A Randomized Trial Comparing Balloon Kyphoplasty and Vertebroplasty for Vertebral Compression Fractures due to Osteoporosis

被引:120
|
作者
Dohm, M. [1 ]
Black, C. M. [2 ,3 ]
Dacre, A. [4 ]
Tillman, J. B. [5 ]
Fueredi, G. [6 ]
机构
[1] Univ Arizona, Coll Med, Dept Orthopaed Surg, Tucson, AZ 85724 USA
[2] Utah Valley Intervent Associates, Provo, UT USA
[3] Utah Valley Reg Med Ctr, Provo, UT USA
[4] OrthoMontana, Billings, MT USA
[5] Medtron Spine, Sunnyvale, CA USA
[6] Aurora Mem Hosp Burlington, Burlington, WI USA
关键词
OSWESTRY DISABILITY INDEX; PERCUTANEOUS VERTEBROPLASTY; NONSURGICAL MANAGEMENT; IMPORTANT DIFFERENCE; DEFORMITY CORRECTION; HEIGHT RESTORATION; SPINAL FRACTURES; MEDICAL OUTCOMES; METAANALYSIS; AUGMENTATION;
D O I
10.3174/ajnr.A4127
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Several trials have compared vertebral augmentation with nonsurgical treatment for vertebral compression fractures. This trial compares the efficacy and safety of balloon kyphoplasty and vertebroplasty. MATERIALS AND METHODS: Patients with osteoporosis with 1-3 acute fractures (T5-L5) were randomized and treated with kyphoplasty (n = 191) or vertebroplasty (n = 190) and were not blinded to the treatment assignment. Twelve- and 24-month subsequent radiographic fracture incidence was the primary end point. Due to low enrollment and early withdrawals, the study was terminated with 404/1234 (32.7%) patients enrolled. RESULTS: The average age of patients was 75.6 years (77.4% female). Mean procedure duration was longer for kyphoplasty (40.0 versus 31.8 minutes, P < .001). At 12 months, 7.8% fewer patients with kyphoplasty (50/140 versus 57/131) had subsequent radiographic fracture, and there were 8.6% fewer at 24 months (54/110 versus 64/111). The results were not statistically significant (P > .21). When we used time to event for new clinical fractures, kyphoplasty approached statistical significance in longer fracture-free survival (Wilcoxon, P = .0596). Similar pain and function improvements were observed. CT demonstrated lower cement extravasation for kyphoplasty (157/214 versus 164/201 levels treated, P = .047). For kyphoplasty versus vertebroplasty, common adverse events within 30 postoperative days were procedural pain (12/191, 9/190), back pain (14/191, 28/190), and new vertebral fractures (9/191, 17/190); similar 2-year occurrence of device-related cement embolism (1/191,1/190), procedural pain (3/191, 3/190), back pain (2/191, 3/190), and new vertebral fracture (2/191, 2/190) was observed. CONCLUSIONS: Kyphoplasty and vertebroplasty had similar long-term improvement in pain and disability with similar safety profiles and few device-related complications. Procedure duration was shorter with vertebroplasty. Kyphoplasty had fewer cement leakages and a trend toward longer fracture-free survival.
引用
收藏
页码:2227 / 2236
页数:10
相关论文
共 50 条
  • [21] Percutaneous vertebroplasty and balloon kyphoplasty in the treatment of osteoporotic vertebral fractures: a prospective randomized comparison
    Griffoni, C.
    Lukassen, J. N. M.
    Babbi, L.
    Girolami, M.
    Lamartina, C.
    Cecchinato, R.
    Gasbarrini, A.
    Barbanti Brodano, G.
    EUROPEAN SPINE JOURNAL, 2020, 29 (07) : 1614 - 1620
  • [22] Balloon Kyphoplasty for the Treatment of Vertebral Compression Fractures
    Han, Kyung Ream
    Kim, Chan
    Yang, Jong Yoon
    Han, Seung Tak
    Kim, Yeui Seok
    KOREAN JOURNAL OF PAIN, 2006, 19 (01): : 56 - 62
  • [23] Percutaneous vertebroplasty and balloon kyphoplasty in the treatment of osteoporotic vertebral fractures: a prospective randomized comparison
    C. Griffoni
    J. N. M. Lukassen
    L. Babbi
    M. Girolami
    C. Lamartina
    R. Cecchinato
    A. Gasbarrini
    G. Barbanti Brodano
    European Spine Journal, 2020, 29 : 1614 - 1620
  • [24] BALLOON KYPHOPLASTY AND VERTEBROPLASTY FOR VERTEBRAL COMPRESSION FRACTURE: A SYSTEMIC REVIEW
    Hou, C-H
    OSTEOPOROSIS INTERNATIONAL, 2011, 22 : S738 - S739
  • [25] Impact of balloon kyphoplasty on quality of life and risk of recurrent vertebral fractures: A randomized trial in patients with acute vertebral compression fractures
    Boonen, S.
    Cummings, S.
    Wardlaw, D.
    Eastell, R.
    CALCIFIED TISSUE INTERNATIONAL, 2008, 82 : S40 - S41
  • [26] Efficacy and safety of balloon kyphoplasty in the treatment of osteoporotic vertebral body compression fractures: Compared with vertebroplasty
    Yi, Won Jae
    Lee, Jung Ho
    Lee, Hyuk Gee
    Ryu, Kee Young
    Kang, Ong Ee
    Kim, Sang Chul
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2007, 42 (02) : 112 - 117
  • [27] Adjacent vertebral fractures after percutaneous vertebral augmentation of osteoporotic vertebral compression fracture: a comparison of balloon kyphoplasty and vertebroplasty
    I. Movrin
    R. Vengust
    R. Komadina
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 1157 - 1166
  • [28] Balloon Kyphoplasty vs Vertebroplasty: A Systematic Review of Height Restoration in Osteoporotic Vertebral Compression Fractures
    Patel, Nimesh
    Jacobs, David
    John, Jessin
    Fayed, Mohamed
    Nerusu, Lakshmi
    Tandron, Marissa
    Dailey, William
    Ayala, Ricardo
    Sibai, Nabil
    Forrest, Patrick
    Schwalb, Jason
    Aiyer, Rohit
    JOURNAL OF PAIN RESEARCH, 2022, 15 : 1233 - 1245
  • [29] Adjacent vertebral fractures after percutaneous vertebral augmentation of osteoporotic vertebral compression fracture: a comparison of balloon kyphoplasty and vertebroplasty
    Movrin, I.
    Vengust, R.
    Komadina, R.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (09) : 1157 - 1166
  • [30] Comparison of vertebroplasty and balloon kyphoplasty for treatment of vertebral compression fractures: a meta-analysis of the literature
    Eck, Jason C.
    Nachtigall, Dean
    Humphreys, S. Craig
    Hodges, Scott D.
    SPINE JOURNAL, 2008, 8 (03): : 488 - 497