Assessing prostate, bladder and rectal doses during image guided prostate IMRT using kilo voltage cone beam CT

被引:0
|
作者
Varadhan
Way, S.
Nisi, K.
Hui, S.
机构
[1] Minneapolis Radiat Oncol, Robbinsdale, MN USA
[2] Univ Minnesota, Minneapolis, MN USA
关键词
D O I
10.1118/1.2760616
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate dosimetric uncertainties due to interfraction organ variation during Image Guided IMRT using Elekta Synergy System. On board Kilovoltage Cone Beam CT scans were evaluated for prostate, bladder and rectal volume changes and planned dose was compared against the actual delivered dose. Clinical feasibility for an offline correction protocol for an adaptive process was investigated. Methods & Materials: We investigated for five patients the actual dose delivered to prostate, bladder and rectum by using the cone beam CT as the study set and recomputing dose from IMRT fields. In order to do achieve this one full volumetric Cone Beam CT study set was randomly chosen for each patient from each week and thus a total of 9 CT (Week 1 to Week 9) study sets were used for each patient to analyze the prostate, bladder and rectal volume changes and hence their impact on dosimetry. The contoured Cone Beam CT volumes were reviewed by the Radiation Oncologist for accuracy. The CBCT scans were fused with the KV CT scans and the dose was recomputed. Results: KV CBCT was shown to be useful in characterizing Prostate, Bladder and rectal volume changes. There was a large variation in bladder and rectal volumes and hence the constraints defined in RTOG‐0126 protocol varied from week to week. Conclusion: The current work describes an adaptive process for Image Guided Prostate IMRT. Replanning will ultimately allow one to reoptimize the IMRT beams based on the dose variation from original plan. However at this point this process is prohibitively time consuming and for future implementation of adaptive radiotherapy or dose escalation this process needs to be automated with a deformable registration model. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2393 / 2394
页数:2
相关论文
共 50 条
  • [1] Assessing prostate, bladder and rectal doses during image guided radiation therapy - need for plan adaptation?
    Varadhan, Raj
    Hui, Susanta K.
    Way, Sarah
    Nisi, Kurt
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (03): : 56 - 74
  • [2] Evaluation of Cone Beam CT in Prostate IMRT
    Jang, S.
    Hurley, A.
    Cardarelli, G.
    Corrao, A.
    DiPetrillo, T.
    Sternick, E.
    Wazer, D.
    MEDICAL PHYSICS, 2008, 35 (06) : 2812 - +
  • [3] Automated Image Guidance for Prostate IMRT Using Low Dose Cone Beam CT
    Wierzbicki, M.
    Schaly, B.
    Barnett, R.
    MEDICAL PHYSICS, 2009, 36 (09) : 4314 - 4314
  • [4] The influence of the bowel and bladder preparation protocol for radiotherapy of prostate cancer using kilo-voltage cone beam CT: Our experience
    Heng, S. P.
    Low, S. H.
    Sivamany, K.
    INDIAN JOURNAL OF CANCER, 2015, 52 (04) : 639 - +
  • [5] Kilo-voltage cone-beam CT for image-guided radiation therapy
    Sonke, JJ
    Remeijer, P
    Betgen, A
    Lebesque, J
    van Herk, M
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S70 - S70
  • [6] Use of cone-beam CT in prostate IMRT
    Jang, S.
    Hurley, A. A.
    Curran, B. H.
    DiPetrillo, T.
    Cardarelli, G. A.
    Sternick, E. S.
    Wazer, D. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S575 - S575
  • [7] Consistency of cone beam CT-derived bladder volume and inflow during localized prostate cancer IMRT
    Ho, C. J.
    McGarry, C. K.
    Sun, J. Y.
    Lyons, C. A.
    King, R. B.
    Jain, S.
    Hounsell, A. R.
    O'Sullivan, J. M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S643 - S643
  • [8] Image Guided Radiotherapy: Performance of Cone Beam CT Automatic Image Registration of the Prostate
    Sykes, J. R.
    Brettle D, S.
    Magee, D.
    Thwaites, D. I.
    CLINICAL ONCOLOGY, 2011, 23 (03) : S18 - S18
  • [9] Volume and dosimetric analysis of rectum and bladder for prostate carcinoma patients by using kilo voltage cone beam computed tomography (CBCT)
    Venkatesan, K.
    Raphael, C. J.
    Varghese, K. M.
    Gopu, P.
    Sivakumar, S.
    Boban, M.
    Raj, N. A. N.
    Senthilnathan, K.
    Babu, P. Ramesh
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (03): : 557 - 569
  • [10] Influence of volumes of prostate, rectum, and bladder on treatment planning CT on interfraction prostate shifts during ultrasound image-guided IMRT
    Reddy, Nandanuri M. S.
    Nori, Dattatreyudu
    Sartin, William
    Maiorano, Samuel
    Modena, Jennifer
    Mazur, Andrej
    Osian, Adrian
    Sood, Brijmohan
    Ravi, Akkamma
    Sampath, Seshadri
    Lange, Christopher S.
    MEDICAL PHYSICS, 2009, 36 (12) : 5604 - 5611