NTN Magnetically Suspended Centrifugal Blood Pump had been constructed and the flow characteristics investigated. Although the results obtained were satisfactory, the medium used was air. A 5:1 enlarged pump model using water as the medium thus was designed and constructed. Five different impeller blade profile designs were used in the present study. By varying (1) the blade profile design: forward, radial, and backward, (2) the number of blades used, and (3) the rotating speed, the flow characteristics of the pump were investigated. It was found that the impeller with the higher number of blades, used in the forward and straight blade profiles, have the best performance.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 50 条
  • [1] Performance of enlarged blood pump models with five different impellers
    Chua, L.P.
    Yu, S.C.M.
    Leo, H.L.
    Critical Reviews in Biomedical Engineering, 1998, 26 (05):
  • [2] Comparison of flow characteristics of enlarged blood pump models with different impeller design
    Chua, LP
    Yu, SCM
    Leo, HL
    Chan, WK
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1999, 26 (03) : 369 - 378
  • [3] Numerical simulation study of the impellers of the centrifugal pump based on different turbulence models
    Guo, Ao Hui
    Zeng, Yong Zhong
    Liu, Xiao Bing
    APPLIED MATERIALS AND TECHNOLOGIES FOR MODERN MANUFACTURING, PTS 1-4, 2013, 423-426 : 2049 - 2053
  • [4] Measurements of enlarged blood pump models using laser Doppler anemometer
    Chua, L.P.
    Yu, S.C.M.
    Leo, H.L.
    Critical Reviews in Biomedical Engineering, 1998, 26 (05): : 323 - 324
  • [5] Measurements of enlarged blood pump models using laser Doppler anemometer
    Chua, LP
    Yu, SCM
    Leo, HL
    CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 2000, 28 (1-2) : 135 - 140
  • [6] Preliminary measurements of an enlarged blood pump model
    Chua, LP
    Akamatsu, T
    Chan, WK
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1998, 25 (08) : 1055 - 1064
  • [7] Effect of Different Blade Thickness of Impellers on Energy Performance of Mixed-Flow Reactor Coolant Pump
    Wang Q.
    Lai X.
    Ye D.
    Lai, Xide (laixd@mail.xhu.edu.cn), 1600, Atomic Energy Press (41): : 28 - 32
  • [8] Effect of fitting splitter blades on the performance of centrifugal pump impellers
    Ayyad, Ahmed
    AEJ - Alexandria Engineering Journal, 1994, 33 (03):
  • [9] The hemodynamics and blood trauma in axial blood pump under different operating models
    Zhang, Yunpeng
    Wu, Xiangyu
    Wang, Yiming
    Liu, Hongtao
    Liu, Guang-Mao
    ARTIFICIAL ORGANS, 2022, 46 (11) : 2159 - 2170
  • [10] DESIGN OF TOTALLY HYDRODYNAMICALLY SUSPENDED IMPELLERS FOR MINIATURIZED ROTARY BLOOD PUMP
    Amaral, F. K.
    Timms, D.
    Bohning, F.
    Graefe, R.
    Schmitz-Rode, T.
    Steinseifer, U.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2010, 33 (07): : 425 - 425