Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast

被引:123
|
作者
Albrecht, Moritz H. [1 ]
Scholtz, Jan-Erik [1 ]
Huesers, Kristina [1 ]
Beeres, Martin [1 ]
Bucher, Andreas M. [1 ]
Kaup, Moritz [1 ]
Martin, Simon S. [1 ]
Fischer, Sebastian [1 ]
Bodelle, Boris [1 ]
Bauer, Ralf W. [1 ]
Lehnert, Thomas [1 ]
Vogl, Thomas J. [1 ]
Wichmann, Julian L. [1 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
关键词
Monoenergetic plus; Monochromatic imaging; Computed tomography angiography; Image quality; Dual-energy CT; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; REDUCED IODINE LOAD; CHEST CT; QUALITY; NOISE;
D O I
10.1007/s00330-015-3970-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare quantitative image quality parameters in abdominal dual-energy computed tomography angiography (DE-CTA) using an advanced image-based (Mono+) reconstruction algorithm for virtual monoenergetic imaging and standard DE-CTA. Fifty-five patients (36 men; mean age, 64.2 +/- 12.7 years) who underwent abdominal DE-CTA were retrospectively included. Mono + images were reconstructed at 40, 50, 60, 70, 80, 90 and 100 keV levels and as standard linearly blended M_0.6 images (60 % 100 kV, 40 % 140 kV). The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of the common hepatic (CHA), splenic (SA), superior mesenteric (SMA) and left renal arteries (LRA) were objectively measured. Mono+ DE-CTA series showed a statistically superior CNR for 40, 50, 60, 70 and 80 keV (P < 0.031) compared to M_0.6 images for all investigated arteries except SMA at 80 keV (P = 0.08). CNR at 40 keV revealed a mean relative increase of 287.7 % compared to linearly blended images among all assessed arteries (P < 0.001). SNR of Mono+ images was consistently significantly higher at 40, 50, 60 and 70 keV compared to M_0.6 for CHA and SA (P < 0.009). Compared to linearly blended images, Mono+ reconstructions at low keV levels of abdominal DE-CTA datasets significantly improve quantitative image quality. aEuro cent Mono+ combines increased attenuation with reduced image noise compared to standard DE-CTA. aEuro cent Mono+ shows superior contrast-to-noise ratios at low keV compared to linearly-blended images. aEuro cent Contrast-to-noise ratio in monoenergetic DE-CTA peaks at 40 keV. aEuro cent Mono+ reconstructions significantly improve quantitative image quality at low keV levels.
引用
收藏
页码:1863 / 1870
页数:8
相关论文
共 50 条
  • [1] Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast
    Moritz H. Albrecht
    Jan-Erik Scholtz
    Kristina Hüsers
    Martin Beeres
    Andreas M. Bucher
    Moritz Kaup
    Simon S. Martin
    Sebastian Fischer
    Boris Bodelle
    Ralf W. Bauer
    Thomas Lehnert
    Thomas J. Vogl
    Julian L. Wichmann
    European Radiology, 2016, 26 : 1863 - 1870
  • [2] Optimization of Kiloelectron Volt Settings in Cerebral and Cervical Dual-energy CT Angiography Determined with Virtual Monoenergetic Imaging
    Schneider, David
    Apfaltrer, Paul
    Sudarski, Sonja
    Nance, John W., Jr.
    Haubenreisser, Holger
    Fink, Christian
    Schoenberg, Stefan O.
    Henzler, Thomas
    ACADEMIC RADIOLOGY, 2014, 21 (04) : 431 - 436
  • [3] Evaluation of different keV-settings in dual-energy CT angiography of the aorta using advanced image-based virtual monoenergetic imaging
    Martin Beeres
    Jesko Trommer
    Claudia Frellesen
    Nour-Eldin A. Nour-Eldin
    Jan E. Scholtz
    Eva Herrmann
    Thomas J. Vogl
    Julian L. Wichmann
    The International Journal of Cardiovascular Imaging, 2016, 32 : 137 - 144
  • [4] Evaluation of different keV-settings in dual-energy CT angiography of the aorta using advanced image-based virtual monoenergetic imaging
    Beeres, Martin
    Trommer, Jesko
    Frellesen, Claudia
    Nour-Eldin, Nour-Eldin A.
    Scholtz, Jan E.
    Herrmann, Eva
    Vogl, Thomas J.
    Wichmann, Julian L.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (01): : 137 - 144
  • [5] Virtual Monoenergetic Dual-Energy Computed Tomography Optimization of Kiloelectron Volt Settings in Head and Neck Cancer
    Wichmann, Julian L.
    Noeske, Eva-Maria
    Kraft, Johannes
    Burck, Iris
    Wagenblast, Jens
    Eckardt, Anne
    Frellesen, Claudia
    Kerl, J. Matthias
    Bauer, Ralf W.
    Bodelle, Boris
    Lehnert, Thomas
    Vogl, Thomas J.
    Schulz, Boris
    INVESTIGATIVE RADIOLOGY, 2014, 49 (11) : 735 - 741
  • [6] Optimization of window settings for standard and advanced virtual monoenergetic imaging in abdominal dual-energy CT angiography
    Caruso, Damiano
    Parinella, Ashley H.
    Schoepf, U. Joseph
    Stroebel, Maxwell H.
    Mangold, Stefanie
    Wichmann, Julian L.
    Varga-Szemes, Akos
    Ball, B. Devon, Jr.
    De Santis, Domenico
    Laghi, Andrea
    De Cecco, Carlo N.
    ABDOMINAL RADIOLOGY, 2017, 42 (03) : 772 - 780
  • [7] Optimization of window settings for standard and advanced virtual monoenergetic imaging in abdominal dual-energy CT angiography
    Damiano Caruso
    Ashley H. Parinella
    U. Joseph Schoepf
    Maxwell H. Stroebel
    Stefanie Mangold
    Julian L. Wichmann
    Akos Varga-Szemes
    B. Devon Ball
    Domenico De Santis
    Andrea Laghi
    Carlo N. De Cecco
    Abdominal Radiology, 2017, 42 : 772 - 780
  • [8] Phantom-based optimization of virtual monoenergetic image reconstruction in dual-energy CT
    Richter, Anne
    Razinskas, Gary
    Weick, Stefan
    Lutyj, Paul
    Kraft, Johannes
    Wittig-Sauerwein, Andrea
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3848 - S3849
  • [9] Advanced virtual monoenergetic images: improving the contrast of dual-energy CT pulmonary angiography
    Meier, A.
    Wurnig, M.
    Desbiolles, L.
    Leschka, S.
    Frauenfelder, T.
    Alkadhi, H.
    CLINICAL RADIOLOGY, 2015, 70 (11) : 1244 - 1251
  • [10] Noise-optimized virtual monoenergetic dual-energy computed tomography: optimization of kiloelectron volt settings in patients with gastrointestinal stromal tumors
    Simon S. Martin
    Sophia Pfeifer
    Julian L. Wichmann
    Moritz H. Albrecht
    Doris Leithner
    Lukas Lenga
    Jan-Erik Scholtz
    Thomas J. Vogl
    Boris Bodelle
    Abdominal Radiology, 2017, 42 : 718 - 726