High-resolution MRI of the wrist and finger joints in patients with rheumatoid arthritis: comparison of 1.5 Tesla and 3.0 Tesla

被引:35
|
作者
Wieners, Gero
Detert, Jacqueline
Streitparth, Florian
Pech, Maciej
Fischbach, Frank
Burmester, Gerd
Ricke, Jens
Backhaus, Marina
Bruhn, Harald
机构
[1] Otto Von Guericke Univ, Dept Radiol & Nucl Med, D-39120 Magdeburg, Germany
[2] Charite Univ Med Berlin, Dept Rheumatol & Clin Immunol, D-10117 Berlin, Germany
[3] Charite Univ Med Berlin, Dept Radiol, D-13353 Berlin, Germany
关键词
rheumatoid arthritis; 3 Tesla MR; OMERACT; RAMRIS;
D O I
10.1007/s00330-006-0539-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The goal of this study was to compare magnetic resonance (MR) image quality at different field strengths for evaluating lesions in wrist and finger joints of patients with rheumatoid arthritis (RA) in order to determine whether the higher field strength provides diagnostic gain. The hand mainly affected in 17 RA patients was examined at 1.5 Tesla (T) and 3.0 T with comparable MR imaging (MRI) protocols. MR images were reviewed twice by two experienced radiologists using the Rheumatoid Arthritis MRI Scoring System (RAMRIS) of the OMERACT (Outcome Measures in Rheumatoid Arthritis Clinical Trials) group. Image quality was rated on a five-point scale using Friedmann's test and Kendall's W-test for statistical analysis. Image comparison revealed better image quality at higher field strength. Image quality of T1-weighted images was rated 14-22% better at 3.0 T compared with 1.5 T by both readers. Moreover, the rating for the T2-weighted-images acquired at 3.0 T was one point better in the five-point scale used. Inter-reader correlation for image quality, bone erosions/defects, edema and synovitis ranged between 0.6 and 0.9 at 3.0 T and between 0.6 and 0.8 at 1.5 T. Intra-reader correlation for these parameters was high at 0.8-1.0. MRI image quality of RA hands is superior at 3.0 T, while an acceptable image quality is achieved at 1.5 T, which improves the evaluation of extent of bone edema, synovitis and identification of small bone erosions.
引用
收藏
页码:2176 / 2182
页数:7
相关论文
共 50 条
  • [31] Fast and quantitative high-resolution magnetic resonance imaging of the optic nerve at 3.0 tesla
    Weigel, M
    Lagrèze, WA
    Lazzaro, A
    Hennig, JG
    Bley, TA
    INVESTIGATIVE RADIOLOGY, 2006, 41 (02) : 83 - 86
  • [32] High-resolution echo-planar fMRI of human visual cortex at 3.0 tesla
    Thulborn, KR
    Chang, SY
    Shen, GX
    Voyvodic, JT
    NMR IN BIOMEDICINE, 1997, 10 (4-5) : 183 - 190
  • [33] Diagnostic performance in T staging for patients with esophagogastric junction cancer using high-resolution MRI: a comparison with conventional MRI at 3 tesla
    Yuan Yuan
    Luguang Chen
    Shengnan Ren
    Zhen Wang
    Yukun Chen
    Aiguo Jin
    Shuai Li
    Xu Fang
    Tiegong Wang
    Yun Bian
    Qingsong Yang
    Chenguang Bai
    Qiang Hao
    Jianping Lu
    Cancer Imaging, 19
  • [34] Diagnostic performance in T staging for patients with esophagogastric junction cancer using high-resolution MRI: a comparison with conventional MRI at 3 tesla
    Yuan, Yuan
    Chen, Luguang
    Ren, Shengnan
    Wang, Zhen
    Chen, Yukun
    Jin, Aiguo
    Li, Shuai
    Fang, Xu
    Wang, Tiegong
    Bian, Yun
    Yang, Qingsong
    Bai, Chenguang
    Hao, Qiang
    Lu, Jianping
    CANCER IMAGING, 2019, 19 (01)
  • [35] USING 3 TESLA MRI WITH A HIGH-RESOLUTION 16-CHANNEL HAND COIL TO DIFFERENTIATE BETWEEN RHEUMATOID AND PSORIATIC ARTHRITIS: A PILOT STUDY
    Sewerin, P.
    Abrar, D.
    Lautwein, A.
    Vordenbaeumen, S.
    Brinks, R.
    Goertz, C.
    Frenken, M.
    Schneider, M.
    Ostendorf, B.
    Schleich, C.
    ANNALS OF THE RHEUMATIC DISEASES, 2020, 79 : 1408 - 1409
  • [36] High-resolution magnetic resonance imaging at 1.5 Tesla for endolymphatic hydrops in the cochlea in vivo
    Niyazov, DM
    Andrews, JC
    Sinha, S
    Lufkin, RB
    RADIOLOGY, 2000, 217 : 175 - 176
  • [37] Correlation of in vivo and cadaver high-resolution hippocampal MRI anatomy at 8 Tesla
    Chakeres, DW
    Scharre, D
    Beversdorf, D
    Santi, M
    Dashner, R
    Kangarlu, A
    RADIOLOGY, 2001, 221 : 345 - 345
  • [38] Vascular compression in glossopharyngeal neuralgia: demonstration by high-resolution MRI at 3 tesla
    Fischbach, F
    Lehmann, TN
    Ricke, J
    Bruhn, H
    NEURORADIOLOGY, 2003, 45 (11) : 810 - 811
  • [39] Tandem and Ovoids Brachytherapy for Cervical Cancer When Evaluated by High Resolution (3.0 Tesla) MRI
    Kim, Y.
    Xia, J.
    Sun, W.
    Bhatia, S. K.
    Jacbson, G. M.
    MEDICAL PHYSICS, 2010, 37 (06) : 3348 - +
  • [40] Vascular compression in glossopharyngeal neuralgia: demonstration by high-resolution MRI at 3 tesla
    F. Fischbach
    T. N. Lehmann
    J. Ricke
    H. Bruhn
    Neuroradiology, 2003, 45 : 810 - 811