Real-time tissue perfusion assessment using fluorescence imaging topography scanning system: A preclinical investigation

被引:0
|
作者
Quang, Tri T. [1 ,2 ,3 ,4 ,5 ]
Wei, Chen F. [6 ]
Walsh, Susan A. [5 ,7 ]
Papay, Francis A. [6 ]
Liu, Yang [1 ,2 ,3 ,4 ,5 ]
机构
[1] Univ Iowa, Dept Elect & Comp Engn, 103 South Capitol St, Iowa City, IA 52242 USA
[2] Univ Iowa, Univ Iowa Technol Inst, Iowa City, IA USA
[3] Univ Iowa, Ctr Bioinformat & Computat Biol, Iowa City, IA USA
[4] Univ Iowa, Iowa Informat Initiat, Iowa City, IA USA
[5] Univ Iowa, Iowa Inst Biomed Imaging, Iowa City, IA USA
[6] Cleveland Clin, Dermatol Plast Surg Inst, Cleveland, OH 44106 USA
[7] Univ Iowa Hlth Care, Dept Radiol, Carver Coll Med, Iowa City, IA USA
关键词
fluorescence angiography; multimodal imaging; tissue perfusion; topography imaging;
D O I
10.1002/lsm.23560
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objectives: We previously developed a real-time fluorescence imaging topography scanning (RFITS) system for intraoperative multimodal imaging, image-guided surgery, and dynamic surgical navigation. The RFITS can capture intraoperative fluorescence, color reflectance, and surface topography concurrently and offers accurate registration of multimodal images. The RFITS prototype is a promising system for multimodal image guidance and intuitive 3D visualization. In the current study, we investigated the capability of the RFITS system in intraoperative fluorescence vascular angiography for real-time assessment of tissue perfusion. Study Design/Materials and Methods: We conducted ex vivo imaging of fluorescence perfusion in a soft casting life-sized human brain phantom. Indocyanine green (ICG) solutions diluted in dimethyl sulfoxide (DMSO) and human serum were injected into the brain phantom through the vessel simulating tube (2 +/- 0.2 mm inner diameter) by an adjustable flow peristaltic pump. To demonstrate the translational potential of the system, an ICG/DMSO solution was perfused into blood vessels of freshly harvested porcine ears (n = 9, inner diameter from 0.56 to 1.27 mm). We subsequently performed in vivo imaging of fluorescence-perfused vascular structures in rodent models (n = 10). 5 mg/ml ICG solutions prepared in sterile water were injected via the lateral tail vein. All targets were imaged by the RFITS prototype at a working distance of 350-400 mm. Results: 3D visualization of 10 mu g/ml ICG-labeled continuous moving serum in the brain phantom was obtained at an average signal-to-background ratio (SBR) of 1.74 +/- 0.03. The system was able to detect intravenously diffused fluorescence in porcine tissues with an average SBR of 2.23 +/- 0.22. The RFITS prototype provided real-time monitoring of tissue perfusion in rats after intravenous (IV) administration of ICG. The maximum fluorescence intensity (average SBR = 1.94 +/- 0.16, p < 0.001) was observed at T-peak of similar to 30 seconds after the ICG signal was first detected (average SBR = 1.19 +/- 0.13, p < 0.01). Conclusions: We have conducted preclinical studies to demonstrate the feasibility of applying the RFITS system in real-time fluorescence angiography and tissue perfusion assessment. Our system provides fluorescence/color composite images for intuitive visualization of tissue perfusion with 3D perception. The findings pave the way for future clinical translation.
引用
收藏
页码:994 / 1001
页数:8
相关论文
共 50 条
  • [31] Hybrid system for in vivo real-time planar fluorescence and volumetric optoacoustic imaging
    Chen, Zhenyue
    Dean-Ben, Xose Luis
    Gottschalk, Sven
    Razansky, Daniel
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2018, 2018, 10494
  • [32] Assessment of tissue perfusion and vascular function in mice by scanning laser Doppler perfusion imaging
    Leo, Francesca
    Krenz, Thomas
    Wolff, Georg
    Weidenbach, Mathias
    Heiss, Christian
    Kelm, Malte
    Isakson, Brant
    Cortese-Krott, Miriam M.
    BIOCHEMICAL PHARMACOLOGY, 2020, 176
  • [33] Real-time assessment of tissue perfusion following bubble destruction at low emission power -: First experimental results using power pulse inversion imaging
    Tiemann, K
    Becher, H
    Lohmeier, S
    Köster, J
    Kuntz, S
    Lüderitz, B
    Averkiou, M
    Skyba, D
    Bruce, M
    Powers, JE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 426A - 426A
  • [34] Real-time Imaging of tissue microstructures using intrinsic optical signatures
    Lin, Bevin
    Lieber, Chad A.
    Fitzgerald, Jason T.
    Michalopoulou, Andromachi P.
    Raman, Rajesh N.
    Pivetti, Christopher D.
    Troppmann, Christoph
    Matthews, Dennis L.
    Demos, Stavros G.
    OPTICAL BIOPSY VI, 2006, 6091
  • [35] REAL-TIME ULTRASOUND PERFUSION IMAGING IN ACUTE STROKE: ASSESSMENT OF CEREBRAL PERFUSION DEFICITS RELATED TO ARTERIAL RECANALIZATION
    Bolognese, Manuel
    Artemis, Dimitrios
    Alonso, Angelika
    Hennerici, Michael G.
    Meairs, Stephan
    Kern, Rolf
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (05): : 745 - 752
  • [36] Magnetic Particle Imaging for Real-Time Perfusion Imaging in Acute Stroke
    Ludewig, Peter
    Gdaniec, Nadine
    Sedlacik, Jan
    Forkert, Nils D.
    Szwargulski, Patryk
    Graeser, Matthias
    Adam, Gerhard
    Kaul, Michael G.
    Krishnan, Kaman M.
    Ferguson, R. Matthew
    Khandhar, Amit P.
    Walczak, Piotr
    Fiehler, Jens
    Thomalla, Goetz
    Gerloff, Christian
    Knopp, Tobias
    Magnus, Tim
    ACS NANO, 2017, 11 (10) : 10480 - 10488
  • [37] A REAL-TIME CONFOCAL LASER SCANNING MICROSCOPE FOR FLUORESCENCE AND REFLECTION
    HOUPT, PM
    DRAAIJER, A
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1990, (98): : 639 - 642
  • [38] Real-Time Photoplethysmography Imaging System
    Rubins, U.
    Upmalis, V.
    Rubenis, O.
    Jakovels, D.
    Spigulis, J.
    15TH NORDIC-BALTIC CONFERENCE ON BIOMEDICAL ENGINEERING AND MEDICAL PHYSICS (NBC 2011), 2011, 34 : 183 - 186
  • [39] Intraoperative Real-Time Assessment of Liver Function with Near-Infrared Fluorescence Imaging
    Narasaki, Hajime
    Noji, Takehiro
    Wada, Hideyuki
    Ebihara, Yuma
    Tsuchikawa, Takahiro
    Okamura, Keisuke
    Tanaka, Eiichi
    Shichinohe, Toshiaki
    Hirano, Satoshi
    EUROPEAN SURGICAL RESEARCH, 2017, 58 (5-6) : 235 - 245
  • [40] Real-Time Imaging System for the OpenPET
    Tashima, Hideaki
    Yoshida, Eiji
    Kinouchi, Shoko
    Nishikido, Fumihiko
    Inadama, Naoko
    Murayama, Hideo
    Suga, Mikio
    Haneishi, Hideaki
    Yamaya, Taiga
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (01) : 40 - 46