Use of automated blood pressure measurements in clinical trials and registration studies: data from the VALTOP Study

被引:14
|
作者
Mengden, Thomas [1 ]
Asmar, Roland [2 ]
Kandra, Albert [3 ]
Di Giovanni, Robert [3 ]
Brudi, Philip [3 ]
Parati, Gianfranco [4 ]
机构
[1] Ctr Vasc Med, D-61231 Bad Nauheim, Germany
[2] Inst CardioVasc, Paris, France
[3] Novartis Pharma AG, Basel, Switzerland
[4] Univ Milano Bicocca, Dept Clin Med & Prevent, Milan, Italy
关键词
clinical trials; electronic blood pressure measurement; observer bias; professional devices; registration studies; HYPERTENSIVE PATIENTS; DIGIT PREFERENCE; EFFICACY; ERROR;
D O I
10.1097/MBP.0b013e328339d516
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background Auscultatory measurement of office blood pressure (BP) by mercury sphygmomanometers (AuscBPM) is still the gold standard in clinical trials and registration studies for antihypertensive drugs. The increasing availability of accurate automated oscillometric BP measuring devices has offered new perspectives in this field, although their usefulness in drug studies has not been systematically tested yet. Methods During the course of Valsartan 320mg EU Registration Study we used an electronic automated oscillometric BP measuring device (eBPM) as an alternative to conventional AuscBPM. Altogether 3776 patients were randomized into a double-blinded actively controlled parallel group study in 303 centers, and 54 422 BP readings were recorded by the validated, electronic, automated oscillometric device OMRON 705IT with digital printouts. Terminal digit preference and preference at therapeutic cutoff points were evaluated. The data were compared with the results of an earlier valsartan study similar in design but based on conventional AuscBPM. Furthermore, based on a simulation, four strategies for automated BP measurement with varying number of office readings (3-5) were analyzed to define an optimal method to collect BP at office visits. Results eBPM eliminated terminal digit preference and dramatically reduced preferences for therapeutic cutoff points as compared with earlier valsartan trials with conventional AuscBPM. However, even with eBPM a minor bias with the therapeutic cutoff value was observed probably because of an observer bias during data documentation. The within-patient variability of three measurements sequentially taken at each visit was similar to other strategies including more measurements. Conclusion On the basis of our data, we suggest that eBPM is a suitable alternative to AuscBPM in clinical trials and registration studies, and may carry specific advantages. Automatic data transfer of recorded values to electronic patient files may further minimize observer bias. Manufacturers should consider such findings for the development of professional devices. Blood Press Monit 15: 188-194 (C) 2010 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:188 / 194
页数:7
相关论文
共 50 条
  • [21] Levofloxacin safety: data from clinical trials and pharmacovigilance studies
    Carbon, C
    [J]. THERAPIE, 2001, 56 (01): : 35 - 40
  • [22] Analysing survival data from clinical trials and observational studies
    Roddam, AW
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES A-STATISTICS IN SOCIETY, 2005, 168 : 463 - 463
  • [23] Availability and Use of Shared Data From Cardiometabolic Clinical Trials
    Vaduganathan, Muthiah
    Nagarur, Amulya
    Qamar, Arman
    Patel, Ravi B.
    Navar, Ann Marie
    Peterson, Eric D.
    Bhatt, Deepak L.
    Fonarow, Gregg C.
    Yancy, Clyde W.
    Butler, Javed
    [J]. CIRCULATION, 2018, 137 (09) : 938 - 947
  • [24] Secure use of individual patient data from clinical trials
    Vallance, Patrick
    Chalmers, Iain
    [J]. LANCET, 2013, 382 (9898): : 1073 - 1074
  • [25] The effects of blood pressure reduction on cognitive function: a review of effects based on pooled data from clinical trials
    Birns, Jonathan
    Morris, Robin
    Donaldson, Nora
    Kalra, Lalit
    [J]. JOURNAL OF HYPERTENSION, 2006, 24 (10) : 1907 - 1914
  • [26] Drug Use and Low Blood Pressure in the ElderlyA Study of Data from the Kungsholmen Project
    Galina Passare
    Zhenchao Guo
    Bengt Winblad
    Johan Fastbom
    [J]. Clinical Drug Investigation, 1998, 15 : 497 - 506
  • [27] VARIABILITY AND RELIABILITY OF BLOOD-PRESSURE MEASUREMENTS IN ANTI-HYPERTENSIVE CLINICAL-TRIALS
    WEINSTEIN, J
    FISHER, AC
    HAMOT, HB
    [J]. CLINICAL RESEARCH, 1978, 26 (03): : A595 - A595
  • [28] Drug use and low blood pressure in the elderly - A study of data from the Kungsholmen Project
    Passare, G
    Guo, ZC
    Winblad, B
    Fastbom, J
    [J]. CLINICAL DRUG INVESTIGATION, 1998, 15 (06) : 497 - 506
  • [29] Accuracy of abbreviated protocols for unattended automated office blood pressure measurements, a retrospective study
    Vischer, Annina S.
    Hug, Rebecca
    Socrates, Thenral
    Meienberg, Andrea
    Mayr, Michael
    Burkard, Thilo
    [J]. PLOS ONE, 2021, 16 (03):
  • [30] Automated Auscultatory Blood Pressure Measurements using Korotkoff Sounds Detection: A Preliminary Study
    Naufal, Dziban
    Noor, Azizah Syifalianti
    Khalil, Muhammad Yusri
    Rajab, Tati Erawati
    Setiawan, Agung Wahyu
    [J]. PROCEEDINGS OF THE 2019 6TH INTERNATIONAL CONFERENCE ON INSTRUMENTATION, CONTROL, AND AUTOMATION (ICA), 2019, : 71 - 76