The influence of the bowel and bladder preparation protocol for radiotherapy of prostate cancer using kilo-voltage cone beam CT: Our experience

被引:9
|
作者
Heng, S. P. [1 ]
Low, S. H. [2 ]
Sivamany, K. [3 ]
机构
[1] Pantai Hosp Kuala Lumpur, Radiotherapy Unit, Kuala Lumpur 59100, Malaysia
[2] Pantai Hosp Kuala Lumpur, Inst Canc, Kuala Lumpur 59100, Malaysia
[3] Univ Sains Malaysia, George Town, Malaysia
关键词
Bladder; cone beam computed tomography; prostate; rectum; CONFORMAL RADIOTHERAPY; DOSE CALCULATION; RECTAL TOXICITY; VOLUME;
D O I
10.4103/0019-509X.178386
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The purpose of this study is to determine the influence of bladder and bowel preparation protocols on the dose-volume histograms (DVHs) of these organs using the cone beam computed tomography (CBCT)-based intensity modulated radiotherapy (IMRT) treatment planning for prostate cancer patients. The pelvic DVHs of 12 prostate cancer patients were studied using CBCT images obtained immediately before each treatment. Six patients had bladder and bowel preparation protocol whilst the other six patients were the control group. Contoured bladder and rectal volumes on CBCT images were compared with planning computed tomography. All patients were treated with IMRT with 7800 cGy in 39 fractions over 8 weeks. Compared with the patient with bladder preparation protocol, patients without bladder preparation instruction had higher bladder volume and dose variation. The maximum variation in bladder volume was as high as 98% in the control group. Without bowel preparation protocol, the rectal volumes were more variability. Owing to changes in rectal filling on the day of treatment, the maximum variation in rectal volume was as high as + 96%. With bowel preparation protocol, the maximum rectum volume variations were less than 25%. The changes in prostate target dose compared with planning dose were minimal as would be expected from positioning with daily image guidance and gold seed implanted.
引用
收藏
页码:639 / +
页数:6
相关论文
共 50 条
  • [1] Kilo-voltage cone-beam CT for image-guided radiation therapy
    Sonke, JJ
    Remeijer, P
    Betgen, A
    Lebesque, J
    van Herk, M
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S70 - S70
  • [2] Image-guided radiotherapy feasibility study using kilo-voltage cone-beam CT images for patient alignment verification
    Shiu, A
    Wang, C
    Lii, M
    Chang, E
    MEDICAL PHYSICS, 2005, 32 (06) : 1933 - 1934
  • [3] A virtual source model for Kilo-voltage cone beam CT: Source characteristics and model validation
    Spezi, E.
    Volken, W.
    Frei, D.
    Fix, M. K.
    MEDICAL PHYSICS, 2011, 38 (09) : 5254 - 5263
  • [4] Technical Note: Procedure for the calibration and validation of kilo-voltage cone-beam CT models
    Vilches-Freixas, Gloria
    Letang, Jean Michel
    Brousmiche, Sebastien
    Romero, Edward
    Oliva, Marc Vila
    Kellner, Daniel
    Deutschmann, Heinz
    Keuschnigg, Peter
    Steininger, Philipp
    Rit, Simon
    MEDICAL PHYSICS, 2016, 43 (09) : 5199 - 5204
  • [5] Assessing prostate, bladder and rectal doses during image guided prostate IMRT using kilo voltage cone beam CT
    Varadhan
    Way, S.
    Nisi, K.
    Hui, S.
    MEDICAL PHYSICS, 2007, 34 (06) : 2393 - 2394
  • [6] Study of Variation of Pelvis Positioning for Patients Suffering from Rectal Cancer using Daily Kilo-Voltage Cone Beam CT Images
    Mandal, Sayan
    Veduruparthi, Bijju Kranthi
    Mukherjee, Jayanta
    Das, Partha Pratim
    Mallick, Indranil
    2015 FIFTH NATIONAL CONFERENCE ON COMPUTER VISION, PATTERN RECOGNITION, IMAGE PROCESSING AND GRAPHICS (NCVPRIPG), 2015,
  • [7] Evaluation of kilo-voltage cone beam CT image quality in context to dose re-computation
    Rong, Y.
    Tewatia, D.
    Paliwal, B.
    MEDICAL PHYSICS, 2007, 34 (06) : 2334 - 2334
  • [8] The influence of a dietary protocol on cone beam CT-guided radiotherapy for prostate cancer patients
    Smitsmans, Monique H. P.
    Pos, Floris J.
    de Bois, Josien
    Heemsbergen, Wilma D.
    Sonke, Jan-Jakob
    Lebesque, Joos V.
    van Herk, Marcel
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (04): : 1279 - 1286
  • [9] Validation of bowel and bladder preparation by rectum and bladder variation in prostate radiotherapy based on cone beam CTs
    Huang, Sijuan
    Zhong, Ziyue
    Pang, Yajun
    Zheng, Wanjia
    Liu, Yang
    He, Mengxue
    He, Liru
    Yang, Xin
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2023, 16 (01)
  • [10] COMPARISON OF SETUP ERRORS MEASURED WITH THE KILO-VOLTAGE CONE-BEAM CT AND ELECTRONIC PORTAL-IMAGES FOR BREAST CANCER PATIENTS
    Topolnjak, R.
    Sonke, J. J.
    Minkema, D.
    Remeijer, P.
    Rasch, C.
    van Vliet-Vroegindeweij, C.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S367 - S368