Bi-directional three-phase rectifier with high-frequency isolation and power factor correction

被引:0
|
作者
García-Gil, R [1 ]
Espí, JM [1 ]
Sanchis-Kilders, E [1 ]
Ejea, JB [1 ]
机构
[1] Univ Valencia, Dipartimento Ingn Elect LE2, E-46003 Valencia, Spain
关键词
D O I
10.1109/PESC.2004.1355289
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper analyzes an isolated bi-directional three-phase rectifier with power factor correction, based on the matrix converter topology. The proposed converter consists of a bi-directional three-phase to one phase cycloconverter or reduced matrix converter and a bi-directional. active rectifier, both implemented by four-quadrant switches (4QSWs). Safe commutation of all the 4QSWs is implemented and incorporated in the soft-switching process. Adding a saturable inductor in series with the leakage inductance reduces switching losses. Experimental results of a 1.2kW, +/-15A and 20kHz switching-frequency prototype with an all-digital control are presented.
引用
收藏
页码:2869 / 2874
页数:6
相关论文
共 50 条
  • [21] Three-phase high power factor rectifier with unidirectional power flow
    Lin, BR
    Yang, TY
    Lee, YC
    PEDS 2003 : FIFTH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1 AND 2, PROCEEDINGS, 2003, : 1375 - 1379
  • [22] Isolated three-phase rectifier unit with high power factor
    Martins, DC
    de Andrade, ES
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-FUNDAMENTAL THEORY AND APPLICATIONS, 2000, 47 (01): : 89 - 96
  • [23] Isolated three-phase rectifier unit with high power factor
    deAndrade, ES
    Martins, DC
    Barbi, I
    INTELEC - EIGHTEENTH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, 1996, : 536 - 542
  • [24] A Single-Stage Three-Phase High Power Factor Rectifier with High-Frequency Isolation and Regulated DC-Bus Based on the DCM SEPIC Converter
    Tibola, Gabriel
    Barbi, Ivo
    2011 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2011, : 2773 - 2776
  • [25] A 12 kW three-phase low THD rectifier with high-frequency isolation and regulated DC output
    de Seixas, FJM
    Barbi, I
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (02) : 371 - 377
  • [26] A Reduced Switch Count Single-Stage Three-Phase Bidirectional Rectifier With High-Frequency Isolation
    Baranwal, Rohit
    Iyer, Kartik V.
    Basu, Kaushik
    Castelino, Gysler F.
    Mohan, Ned
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (11) : 9520 - 9541
  • [27] THREE-PHASE 15KVA UPS SYSTEM WITH POWER FACTOR CORRECTION AND HIGH FREQUENCY TRANSFORMER ISOLATION
    Bascope, Rene P. T.
    Branco, Carlos G. C.
    Cruz, Cicero M. T.
    Filho, Gilberto F. S.
    Bezerra, Luiz D. S.
    2009 BRAZILIAN POWER ELECTRONICS CONFERENCE, VOLS 1 AND 2, 2009, : 937 - 944
  • [28] Three-phase high-power-factor rectifier with three ac power switches
    Lin, BR
    Yang, TY
    Lee, YC
    PROCEEDINGS OF THE 2003 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL III: GENERAL & NONLINEAR CIRCUITS AND SYSTEMS, 2003, : 256 - 259
  • [29] Three Phase Front End Active Boost Rectifier with unity power factor, DC voltage Regulation and Bi-directional power flow
    Jadhav, Pravin T.
    Thombare, R. D.
    More, D. S.
    2014 IEEE INTERNATIONAL CONFERENCE ON CIRCUIT, POWER AND COMPUTING TECHNOLOGIES (ICCPCT-2014), 2014, : 775 - 780
  • [30] Research and Simulation of Active Power Factor Correction Based on the Three-phase Rectifier
    Su, Wang
    Ming, He
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,