A novel hybrid closed-loop control approach for dexterous prosthetic hand based on myoelectric control and electrical stimulation

被引:9
|
作者
Jiang, Li [1 ]
Huang, Qi [1 ]
Yang, Dapeng [1 ,2 ]
Fan, Shaowei [1 ]
Liu, Hong [1 ]
机构
[1] Harbin Inst Technol, State Key Lab Robot & Syst, Harbin, Heilongjiang, Peoples R China
[2] Harbin Inst Technol, China & Artificial Intelligence Lab, Harbin, Heilongjiang, Peoples R China
基金
高等学校博士学科点专项科研基金; 中国国家自然科学基金;
关键词
Finite state machine; Hybrid closed-loop control; Myoelectric control; Noise cancellation; Spatial-frequency coding; Transcutaneous electrical nerve stimulation; OF-THE-ART; SENSORY-FEEDBACK;
D O I
10.1108/IR-12-2017-0209
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Purpose - The purpose of this study is to present a novel hybrid closed-loop control method together with its performance validation for the dexterous prosthetic hand. Design/methodology/approach - The hybrid closed-loop control is composed of a high-level closed-loop control with the user in the closed loop and a low-level closed-loop control for the direct robot motion control. The authors construct the high-level control loop by using electromyography (EMG)-based human motion intent decoding and electrical stimulation (ES)-based sensory feedback. The human motion intent is decoded by a finite state machine, which can achieve both the patterned motion control and the proportional force control. The sensory feedback is in the form of transcutaneous electrical nerve stimulation (TENS) with spatial-frequency modulation. To suppress the TENS interfering noise, the authors propose biphasic TENS to concentrate the stimulation current and the variable step-size least mean square adaptive filter to cancel the noise. Eight subjects participated in the validation experiments, induding pattern selection and egg grasping tasks, to investigate the feasibility of the hybrid closed-loop control in clinical use. Findings - The proposed noise cancellation method largely reduces the ES noise artifacts in the EMG electrodes by 18.5 dB on average. Compared with the open-loop control, the proposed hybrid closed-loop control method significantly improves both the pattern selection efficiency and the egg grasping success rate, both in blind operating scenarios (improved by 1.86 s, p < 0.001, and 63.7 per cent, p < 0.001) or in common operating scenarios (improved by 0.49 s, p = 0.008, and 41.3 per cent, p < 0.001). Practical implications - The proposed hybrid closed-loop control method can be implemented on a prosthetic hand to improve the operation efficiency and accuracy for fragile objects such as eggs. Originality/value - The primary contribution is the proposal of the hybrid closed-loop control, the spatial-frequency modulation method for the sensory feedback and the noise cancellation method for the integrating of the myoelectric control and the ES-based sensory feedback.
引用
收藏
页码:526 / 538
页数:13
相关论文
共 50 条
  • [41] Evolving Fuzzy Models for Prosthetic Hand Myoelectric-Based Control
    Precup, Radu-Emil
    Teban, Teodor-Adrian
    Albu, Adriana
    Borlea, Alexandra-Bianca
    Zamfirache, Iuliu Alexandru
    Petriu, Emil M.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (07) : 4625 - 4636
  • [42] Evolving Fuzzy Models for Myoelectric-based Control of a Prosthetic Hand
    Precup, Radu-Emil
    Teban, Teodor-Adrian
    de Oliveira, Thiago Eustaquio Alves
    Petriu, Emil M.
    2016 IEEE INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS (FUZZ-IEEE), 2016, : 72 - 77
  • [43] PCA and deep learning based myoelectric grasping control of a prosthetic hand
    Chuanjiang Li
    Jian Ren
    Huaiqi Huang
    Bin Wang
    Yanfei Zhu
    Huosheng Hu
    BioMedical Engineering OnLine, 17
  • [44] PCA and deep learning based myoelectric grasping control of a prosthetic hand
    Li, Chuanjiang
    Ren, Jian
    Huang, Huaiqi
    Wang, Bin
    Zhu, Yanfei
    Hu, Huosheng
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [45] Implantable IoT System for Closed-Loop Epilepsy Control based on Electrical Neuromodulation
    Ranjandish, Reza
    Schmid, Alexandre
    PROCEEDINGS OF THE 2018 26TH IFIP/IEEE INTERNATIONAL CONFERENCE ON VERY LARGE SCALE INTEGRATION (VLSI-SOC), 2018, : 155 - 158
  • [46] A Robust and Adaptive Control Algorithm for Closed-Loop Brain Stimulation
    Fang, Hao
    Yang, Yuxiao
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 6049 - 6052
  • [47] Closed-Loop Control of Deep Brain Stimulation: A Simulation Study
    Santaniello, Sabato
    Fiengo, Giovanni
    Glielmo, Luigi
    Grill, Warren M.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2011, 19 (01) : 15 - 24
  • [48] The impact of the stimulation frequency on closed-loop control with electrotactile feedback
    Paredes, Liliana P.
    Dosen, Strahinja
    Rattay, Frank
    Graimann, Bernhard
    Farina, Dario
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2015, 12
  • [49] Closed-Loop Stimulation in the Control of Focal Epilepsy of Insular Origin
    Smith, Joseph R.
    Fountas, Kostas N.
    Murro, Anthony M.
    Park, Yong D.
    Jenkins, Patrick D.
    Morrell, Martha
    Esteller, Rosanna
    Greene, David
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2010, 88 (05) : 281 - 287
  • [50] ACLAC: An approach for adaptive closed-loop anesthesia control
    Marrero, Ayoze
    Mendez, Juan A.
    Maslov, Alexandr V.
    Pechenizkiy, Mykola
    2013 IEEE 26TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2013, : 285 - 290