Self-measured home blood pressure in predicting ambulatory hypertension

被引:23
|
作者
Mansoor, GA [1 ]
White, WB [1 ]
机构
[1] Univ Connecticut, Ctr Hlth, Sect Hypertens & Clin Pharmacol, Farmington, CT 06030 USA
基金
美国国家卫生研究院;
关键词
arterial hypertension; self-measurement of blood pressure; ambulatory blood pressure;
D O I
10.1016/j.amjhyper.2004.06.015
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Physicians are commonly uncertain whether a person with office blood pressure (BP) around 140/90 mm Hg actually has hypertension. This is primarily because of BP variability. One approach is to perform self-measured home BP and determine if home BP is elevated. There is a general agreement that if home BP is greater than or equal to135/85 mm Hg, then antihypertensive therapy may be commenced. However, some persons with home BP below this cut-off will have ambulatory hypertension. We therefore prospectively study the role of home BP in predicting ambulatory hypertension in persons with stage I and borderline hypertension. Methods: We studied in a cross-sectional way home and ambulatory BP in a group of 48 patients with at least two elevated office BP readings. The group was free of antihypertensive drug therapy for at least 4 weeks and performed 7 days of standardized self-BP measurements at home. We examined the relationships of the three BP methods and also defined a threshold (using receiver operating curves) for home BP that captures 80% of ambulatory hypertensives (awake BP greater than or equal to135/85 mm Hg). Results: Office systolic BP (145 +/- 13 mm Hg) was significantly higher than awake (139 +/- 12 mm Hg, P = .013) and home (132 +/- 11 mm Hg, P <.001) BP. Office diastolic BP (88 +/- 4 mm Hg) was higher than home diastolic BP (80 8 mm Hg, P <.001) but not different from awake diastolic BP (88 +/- 8 mm Hg, P =. 10). Home BP had a higher correlation (compared with office BP) with ambulatory BP. The home BP-based white coat effect correlated with ambulatory BP-based white coat effect (r = 0.83, P =.001 for systolic BP; r = 0.68, P =.001 for diastolic BP). The threshold for home BP of 80% sensitivity in capturing ambulatory hypertension was 125/76 turn Hg. Conclusions: Our preliminary data suggest that a lower self-monitored home BP threshold should be used (to exclude ambulatory hypertension) in patients with borderline office hypertension. (C) 2004 American Journal of Hypertension, Ltd.
引用
收藏
页码:1017 / 1022
页数:6
相关论文
共 50 条
  • [1] Self-measured versus ambulatory blood pressure in the diagnosis of hypertension
    Hond, ED
    Celis, H
    Fagard, R
    Keary, L
    Leeman, M
    O'Brien, E
    Vandenhoven, G
    Staessen, JA
    JOURNAL OF HYPERTENSION, 2003, 21 (04) : 717 - 722
  • [2] The utility of home blood pressure load in predicting average self-measured blood pressure
    Hinderliter, Alan L.
    Lin, Feng-Chang
    Yang, Yumei
    Viera, Laura A.
    Olsson, Emily
    Voora, Raven
    Viera, Anthony J.
    JOURNAL OF HYPERTENSION, 2024, 42 (09) : 1624 - 1631
  • [4] Diagnosis of Hypertension in Sleep Apnea: Self-Measured Home Versus 24 Hour Ambulatory Blood Pressure Monitoring
    Boutin, I.
    Baguet, J. P.
    Barone-Rochette, G.
    Levy, P.
    Pierre, H.
    Pepin, J. L.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [5] Practical aspect of monitoring hypertension based on self-measured blood pressure at home
    Imai, Y
    Ohkubo, T
    Kikuya, M
    Hashimoto, J
    INTERNAL MEDICINE, 2004, 43 (09) : 771 - 778
  • [6] Determinants of white-coat syndrome assessed by ambulatory blood pressure or self-measured home blood pressure
    Den Hond, E
    Celis, H
    Vandenhoven, G
    O'Brien, E
    Staessen, JA
    BLOOD PRESSURE MONITORING, 2003, 8 (01) : 37 - 40
  • [7] Blood pressure control with monitoring ambulatory blood pressure (AMBP), self-measured blood pressure at home (SMBP) and office blood pressure
    Gomez-Marcos, M. A.
    Garcia-Ortiz, L.
    Gonzalez Elena, L. J.
    Castano-Sanchez, Y.
    Rodriguez, J. I. Recio
    Parra-Sanchez, J.
    Garcia-Garcia, A.
    Cascon-Perez-Teijon, S.
    Gonzalez-Garcia, A.
    Herrero-Rodriguez, C.
    Sanchez-Salgado, B.
    Rodriguez Martin, C.
    Sanchez, C. Castano
    Jimenez, D. Munoz
    De Cabo-Laso, A.
    JOURNAL OF HYPERTENSION, 2008, 26 : S292 - S292
  • [8] Recent status of self-measured home blood pressure in the Japanese general population: a modern database on self-measured home blood pressure (MDAS)
    Kei Asayama
    Yasuharu Tabara
    Emi Oishi
    Satoko Sakata
    Takashi Hisamatsu
    Kayo Godai
    Mai Kabayama
    Yukako Tatsumi
    Jun Hata
    Masahiro Kikuya
    Kei Kamide
    Katsuyuki Miura
    Toshiharu Ninomiya
    Takayoshi Ohkubo
    Hypertension Research, 2020, 43 : 1403 - 1412
  • [9] Recent status of self-measured home blood pressure in the Japanese general population: a modern database on self-measured home blood pressure (MDAS)
    Asayama, Kei
    Tabara, Yasuharu
    Oishi, Emi
    Sakata, Satoko
    Hisamatsu, Takashi
    Godai, Kayo
    Kabayama, Mai
    Tatsumi, Yukako
    Hata, Jun
    Kikuya, Masahiro
    Kamide, Kei
    Miura, Katsuyuki
    Ninomiya, Toshiharu
    Ohkubo, Takayoshi
    HYPERTENSION RESEARCH, 2020, 43 (12) : 1403 - 1412
  • [10] Correspondence between 24-hour ambulatory, clinic home and self-measured blood pressure
    Sandova, E
    Schettini, C
    Senra, H
    Bianchi, M
    Nieto, F
    HYPERTENSION, 1999, 33 (04) : 1090 - 1090