Study of unfolded gamma spectra by using EJ309 liquid scintillator detector

被引:4
|
作者
Zhang, Shuangjiao [1 ]
Liu, Changqi [1 ]
Yang, Xu [1 ]
Huang, Chang [1 ]
Xie, Qin [1 ]
Hu, Zhijie [1 ]
Hu, Zhiming [1 ]
Han, Chao [1 ]
Bai, Xiaohou [1 ]
Huo, Dongying [1 ]
Wu, Kang [1 ]
Wang, Junrun [1 ,2 ]
Zhang, Yu [1 ,2 ]
Wei, Zheng [1 ,2 ]
Yao, Zeen [1 ,2 ]
机构
[1] Lanzhou Univ, Sch Nucl Sci & Technol, Lanzhou 730000, Peoples R China
[2] Lanzhou Univ, Engn Res Ctr Neutron Applicat Technol, Minist Educ, Lanzhou 730000, Peoples R China
基金
中国国家自然科学基金;
关键词
Liquid scintillator detector; Unfolding calculation; Gamma spectrum; Monte Carlo simulation; LIGHT OUTPUT RESPONSE; DETECTION EFFICIENCY; ENERGY RESOLUTION; NEUTRON; RAY; DECONVOLUTION; CALIBRATION; SIMULATION; BC501A;
D O I
10.1016/j.nima.2021.165407
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The EJ309 liquid scintillator detector and the developed gamma spectrum unfolding procedure are used to study the complex gamma spectra. The EJ309 liquid scintillator detector is calibrated by using measured response functions of the standard gamma sources Ba-133, Cs-137, and Co-60, which are verified by Monte Carlo simulations for detector calibration accuracy. A gamma spectra unfolding procedure is developed based on the One-fold Gold algorithm, which is used for unfolding simulated complex gamma spectra, experimentally measured response function of Ba-133 and Cs-137, and composed complex gamma spectra using measured response function of Ba-133 and Cs-137 with different relative intensities (RI). The data of unfolded gamma-ray spectra are compared with the standard data. The results show that the EJ309 liquid scintillator detector and the developed gamma spectra unfolding procedure can quantitative and qualitative analysis of complex gamma spectra with reasonable accuracy.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Neutron-gamma pulse shape discrimination for EJ301 liquid scintillator based on machine learning
    Xu, Jiahao
    Cheng, Wei
    Jia, Wenbao
    Chen, Qingbo
    Zhang, Ronghua
    Zhang, Yan
    Cheng, Can
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (02) : 905 - 916
  • [32] CHARACTERISTICS OF A GAMMA-RAY DETECTOR USING A BISMUTH-GERMANATE SCINTILLATOR
    OKAJIMA, K
    TAKAMI, K
    UEDA, K
    KAWAGUCHI, F
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1982, 53 (08): : 1285 - 1286
  • [33] Optical study of a large-scale liquid-scintillator detector
    Masetti, F
    Elisei, F
    Mazzucato, U
    JOURNAL OF LUMINESCENCE, 1996, 68 (01) : 15 - 25
  • [34] Proton decay in the large liquid scintillator detector LENA:: study of the background
    Undagoitia, T. Marrodan
    von Feilitzsch, F.
    Goeger-Neff, M.
    Grieb, C.
    Hochmuth, K. A.
    Oberauer, L.
    Potzel, W.
    Wurm, M.
    TAUP 2005: PROCEEDINGS OF THE NINTH INTERNATIONAL CONFERENCE ON TOPICS IN ASTROPARTICLE AND UNDERGROUND PHYSICS, 2006, 39 : 269 - +
  • [35] Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector
    Abusleme, A.
    Adam, T.
    Ahmad, S.
    Aiello, S.
    Akram, M.
    Ali, N.
    An, F. P.
    An, G. P.
    An, Q.
    Andronico, G.
    Anfimov, N.
    Antonelli, V
    Antoshkina, T.
    Asavapibhop, B.
    de Andre, J. P. A. M.
    Babic, A.
    Balantekin, A. B.
    Baldini, W.
    Baldoncini, M.
    Band, H. R.
    Barresi, A.
    Baussan, E.
    Bellato, M.
    Bernieri, E.
    Biare, D.
    Birkenfeld, T.
    Bishai, M.
    Blin, S.
    Blum, D.
    Blyth, S.
    Bordereau, C.
    Brigatti, A.
    Brugnera, R.
    Budano, A.
    Burgbacher, P.
    Buscemi, M.
    Bussino, S.
    Busto, J.
    Butorov, I
    Cabrera, A.
    Cai, H.
    Cai, X.
    Cai, Y. K.
    Cai, Z. Y.
    Cammi, A.
    Campeny, A.
    Cao, C. Y.
    Cao, G. F.
    Cao, J.
    Caruso, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 988 (988):
  • [36] Study of Multi-Pixel Scintillator Detector Configurations for Measuring Polarized Gamma Radiation
    Kozuljevic, Ana Marija
    Bosnar, Damir
    Kuncic, Zdenka
    Makek, Mihael
    Parashari, Siddharth
    Zugec, Petar
    CONDENSED MATTER, 2021, 6 (04):
  • [37] DETECTOR PERTURBATIONS TO NEUTRON AND GAMMA-RAY SPECTRA MEASUREMENTS IN LIQUID AIR
    GRITZNER, ML
    SCOTT, WH
    ALBERT, TE
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1978, 28 (JUN): : 624 - 626
  • [38] Radiation damage in scintillator detector chemical compounds: A new approach using PPO-Toluene liquid scintillator as a model
    Mesquita, CH
    Neto, JMF
    Duarte, CL
    Rela, PR
    Hamada, MM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) : 1669 - 1673
  • [39] Qualification and performance of a neutron detector system with enhanced gamma discrimination, based on Silicon Photomultiplier arrays coupled to an EJ-299-34 scintillator
    Santoro, Romualdo
    Caccia, Massimo
    Malinverno, Luca
    Martemiyanov, Alexander
    Ellis, Mark
    Allwork, Chris
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [40] Monte Carlo Simulation Study for Gamma Energy Deposition in Scintillator Coupled Silicon Photomultiplier Detector
    Srivastava, Saurabh
    Mitra, Pratip
    Kumar, Amit
    Kumar, A. Vinod
    Topkar, Anita
    DAE SOLID STATE PHYSICS SYMPOSIUM 2019, 2020, 2265