Real-time tissue perfusion assessment using fluorescence imaging topography scanning system: A preclinical investigation

被引:0
|
作者
Quang, Tri T. [1 ,2 ,3 ,4 ,5 ]
Wei, Chen F. [6 ]
Walsh, Susan A. [5 ,7 ]
Papay, Francis A. [6 ]
Liu, Yang [1 ,2 ,3 ,4 ,5 ]
机构
[1] Univ Iowa, Dept Elect & Comp Engn, 103 South Capitol St, Iowa City, IA 52242 USA
[2] Univ Iowa, Univ Iowa Technol Inst, Iowa City, IA USA
[3] Univ Iowa, Ctr Bioinformat & Computat Biol, Iowa City, IA USA
[4] Univ Iowa, Iowa Informat Initiat, Iowa City, IA USA
[5] Univ Iowa, Iowa Inst Biomed Imaging, Iowa City, IA USA
[6] Cleveland Clin, Dermatol Plast Surg Inst, Cleveland, OH 44106 USA
[7] Univ Iowa Hlth Care, Dept Radiol, Carver Coll Med, Iowa City, IA USA
关键词
fluorescence angiography; multimodal imaging; tissue perfusion; topography imaging;
D O I
10.1002/lsm.23560
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objectives: We previously developed a real-time fluorescence imaging topography scanning (RFITS) system for intraoperative multimodal imaging, image-guided surgery, and dynamic surgical navigation. The RFITS can capture intraoperative fluorescence, color reflectance, and surface topography concurrently and offers accurate registration of multimodal images. The RFITS prototype is a promising system for multimodal image guidance and intuitive 3D visualization. In the current study, we investigated the capability of the RFITS system in intraoperative fluorescence vascular angiography for real-time assessment of tissue perfusion. Study Design/Materials and Methods: We conducted ex vivo imaging of fluorescence perfusion in a soft casting life-sized human brain phantom. Indocyanine green (ICG) solutions diluted in dimethyl sulfoxide (DMSO) and human serum were injected into the brain phantom through the vessel simulating tube (2 +/- 0.2 mm inner diameter) by an adjustable flow peristaltic pump. To demonstrate the translational potential of the system, an ICG/DMSO solution was perfused into blood vessels of freshly harvested porcine ears (n = 9, inner diameter from 0.56 to 1.27 mm). We subsequently performed in vivo imaging of fluorescence-perfused vascular structures in rodent models (n = 10). 5 mg/ml ICG solutions prepared in sterile water were injected via the lateral tail vein. All targets were imaged by the RFITS prototype at a working distance of 350-400 mm. Results: 3D visualization of 10 mu g/ml ICG-labeled continuous moving serum in the brain phantom was obtained at an average signal-to-background ratio (SBR) of 1.74 +/- 0.03. The system was able to detect intravenously diffused fluorescence in porcine tissues with an average SBR of 2.23 +/- 0.22. The RFITS prototype provided real-time monitoring of tissue perfusion in rats after intravenous (IV) administration of ICG. The maximum fluorescence intensity (average SBR = 1.94 +/- 0.16, p < 0.001) was observed at T-peak of similar to 30 seconds after the ICG signal was first detected (average SBR = 1.19 +/- 0.13, p < 0.01). Conclusions: We have conducted preclinical studies to demonstrate the feasibility of applying the RFITS system in real-time fluorescence angiography and tissue perfusion assessment. Our system provides fluorescence/color composite images for intuitive visualization of tissue perfusion with 3D perception. The findings pave the way for future clinical translation.
引用
收藏
页码:994 / 1001
页数:8
相关论文
共 50 条
  • [1] REAL-TIME TISSUE PERFUSION ASSESSMENT USING FLUORESCENCE IMAGING TOPOGRAPHY SCANNING SYSTEM
    Quang, Tri T.
    Walsh, Susan
    Liu, Yang
    LASERS IN SURGERY AND MEDICINE, 2020, 52 : S16 - S16
  • [2] Real-Time Longitudinal Evaluation of Tumor Blood Vessels Using a Compact Preclinical Fluorescence Imaging System
    Jeong, Hoibin
    Kim, Song-Rae
    Kang, Yujung
    Kim, Huisu
    Kim, Seo-Young
    Cho, Su-Hyeon
    Kim, Kil-Nam
    BIOSENSORS-BASEL, 2021, 11 (12):
  • [3] Objective, real-time, intraoperative assessment of renal perfusion using infrared imaging
    Gorbach, A
    Simonton, D
    Hale, DA
    Swanson, SJ
    Kirk, AD
    AMERICAN JOURNAL OF TRANSPLANTATION, 2003, 3 (08) : 988 - 993
  • [4] Real-time fluorescence imaging system for cancer diagnostics
    Sokolov, VV
    Chissov, VI
    Fabelinsky, VI
    Smirnov, VV
    Zharkova, NN
    BIOMEDICAL OPTOELECTRONICS IN CLINICAL CHEMISTRY AND BIOTECHNOLOGY, PROCEEDINGS OF, 1996, 2629 : 271 - 274
  • [5] Fluorescence Imaging Topography Scanning System for intraoperative multimodal imaging
    Quang, Tri T.
    Kim, Hye-Yeong
    Bao, Forrest Sheng
    Papay, Francis A.
    Edwards, W. Barry
    Liu, Yang
    PLOS ONE, 2017, 12 (04):
  • [6] REAL-TIME CONFOCAL SCANNING IMAGING OF THE EYE - INSTRUMENT PERFORMANCE OF REFLECTANCE AND FLUORESCENCE IMAGING
    MASTERS, BR
    KINO, GS
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1990, (98): : 625 - 628
  • [7] Real-Time Comprehensive Human Islet Assessment In Vitro Using Fluorescence Imaging and Microfluidic Perifusion System.
    Wang, Yong
    Mohammed, Javeed
    Harvat, Tricia
    Qi, Merigeng
    Wang, Shusen
    Eddington, David T.
    Oberholzer, Jose
    AMERICAN JOURNAL OF TRANSPLANTATION, 2009, 9 : 673 - 673
  • [8] Investigation of an acoustical holography system for real-time imaging
    Fecht, BA
    Andre, MP
    Garlick, GF
    Shelby, RL
    Shelby, JO
    Lehman, CD
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 106 - 112
  • [9] Mouse tissue imaging using real-time Lissajous confocal endomicroscopic system
    Hwang, Kyungmin
    Seo, Yeong-Hyeon
    Kim, Daniel Y.
    Kim, Jae-Beom
    Ahn, Jinhyo
    Lee, Soyoung
    Jon, Sangyong
    Kim, Pilhan
    Jeong, Ki-Hun
    2017 INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND NANOPHOTONICS (OMN), 2017, : 79 - 80
  • [10] Quantitative assessment of myocardial perfusion using real-time three-dimensional echocardiographic Imaging
    Toledo, E
    Lang, RM
    Collins, KA
    Williams, U
    Lammertin, G
    Weinert, L
    Mor-Avi, V
    Computers in Cardiology 2004, Vol 31, 2004, 31 : 225 - 228