Role of screw proximity in the fixation of transverse patellar fractures with screws and a wire

被引:18
|
作者
Chang, Chih-Wei [1 ,2 ,3 ]
Chen, Yen-Nien [1 ,4 ]
Li, Chun-Ting [5 ]
Chung, Yu-Hsuan [4 ]
Chang, Chih-Han [1 ]
Peng, Yao-Te [1 ,6 ]
机构
[1] Natl Cheng Kung Univ, Dept BioMed Engn, Tainan, Taiwan
[2] Natl Cheng Kung Univ, Coll Med, Dept Orthoped, Tainan, Taiwan
[3] Natl Cheng Kung Univ, Natl Cheng Kung Univ Hosp, Coll Med, Dept Orthoped, Tainan, Taiwan
[4] Show Chwan Mem Hosp, Dept Orthoped, Changhua, Taiwan
[5] Natl Univ Tainan, Grad Inst Mechatron Syst Engn, Tainan, Taiwan
[6] Met Ind Res & Dev Ctr, Kaohsiung, Taiwan
来源
JOURNAL OF ORTHOPAEDIC SURGERY | 2018年 / 26卷 / 03期
关键词
cannulated screw; finite element method; screw proximity; transverse patellar fracture; wire; STAINLESS-STEEL WIRE; TENSION-BAND; CANNULATED SCREWS; INTERNAL-FIXATION; OPEN REDUCTION; COMPLICATIONS; PLATE; NAIL;
D O I
10.1177/2309499018789705
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Clinical and biomechanical studies have reported that using supportive screws and a wire instead of the common Kirschner wires for modified tension band wiring improves the stability of fractured patellae. However, the effect of screw proximity on the fixation of a fractured patella remains unclear. Therefore a numerical study was conducted to examine the effects of screw proximity on biomechanical responses in a simulated patellar fracture fixed using two parallel cannulated screws and anterior tension band wiring. Methods: A patellar model with a transverse fracture and loads simulating patellar tendon forces applied on the patella were used in the present simulation. The surgical fixation consisted of two 4.0-mm parallel partially threaded cannulated screws with a figure-of-eight tension band made using a 1.25-mm stainless steel wire. Biomechanical responses at two screw proximities, 5 and 10 mm from the leading edge of the patella, were investigated. Results: Superficial screw placement (5 mm) yielded higher stability, lower wire loads, and lower bone contact pressures than the deep placement (10 mm). The deep placement of screws exerted a higher load on the wire but a lower force on the screw than superficial placement did. Conclusion: This is the first numerical study to examine the effects of screw location on the fixation of a fractured patella using cannulated screws and tension band wiring. Considering the favorable biomechanical responses, superficial placement (5 mm below the leading edge of the patella) is recommended for screw insertion when treating a transverse fractured patella.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Open reduction and internal fixation of comminuted patellar fractures with headless compression screws and wiring technique
    Suh, Kuen Tak
    Suh, Jung Dong
    Cho, Hyung Joon
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2018, 23 (01) : 97 - 104
  • [22] BIODEGRADABLE WIRE FIXATION IN OLECRANON AND PATELLA FRACTURES COMBINED WITH BIODEGRADABLE SCREWS OR PLUGS AND COMPARED WITH METALLIC FIXATION
    JUUTILAINEN, T
    PATIALA, H
    ROKKANEN, P
    TORMALA, P
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1995, 114 (06) : 319 - 323
  • [23] Open Reduction and Internal Fixation of Patellar Fractures with Tension Band Wiring through Cannulated Screws
    Malik, Mudasir
    Halwai, Manzoor Ahmad
    JOURNAL OF KNEE SURGERY, 2014, 27 (05) : 377 - 381
  • [24] A double button adjustable loop device is biomechanically equivalent to tension band wire in the fixation of transverse patellar fractures-A cadaveric study
    Han, Fucai
    Pearce, Christopher Jon
    Ng, David Q. K.
    Ramruttun, Amit K.
    Chong, Desmond Y. R.
    Murphy, Diarmuid
    Lim, Chin Tat
    Lee, Bernard C. S.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (02): : 270 - 276
  • [25] Comparison of Functional and Radiological Outcomes of Transverse Patellar Fractures Fixed with Tension Band Fixation Using Cannulated Screws and Kirschner Wires: A Prospective Randomized Study
    Nikhil Drolia
    Siddhartha Sinha
    Shiva Raj Paneru
    Arvind Kumar
    Javed Jameel
    Sandeep Kumar
    Bikram Shrestha
    Guru P. Khanal
    Indian Journal of Orthopaedics, 2022, 56 : 369 - 376
  • [26] Comparison of Functional and Radiological Outcomes of Transverse Patellar Fractures Fixed with Tension Band Fixation Using Cannulated Screws and Kirschner Wires: A Prospective Randomized Study
    Drolia, Nikhil
    Sinha, Siddhartha
    Paneru, Shiva Raj
    Kumar, Arvind
    Jameel, Javed
    Kumar, Sandeep
    Shrestha, Bikram
    Khanal, Guru P.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2022, 56 (03) : 369 - 376
  • [27] Intramedullary hip screw fixation of reverse oblique and transverse trochanteric femur fractures
    Inglis, Mark R. B.
    Jaarsma, Ruurd L.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2008, 18 (05): : 323 - 326
  • [28] Intramedullary hip screw fixation of reverse oblique and transverse trochanteric femur fractures
    Mark R. B. Inglis
    Ruurd L. Jaarsma
    European Journal of Orthopaedic Surgery & Traumatology, 2008, 18 : 323 - 326
  • [29] A novel technique for treating simple transverse patellar fractures using cannulated screws: a cadaveric and clinical study
    Feng Han
    Zhenjia Zhong
    Ming Zhou
    Qi Chen
    Yinan Liu
    Yongjun Rui
    Fengfeng Li
    Journal of Orthopaedic Surgery and Research, 18
  • [30] A novel technique for treating simple transverse patellar fractures using cannulated screws: a cadaveric and clinical study
    Han, Feng
    Zhong, Zhenjia
    Zhou, Ming
    Chen, Qi
    Liu, Yinan
    Rui, Yongjun
    Li, Fengfeng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)