Correlation of respiratory changes in lung density on dynamic chest radiographs with changes in the CT value: A computational phantom study

被引:0
|
作者
Sugiura, Teruyo [1 ]
Tanaka, Rie [1 ]
Segars, William P. [2 ]
Abadi, Ehsan [2 ]
Samei, Ehsan [2 ]
机构
[1] Kanazawa Univ, Kanazawa, Ishikawa 9200942, Japan
[2] Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
关键词
Dynamic chest radiography; XCAT phantom; Computed Tomography; pixel value; CT value;
D O I
10.1117/12.2579973
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Pulmonary impairments are observed as decreased changes in lung density during respiration on dynamic chest radiographs (DCR). To facilitate pulmonary function evaluation based on DCR, the present study was conducted to correlate respiratory changes in pixel values (pixel values) on DCR images with those in computed tomography (CT) values (Delta CT values) using four-dimensional extended cardiac-torso (XCAT) phantoms. Twenty XCAT phantoms with forced breathing with/without chest wall motion were generated, and then, were projected using an X-ray simulator. Delta pixel values and Delta CT values on respiration were calculated on the simulated projection and CT images, respectively, to create a conversion table. The equation (regression line) of the relationship between the Delta pixel values and Delta CT values in the lung field was calculated, and statistical analysis was performed to test whether there was a significant difference in the inclination of the regression line (P < 0.05) in terms of physique, sex, and breathing manner. There was a significant difference in the inclination of the regression lines between males and females, with and without chest wall motion. We developed a conversion table from Delta pixel values to Delta CT values in the lung field. Our results demonstrated the feasibility of the quantitative evaluation of pulmonary function based on Delta pixel values on DCR. It would be helpful to provide a better understanding of the pulmonary function and conditions based on Delta pixel values while considering Delta CT values.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Dynamic changes in lung water density and volume following supine body positioning
    Goodhart, Thomas
    Seres, Peter
    Grenier, Justin
    Keen, Christopher
    Stobbe, Rob
    Thompson, Richard B.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (06) : 2612 - 2620
  • [32] Ventilatory impairment detection based on distribution of respiratory-induced changes in pixel values in dynamic chest radiography: a feasibility study
    Tanaka, Rie
    Sanada, Shigeru
    Fujimura, Masaki
    Yasui, Masahide
    Tsuji, Shiro
    Hayashi, Norio
    Okamoto, Hiroyuki
    Nanbu, Yuko
    Matsui, Osamu
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2011, 6 (01) : 103 - 110
  • [33] Ventilatory impairment detection based on distribution of respiratory-induced changes in pixel values in dynamic chest radiography: a feasibility study
    Rie Tanaka
    Shigeru Sanada
    Masaki Fujimura
    Masahide Yasui
    Shiro Tsuji
    Norio Hayashi
    Hiroyuki Okamoto
    Yuko Nanbu
    Osamu Matsui
    International Journal of Computer Assisted Radiology and Surgery, 2011, 6 : 103 - 110
  • [34] Value of dynamic respiratory changes in left and right ventricular pressures for the diagnosis of constrictive pericarditis
    Hurrell, DG
    Nishimura, RA
    Higano, ST
    Appleton, CP
    Danielson, GK
    Holmes, DR
    Tajik, AJ
    CIRCULATION, 1996, 93 (11) : 2007 - 2013
  • [35] PULMONARY-EDEMA - A CT STUDY OF REGIONAL CHANGES IN LUNG DENSITY FOLLOWING OLEIC-ACID INJURY
    HEDLUND, LW
    EFFMANN, EL
    BATES, WM
    BECK, JW
    GOULDING, PL
    PUTMAN, CE
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (05) : 939 - 946
  • [36] A prospective study of radiation induced lung InJury: Measured changes in pulmonary symptoms, physiologic function and CT density
    Lee, JW
    Cheung, P
    Rakovitch, E
    Tirona, R
    Ravi, A
    Mah, K
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S390 - S391
  • [37] Computer-assisted quantification of lung tumors in respiratory gated PET/CT images: phantom study
    Jiali Wang
    Misael del Valle
    Mohammed Goryawala
    Juan M. Franquiz
    Anthony J. Mcgoron
    Medical & Biological Engineering & Computing, 2010, 48 : 49 - 58
  • [38] Correlation of Survival Rates with CT Texture Changes After Radiation Therapy for Lung Cancer
    Paul, J.
    Zheng, C.
    Hao, Y.
    Gore, E. M.
    Li, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : S185 - S185
  • [39] Computer-assisted quantification of lung tumors in respiratory gated PET/CT images: phantom study
    Wang, Jiali
    del Valle, Misael
    Goryawala, Mohammed
    Franquiz, Juan M.
    Mcgoron, Anthony J.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (01) : 49 - 58
  • [40] Time evolution of regional CT density changes in normal lung after IMRT for NSCLC
    Bernchou, Uffe
    Schytte, Tine
    Bertelsen, Anders
    Bentzen, Soren M.
    Hansen, Olfred
    Brink, Carsten
    RADIOTHERAPY AND ONCOLOGY, 2013, 109 (01) : 89 - 94