摘要
The objective of this work was to fabricate and characterize a new X-ray imaging detector with micrometre-scale pixel dimensions (7.8 mu m) and high detection efficiency for hard X-ray energies above 20 keV. A key technology component consists of a monolithic hybrid detector built by direct deposition of an amorphous selenium film on a custom designed CMOS readout integrated circuit. Characterization was carried out at the synchrotron beamline 1-BM-B at the Advanced Photon Source of Argonne National Laboratory. The direct conversion detector demonstrated micrometre-scale spatial resolution with a 63 keV modulation transfer function of 10% at Nyquist frequency. In addition, spatial resolving power down to 8 mu m was determined by imaging a transmission bar target at 21 keV. X-ray signal linearity, responsivity and lag were also characterized in the same energy range. Finally, phase contrast edge enhancement was observed in a phase object placed in the beam path. This amorphous selenium/CMOS detector technology can address gaps in commercially available X-ray detectors which limit their usefulness for existing synchrotron applications at energies greater than 50 keV; for example, phase contrast tomography and high-resolution imaging of nanoscale lattice distortions in bulk crystalline materials using Bragg coherent diffraction imaging. The technology will also facilitate the creation of novel synchrotron imaging applications for X-ray energies at or above 20 keV.
引用
收藏
页码:1081 / 1089
页数:9
相关论文
共 50 条
  • [31] The high-energy detector of the New Hard X-ray Mission (NHXM): design concept
    Bellazzini, R.
    Brez, A.
    Minuti, M.
    Pinchera, M.
    Spandre, G.
    Argan, A.
    Catalano, O.
    Costa, E.
    Fiorini, C.
    Malaguti, G.
    Pareschi, G.
    Tagliaferri, G.
    Uslenghi, M.
    SPACE TELESCOPES AND INSTRUMENTATION 2010: ULTRAVIOLET TO GAMMA RAY, 2010, 7732
  • [32] Ge pixel array detector for high throughput X-ray spectroscopy
    Oyanagi, H
    Fonne, C
    Gutknecht, D
    Dressler, P
    Henck, R
    Lampert, MO
    Ogawa, S
    Kasai, K
    Mohamed, SB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (1-2): : 340 - 344
  • [33] High resolution X-ray spectroscopy using a GaAs pixel detector
    Owens, A
    Bavdaz, M
    Peacock, A
    Andersson, H
    Nenonen, S
    Krumrey, M
    Puig, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 479 (2-3): : 531 - 534
  • [34] Capability of the ASTRO-E Hard X-ray Detector for high-energy transients and γ-ray bursts
    Terada, Y
    Yamaoka, K
    Kokubun, M
    Kotoku, J
    Mizuno, T
    Kataoka, J
    Takahasi, T
    Murakami, T
    Makishima, K
    Kamae, T
    FIFTH COMPTON SYMPOSIUM, 2000, 510 : 667 - 670
  • [35] Large area direct X-ray conversion detector for protein crystallography
    Sultana, Afrin
    Karim, K. S.
    Rowlands, J. A.
    2008 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-4, 2008, : 947 - 950
  • [36] X-ray detection method for the direct-conversion plasma detector
    Kang, Jungwon
    Shin, Hyungsup
    Lee, Sangjun
    Lee, Kisung
    Lee, Hakjae
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XII, 2010, 7805
  • [37] CMOS direct conversion X-ray detector coupled with fluorinated liquid
    ShiHua Liu
    ChaoSong Gao
    Xin Zhang
    XiangMing Sun
    Meng Wu
    ZhiHui Han
    Tong Wan
    YongShuai Ge
    Nuclear Science and Techniques, 2025, 36 (01) : 5 - 14
  • [38] Direct-conversion x-ray imaging detector improvements and observations
    Lee, DLY
    Lui, C
    Golden, KP
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS V, 2003, 5199 : 162 - 166
  • [39] Cmos direct conversion X-ray detector coupled with fluorinated liquid
    Liu, Shi-Hua
    Gao, Chao-Song
    Zhang, Xin
    Sun, Xiang-Ming
    Wu, Meng
    Han, Zhi-Hui
    Wan, Tong
    Ge, Yong-Shuai
    NUCLEAR SCIENCE AND TECHNIQUES, 2025, 36 (01)
  • [40] Energy discrimination with an X-ray pixel detector - a Monte-Carlo simulation
    Pedersen, F
    Ronnqvist, C
    Fransson, K
    Gustafsson, L
    Kullander, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (03): : 443 - 447