Development of rapid and high-throughput LC-MS/MS method for quantification of olprinone in rabbit plasma

被引:0
|
作者
Kertys, Martin [1 ,2 ]
Kosutova, Petra [2 ,3 ]
Mokra, Daniela [2 ,3 ]
Mokry, Juraj [1 ,2 ]
机构
[1] Comenius Univ, Jessenius Fac Med Martin, Dept Pharmacol, Mala Hora 4C, Martin 03601, Slovakia
[2] Comenius Univ, Jessenius Fac Med Martin, Biomed Ctr Martin, Martin, Slovakia
[3] Comenius Univ, Jessenius Fac Med Martin, Dept Physiol, Martin, Slovakia
关键词
liquid chromatography; mass spectrometry; olprinone; plasma; rabbit; PHOSPHODIESTERASE-III INHIBITOR; HYDROCHLORIDE;
D O I
10.1002/bmc.4620
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, highly sensitive and rapid method for quantification of olprinone (phosphodiesterase 3 inhibitor) in rabbit plasma using liquid chromatography-tandem mass spectrometry with electrospray was developed. An aliquot of 50 mu L of plasma sample was cleaned up and extracted using Ostro (TM) 96-well plate followed by dilution. Chromatographic separation of olprinone and olprinone-d3 was carried out on a CORTECS (R) T3 column within 3 min. Detection was achieved using a triple quadrupole mass spectrometer employing electrospray ionization operated in positive ion multiple reaction monitoring mode using the transitions m/z 251.07 -> m/z 155.06 and m/z 254.21 -> m/z 158.10 for olprinone and olprinone-d3, respectively. The method was validated according to US Food and Drug Administration guideline for bioanalytical methods, and showed excellent linearity in the range 10.0-2000.0 ng/mL with coefficient of determination >0.99. The intra- and inter-day precisions (CV) were <5.1% and the accuracies were within the range 99.7-103.2% at all quality control concentrations. Furthermore, olprinone was stable under various stability conditions. The developed method was used for quantification of olprinone in rabbit plasma after its intravenous administration at the dose of 1 mg/kg in order to better understand the metabolism of olprinone in a rabbit model of lung injury.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Development of an LC-MS/MS method for the simultaneous quantification of aripiprazole and dehydroaripiprazole in human plasma
    Song, Min
    Xu, Xinxin
    Hang, Taijun
    Wen, Aidong
    Yang, Lin
    ANALYTICAL BIOCHEMISTRY, 2009, 385 (02) : 270 - 277
  • [42] Development and validation of a LC-MS/MS method for the quantification of tenofovir and emtricitabine in seminal plasma
    Illamola, S. M.
    Valade, E.
    Hirt, D.
    Dulioust, E.
    Zheng, Y.
    Wolf, J. P.
    Treluyer, J. M.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1033 : 234 - 241
  • [43] Development and validation of an improved high-throughput method for the determination of anastrozole in human plasma by LC-MS/MS and atmospheric pressure chemical ionization
    Apostolou, Constantinos
    Dotsikas, Yannis
    Kousoulos, Constantinos
    Loukas, Yannis L.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (03) : 853 - 859
  • [44] Time-Optimized Isotope Ratio LC-MS/MS for High-Throughput Quantification of Primary Metabolites
    Guder, Jan Christopher
    Schramm, Thorben
    Sander, Timur
    Link, Hannes
    ANALYTICAL CHEMISTRY, 2017, 89 (03) : 1624 - 1631
  • [45] A rapid LC-MS/MS method for multi-class identification and quantification A rapid LC-MS/MS method for multi-class identification and quantification of cyanotoxins of cyanotoxins
    Jacinavicius, Fernanda Rios
    Campos, Thaissa Giovanna Valverde
    Passos, Larissa Souza
    Pinto, Ernani
    Geraldes, Vanessa
    TOXICON, 2023, 234
  • [46] High-throughput method for the determination of residues of β-lactam antibiotics in bovine milk by LC-MS/MS
    Jank, Louise
    Martins, Magda Targa
    Arsand, Juliana Bazzan
    Hoff, Rodrigo Barcellos
    Barreto, Fabiano
    Pizzolato, Tania Mara
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2015, 32 (12): : 1992 - 2001
  • [47] Metaxalone estimation in biological matrix using high-throughput LC-MS/MS bioanalytical method
    Goswami, Dipanjan
    Saha, Arabinda
    Gurule, Sanjay
    Khuroo, Arshad
    Monif, Tausif
    Vats, Poonam
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 902 : 132 - 136
  • [48] Development and validation of a high-throughput LC-MS/MS assay for routine measurement of molecular ceramides
    Kauhanen, Dimple
    Sysi-Aho, Marko
    Koistinen, Kaisa M.
    Laaksonen, Reijo
    Sinisalo, Juha
    Ekroos, Kim
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (13) : 3475 - 3483
  • [49] High-throughput LC-MS/MS method for monitoring sirolimus and everolimus in the routine clinical laboratory
    Ivanova, Mariela
    Artusi, Carlo
    Polo, Giulia
    Zaninotto, Martina
    Plebani, Mario
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (07) : 1151 - 1158
  • [50] High-Throughput Ultra-Performance LC-MS-MS Method for Analysis of Diclofenac Sodium in Rabbit Plasma
    Alam, Mohd Aftab
    Al-Jenoobi, Fahad I.
    Al-Mohizea, Abdullah M.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (01) : 47 - 53