Corrosion behavior of nitrogen stainless steel in Ringer's solution

被引:0
|
作者
Ilieva, G. P. [1 ]
Loukaycheva, M. H. [2 ]
Tzaneva, B. R. [2 ]
Gekova, L. T. [3 ]
Fachikov, L. B. [1 ]
机构
[1] Univ Chem Technol & Met, 8 Kliment Ohridski Blvd, BU-1756 Sofia, Bulgaria
[2] Tech Univ Sofia, 8 Kliment Ohridski Blvd, Sofia 1756, Bulgaria
[3] BAS, Inst Met Sci Equipment & Technol Acad A Balevski, Hydroaerodynam Ctr, 67 Shipchenski Prohod Str, Sofia 1574, Bulgaria
来源
关键词
stainless steel; HNS; nitrogen; Ringer solution; potentiodynamic polarization; potentiostatic polarization; IN-VITRO;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The implant materials used in medicine are made from different materials and the principle requirement to each material used is its biocompatibility. This work reports preliminary results regarding assessment of high nitrogen stainless steel (HNS) Cr18Mn12N as an implant material replacing of the common Ni containing stainless steels which are toxic. Short -time (for 1 h) and long -time (for up to 220 h) open circuit potential measurements were performed as well as potentiodynamic and potentiostatic studies in Ringer's solution at 37 degrees C. The effect of the preliminary treatment was also considered. After the potentiostatic tests optical and scanning electron microscopies were used to determine the character of the corrosion attack. The surface of the samples was examined and by EDX analysis in order to find out the corrosion products content. Based on the obtained results it can be concluded that the HNS steel exhibits better corrosion resistance in Ringer's solution.
引用
收藏
页码:66 / 72
页数:7
相关论文
共 50 条
  • [41] CORROSION FATIGUE CRACK INITIATION BEHAVIOR OF 316L STAINLESS STEEL IN HANK’S SOLUTION
    J.H. Xie
    Y.S. Wu
    J.Q. He
    X.Z.Yang and R.Z. Zhu (Department of Surface Science & Corrosion Engineering
    Acta Metallurgica Sinica(English Letters), 1996, (05) : 333 - 337
  • [42] Corrosion resistance of nickel-free austenitic stainless steels and their nanocomposites with hydroxyapatite in Ringer's solution
    Tulinski M.
    Jurczyk M.
    Materials Science Forum, 2011, 674 : 159 - 163
  • [43] Influence of Cold Deformation and Phase Transformation on the Electrochemical Corrosion Behavior of Nitrogen-Alloyed Stainless Steel in Chloride Solution
    Tuchscheerer, Friedrich
    Krueger, Lutz
    STEEL RESEARCH INTERNATIONAL, 2017, 88 (09)
  • [44] Effect of Substrate Preparation and the Conversion Coating on the Corrosion Resistance in Ringer's Solution of 304L Stainless Steel Coated with Alumina Film
    Pereira, Carlos M. S.
    Silva, Gustavo F.
    Diniz, Marilia G.
    Silva, Camila S.
    Braga, Antonio V. C.
    de Senna, Lilian F.
    MATERIALS RESEARCH-IBERO-AMERICAN JOURNAL OF MATERIALS, 2024, 27
  • [45] Corrosion behavior of deformed low-nickel stainless steel in groundwater solution
    Feng, Xingguo
    Zhang, Xiangying
    Xu, Yiwen
    Shi, Ruilong
    Lu, Xiangyu
    Zhang, Leyuan
    Zhang, Jing
    Chen, Da
    ENGINEERING FAILURE ANALYSIS, 2019, 98 : 49 - 57
  • [47] Corrosion fatigue behavior of duplex stainless steel in 3.5% sodium chloride solution
    Abubakir, SH
    Wu, YS
    Ding, BF
    Li, JQ
    Cao, B
    JOURNAL OF UNIVERSITY OF SCIENCE AND TECHNOLOGY BEIJING, 2001, 8 (02): : 133 - 136
  • [48] Corrosion Pit to Crack Transition Behavior of 304 Stainless Steel in a Chloride Solution
    Pal S.
    Bhadauria S.S.
    Kumar P.
    Journal of Bio- and Tribo-Corrosion, 2022, 8 (1)
  • [49] Effect of acetic NaF solution on the corrosion behavior of stainless steel orthodontic brackets
    Jang, Hee-Song
    Son, Woo-Sung
    Park, Soo-Byung
    Kim, Hyung-Il
    Kwon, Yong Hoon
    DENTAL MATERIALS JOURNAL, 2006, 25 (02) : 339 - 344
  • [50] CORROSION BEHAVIOR OF TYPE 304 STAINLESS STEEL IN ACETIC ACID SOLUTION.
    Sekine, Isao
    Koeda, Masahiro
    Boshoku gijutsu, 1984, 33 (09): : 500 - 503