Self-measured home blood pressure in predicting ambulatory hypertension

被引:23
|
作者
Mansoor, GA [1 ]
White, WB [1 ]
机构
[1] Univ Connecticut, Ctr Hlth, Sect Hypertens & Clin Pharmacol, Farmington, CT 06030 USA
基金
美国国家卫生研究院;
关键词
arterial hypertension; self-measurement of blood pressure; ambulatory blood pressure;
D O I
10.1016/j.amjhyper.2004.06.015
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Physicians are commonly uncertain whether a person with office blood pressure (BP) around 140/90 mm Hg actually has hypertension. This is primarily because of BP variability. One approach is to perform self-measured home BP and determine if home BP is elevated. There is a general agreement that if home BP is greater than or equal to135/85 mm Hg, then antihypertensive therapy may be commenced. However, some persons with home BP below this cut-off will have ambulatory hypertension. We therefore prospectively study the role of home BP in predicting ambulatory hypertension in persons with stage I and borderline hypertension. Methods: We studied in a cross-sectional way home and ambulatory BP in a group of 48 patients with at least two elevated office BP readings. The group was free of antihypertensive drug therapy for at least 4 weeks and performed 7 days of standardized self-BP measurements at home. We examined the relationships of the three BP methods and also defined a threshold (using receiver operating curves) for home BP that captures 80% of ambulatory hypertensives (awake BP greater than or equal to135/85 mm Hg). Results: Office systolic BP (145 +/- 13 mm Hg) was significantly higher than awake (139 +/- 12 mm Hg, P = .013) and home (132 +/- 11 mm Hg, P <.001) BP. Office diastolic BP (88 +/- 4 mm Hg) was higher than home diastolic BP (80 8 mm Hg, P <.001) but not different from awake diastolic BP (88 +/- 8 mm Hg, P =. 10). Home BP had a higher correlation (compared with office BP) with ambulatory BP. The home BP-based white coat effect correlated with ambulatory BP-based white coat effect (r = 0.83, P =.001 for systolic BP; r = 0.68, P =.001 for diastolic BP). The threshold for home BP of 80% sensitivity in capturing ambulatory hypertension was 125/76 turn Hg. Conclusions: Our preliminary data suggest that a lower self-monitored home BP threshold should be used (to exclude ambulatory hypertension) in patients with borderline office hypertension. (C) 2004 American Journal of Hypertension, Ltd.
引用
收藏
页码:1017 / 1022
页数:6
相关论文
共 50 条
  • [21] Wrist blood pressure versus clinic, self-measured home and ambulatory blood pressure. Relationships with left ventricular mass.
    Jula, A
    Karanko, H
    AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (04) : 165A - 165A
  • [22] Use of Self-Measured Blood Pressure Monitoring to Improve Hypertension Equity
    Elaine C. Khoong
    Yvonne Commodore-Mensah
    Courtney R. Lyles
    Valy Fontil
    Current Hypertension Reports, 2022, 24 : 599 - 613
  • [23] Effect of Empty-nest on Variability of Self-Measured Blood Pressure at Home in Elderly Hypertension Patients
    Zhou, T. T.
    Zhang, H.
    Liu, Z. D.
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2018, 66 : S490 - S490
  • [24] EFFECT OF EMPTY-NEST ON VARIABILITY OF SELF-MEASURED BLOOD PRESSURE AT HOME IN ELDERLY HYPERTENSION PATIENTS
    Zhou, Tingting
    Lu, Fanghong
    Liu, Zhendong
    Zhang, Hua
    JOURNAL OF HYPERTENSION, 2018, 36 : E292 - E292
  • [25] Analysis of blood pressure variability in hypertension measured by consultation, home self measurement and ambulatory blood pressure monitoring
    Abellan Huerta, J.
    Prieto-Valiente, L.
    Montoro-Garcia, S.
    Torres-Alcazar, A.
    Fernandez-Costa, A.
    Asensio-Paya, L.
    Abellan-Aleman, J.
    Soria-Arcos, F.
    EUROPEAN HEART JOURNAL, 2017, 38 : 50 - 50
  • [26] Reference values for ambulatory blood pressure and self-measured blood pressure based on prospective outcome data
    Verdecchia, P
    BLOOD PRESSURE MONITORING, 2001, 6 (06) : 323 - 327
  • [27] Comparison and Correlation between Self-measured Blood Pressure, Casual Blood Pressure Measurement and Ambulatory Blood Pressure Monitoring
    Sebba Barroso de Souza, Weimar Kunz
    Brandao Veiga Jardim, Paulo Cesar
    Porto, Ludmila Brito
    Araujo, Fabricio Alves
    Lima Sousa, Ana Luiza
    Salgado, Claudia Maria
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2011, 97 (02) : 148 - 155
  • [28] Comparison Of Automated Office Blood Pressure And Self-Measured Blood Pressure: Results From An Ongoing Self-Measured Blood Pressure Program
    Farahmand, Rosemary
    Cluett, Jennifer L.
    Barkowski, Laken
    Cohen, Marc L.
    Li, Jonathan X.
    Olowoyeye, Ruth
    Padwal, Raj
    Rakotz, Michael K.
    Russo, Elisabeth
    Sachdev, Neha
    Tighe, Katherine M.
    Tsipas, Stavros
    Walley, Hannah
    Wood, Peter S.
    Wozniak, Gregory
    Juraschek, Stephen P.
    HYPERTENSION, 2023, 80
  • [29] Relationships of Office, Ambulatory, and Self-measured Blood Pressure With Cardiac, Renal, and Atherosclerotic Biomarkers
    Narita, Keisuke
    Hoshide, Satoshi
    Kario, Kazuomi
    AMERICAN JOURNAL OF HYPERTENSION, 2024, 37 (10) : 769 - 776
  • [30] Prognosis of isolated systolic and isolated diastolic hypertension assessed by self-measured blood pressure at home: The Ohasama study
    Hozawa, A
    Ohkubo, T
    Nagai, K
    Kikuya, M
    Tsuji, I
    Ito, S
    Satoh, H
    Hisamichi, S
    Imai, Y
    JOURNAL OF HYPERTENSION, 2000, 18 : S38 - S39