Role of screw proximity in the fixation of transverse patellar fractures with screws and a wire

被引:18
|
作者
Chang, Chih-Wei [1 ,2 ,3 ]
Chen, Yen-Nien [1 ,4 ]
Li, Chun-Ting [5 ]
Chung, Yu-Hsuan [4 ]
Chang, Chih-Han [1 ]
Peng, Yao-Te [1 ,6 ]
机构
[1] Natl Cheng Kung Univ, Dept BioMed Engn, Tainan, Taiwan
[2] Natl Cheng Kung Univ, Coll Med, Dept Orthoped, Tainan, Taiwan
[3] Natl Cheng Kung Univ, Natl Cheng Kung Univ Hosp, Coll Med, Dept Orthoped, Tainan, Taiwan
[4] Show Chwan Mem Hosp, Dept Orthoped, Changhua, Taiwan
[5] Natl Univ Tainan, Grad Inst Mechatron Syst Engn, Tainan, Taiwan
[6] Met Ind Res & Dev Ctr, Kaohsiung, Taiwan
来源
JOURNAL OF ORTHOPAEDIC SURGERY | 2018年 / 26卷 / 03期
关键词
cannulated screw; finite element method; screw proximity; transverse patellar fracture; wire; STAINLESS-STEEL WIRE; TENSION-BAND; CANNULATED SCREWS; INTERNAL-FIXATION; OPEN REDUCTION; COMPLICATIONS; PLATE; NAIL;
D O I
10.1177/2309499018789705
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Clinical and biomechanical studies have reported that using supportive screws and a wire instead of the common Kirschner wires for modified tension band wiring improves the stability of fractured patellae. However, the effect of screw proximity on the fixation of a fractured patella remains unclear. Therefore a numerical study was conducted to examine the effects of screw proximity on biomechanical responses in a simulated patellar fracture fixed using two parallel cannulated screws and anterior tension band wiring. Methods: A patellar model with a transverse fracture and loads simulating patellar tendon forces applied on the patella were used in the present simulation. The surgical fixation consisted of two 4.0-mm parallel partially threaded cannulated screws with a figure-of-eight tension band made using a 1.25-mm stainless steel wire. Biomechanical responses at two screw proximities, 5 and 10 mm from the leading edge of the patella, were investigated. Results: Superficial screw placement (5 mm) yielded higher stability, lower wire loads, and lower bone contact pressures than the deep placement (10 mm). The deep placement of screws exerted a higher load on the wire but a lower force on the screw than superficial placement did. Conclusion: This is the first numerical study to examine the effects of screw location on the fixation of a fractured patella using cannulated screws and tension band wiring. Considering the favorable biomechanical responses, superficial placement (5 mm below the leading edge of the patella) is recommended for screw insertion when treating a transverse fractured patella.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Role of an additional third screw in the fixation of transverse patellar fracture with two parallel cannulated screw and anterior wire
    Chang, Chih-Wei
    Chen, Chih-Hsien
    Li, Chun-Ting
    Chen, Yen-Nien
    Yang, Tai-Hua
    Chang, Chia-Jung
    Chang, Chih-Han
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [2] Role of an additional third screw in the fixation of transverse patellar fracture with two parallel cannulated screw and anterior wire
    Chih-Wei Chang
    Chih-Hsien Chen
    Chun-Ting Li
    Yen-Nien Chen
    Tai-Hua Yang
    Chia-Jung Chang
    Chih-Han Chang
    BMC Musculoskeletal Disorders, 21
  • [3] Roles of the screw types, proximity and anterior band wiring in the surgical fixation of transverse patellar fractures: a finite element investigation
    Chen, Chih-Hsien
    Chen, Yen-Nien
    Li, Chun-Ting
    Chang, Chih-Wei
    Chang, Chih-Han
    Peng, Yao-Te
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (1)
  • [4] Roles of the screw types, proximity and anterior band wiring in the surgical fixation of transverse patellar fractures: a finite element investigation
    Chih-Hsien Chen
    Yen-Nien Chen
    Chun-Ting Li
    Chih-Wei Chang
    Chih-Han Chang
    Yao-Te Peng
    BMC Musculoskeletal Disorders, 20
  • [5] FiberWire® is superior in strength to stainless steel wire for tension band fixation of transverse patellar fractures
    Wright, P. B.
    Kosmopoulos, V.
    Cote, R. E.
    Tayag, T. J.
    Nana, A. D.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (11): : 1200 - 1203
  • [6] Triangular configuration with headless compression screws in the fixation of transverse patellar fracture
    Chen, Yen-Nien
    Chang, Chih-Wei
    Chang, Hung-Chih
    Yang, Tai-Hua
    Chang, Chia-Jung
    Li, Chun-Ting
    Chen, Chih-Hsien
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (02): : 698 - 705
  • [7] Arthroscopic Screw Fixation Technique for Transverse Glenoid Fractures
    Wafaisade, Arasch
    Kappel, Paola
    Pfeiffer, Thomas R.
    Lambert, Christophe
    Banerjee, Marc
    ARTHROSCOPY TECHNIQUES, 2021, 10 (11): : E2495 - E2499
  • [8] Supplementary transverse wire fixation through cuneiforms and cuboid in combination with a screw for the comminuted tarsal navicular fractures
    Kazumasa Kimura
    Hideo Adachi
    Masaaki Ogawa
    Hideo Sakamoto
    Archives of Orthopaedic and Trauma Surgery, 2002, 122 : 410 - 413
  • [9] Supplementary transverse wire fixation through cuneiforms and cuboid in combination with a screw for the comminuted tarsal navicular fractures
    Kimura, K
    Adachi, H
    Ogawa, M
    Sakamoto, H
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (07) : 410 - 413
  • [10] Arthroscopic-assisted percutaneous screw fixation of select patellar fractures
    Tandogan, RN
    Demirors, H
    Tuncay, CI
    Cesur, N
    Hersekli, M
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (02): : 156 - 162