Development of rapid and high-throughput LC-MS/MS method for quantification of olprinone in rabbit plasma

被引:0
|
作者
Kertys, Martin [1 ,2 ]
Kosutova, Petra [2 ,3 ]
Mokra, Daniela [2 ,3 ]
Mokry, Juraj [1 ,2 ]
机构
[1] Comenius Univ, Jessenius Fac Med Martin, Dept Pharmacol, Mala Hora 4C, Martin 03601, Slovakia
[2] Comenius Univ, Jessenius Fac Med Martin, Biomed Ctr Martin, Martin, Slovakia
[3] Comenius Univ, Jessenius Fac Med Martin, Dept Physiol, Martin, Slovakia
关键词
liquid chromatography; mass spectrometry; olprinone; plasma; rabbit; PHOSPHODIESTERASE-III INHIBITOR; HYDROCHLORIDE;
D O I
10.1002/bmc.4620
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, highly sensitive and rapid method for quantification of olprinone (phosphodiesterase 3 inhibitor) in rabbit plasma using liquid chromatography-tandem mass spectrometry with electrospray was developed. An aliquot of 50 mu L of plasma sample was cleaned up and extracted using Ostro (TM) 96-well plate followed by dilution. Chromatographic separation of olprinone and olprinone-d3 was carried out on a CORTECS (R) T3 column within 3 min. Detection was achieved using a triple quadrupole mass spectrometer employing electrospray ionization operated in positive ion multiple reaction monitoring mode using the transitions m/z 251.07 -> m/z 155.06 and m/z 254.21 -> m/z 158.10 for olprinone and olprinone-d3, respectively. The method was validated according to US Food and Drug Administration guideline for bioanalytical methods, and showed excellent linearity in the range 10.0-2000.0 ng/mL with coefficient of determination >0.99. The intra- and inter-day precisions (CV) were <5.1% and the accuracies were within the range 99.7-103.2% at all quality control concentrations. Furthermore, olprinone was stable under various stability conditions. The developed method was used for quantification of olprinone in rabbit plasma after its intravenous administration at the dose of 1 mg/kg in order to better understand the metabolism of olprinone in a rabbit model of lung injury.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] A rapid LC-MS/MS Method for the Quantification of Cyclosporine A in Rabbit Whole Blood and Plasma
    Huang, Yi
    Xu, Zhi-sheng
    Zheng, Shuang-li
    Hou, Yao
    LATIN AMERICAN JOURNAL OF PHARMACY, 2013, 32 (07): : 1035 - 1041
  • [2] High-Throughput LC-MS/MS Method for Direct Quantification of Glucuronidated, Sulfated, and Free Enterolactone in Human Plasma
    Norskov, Natalja P.
    Kyro, Cecilie
    Olsen, Anja
    Tjonneland, Anne
    Knudsen, Knud Erik Bach
    JOURNAL OF PROTEOME RESEARCH, 2016, 15 (03) : 1051 - 1058
  • [3] Development of simple and rapid method for Emicizumab quantification by LC-MS/MS in human plasma
    Josset, Laurie
    Hodin, Sophie
    Delinger, Sandrine
    Marin, Clemence
    Dargaud, Yesim
    Delavenne, Xavier
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 223
  • [4] Fast LC for high-throughput LC-MS
    Wehr, T
    LC GC NORTH AMERICA, 2003, : 75 - 78
  • [5] Fast LC for high-throughput LC-MS
    Wehr, T
    LC GC NORTH AMERICA, 2002, 20 (01) : 40 - +
  • [6] Ultra-fast Generic LC-MS/MS Method for High-Throughput Quantification in Drug Discovery
    Kim, So-Hee
    Yoo, Hye Hyun
    Cha, Eun-Ju
    Jeong, Eun Sook
    Kim, Ho Jun
    Kim, Dong Hyun
    Lee, Jaeick
    MASS SPECTROMETRY LETTERS, 2013, 4 (03) : 47 - 50
  • [7] DEVELOPMENT OF HIGH THROUGHPUT LC-MS/MS ASSAYS FOR NUTRITIONAL BIOMARKER QUANTIFICATION
    Mawson, D.
    Marrs, K.
    Teale, P.
    Grace, P.
    ANNALS OF NUTRITION AND METABOLISM, 2013, 63 : 355 - 355
  • [8] High throughput LC-MS/MS method for simultaneous quantification of lamivudine, stavudine and nevirapine in human plasma
    Mistri, Hiren N.
    Jangid, Arvind G.
    Pudage, Ashutosh
    Gomes, Noel
    Sanyal, Mallika
    Shrivastav, Pranav
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 853 (1-2): : 320 - 332
  • [9] A simple, effective approach for rapid development of high-throughput and reliable LC-MS/MS bioanalytical assays
    Yuan, Long
    Aubry, Anne-Francoise
    Ji, Qin C.
    BIOANALYSIS, 2016, 8 (17) : 1809 - 1822
  • [10] The development and validation of a high-throughput LC-MS/MS method for the analysis of endogenous β-hydroxy-β-methylbutyrate in human plasma
    Ramachandran, Subramanian
    Ehling, Stefan
    Shreeram, Sathyavageeswaran
    Reddy, Todime M.
    BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (07)