Analysis and correction of field fluctuations in fMRI data using field monitoring

被引:29
|
作者
Bollmann, Saskia [1 ,2 ,7 ]
Kasper, Lars [1 ,2 ,3 ,4 ]
Vannesjo, S. Johanna [1 ,2 ,8 ]
Diaconescu, Andreea O. [3 ,4 ]
Dietrich, Benjamin E. [1 ,2 ]
Gross, Simon [1 ,2 ]
Stephan, Klaas E. [3 ,4 ,5 ,6 ]
Pruessmann, Klaas P. [1 ,2 ]
机构
[1] Swiss Fed Inst Technol, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] Univ Zurich, CH-8092 Zurich, Switzerland
[3] Univ Zurich, Inst Biomed Engn, TNU, CH-8032 Zurich, Switzerland
[4] Swiss Fed Inst Technol, CH-8032 Zurich, Switzerland
[5] UCL, Wellcome Trust Ctr Neuroimaging, London WC1N 3BG, England
[6] Max Planck Inst Metab Res, D-50931 Cologne, Germany
[7] Univ Queensland, Ctr Adv Imaging, Brisbane, Qld 4072, Australia
[8] Univ Oxford, Nuffield Dept Clin Neurosci, FMRIB Ctr, Oxford, England
关键词
fMRI; Echo-planar imaging; Field fluctuations; Physiological noise; SFNR; Magnetic field monitoring; INDEPENDENT COMPONENT ANALYSIS; INDUCED B-0 FLUCTUATIONS; STATIC MAGNETIC-FIELD; ECHO-PLANAR; HUMAN BRAIN; PHYSIOLOGICAL NOISE; RETROSPECTIVE CORRECTION; IMAGE-RECONSTRUCTION; SUBJECT MOTION; FUNCTIONAL MRI;
D O I
10.1016/j.neuroimage.2017.01.014
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This work investigates the role of magnetic field fluctuations as a confound in fMRI. In standard fMRI experiments with single-shot EPI acquisition at 3 Tesla the uniform and gradient components of the magnetic field were recorded with NMR field sensors. By principal component analysis it is found that differences of field evolution between the EPI readouts are explainable by few components relating to slow and within-shot field dynamics of hardware and physiological origin. The impact of fluctuating field components is studied by selective data correction and assessment of its influence on image fluctuation and SFNR. Physiological field fluctuations, attributed to breathing, were found to be small relative to those of hardware origin. The dominant confounds were hardware-related and attributable to magnet drift and thermal changes. In raw image time series, field fluctuation caused significant SFNR loss, reflected by a 67% gain upon correction. Large part of this correction can be accomplished by traditional image realignment, which addresses slow and spatially uniform field changes. With realignment, explicit field correction increased the SFNR on the order of 6%. In conclusion, field fluctuations are a relevant confound in fMRI and can be addressed effectively by retrospective data correction. Based on the physics involved it is anticipated that the advantage of full field correction increases with field strength, with non-Cartesian readouts, and upon phase-sensitive BOLD analysis.
引用
收藏
页码:92 / 105
页数:14
相关论文
共 50 条
  • [1] Retrospective Correction of Physiological Field Fluctuations in High-Field Brain MRI Using Concurrent Field Monitoring
    Vannesjo, S. Johanna
    Wilm, Bertram J.
    Duerst, Yolanda
    Gross, Simon
    Brunner, David O.
    Dietrich, Benjamin E.
    Schmid, Thomas
    Barmet, Christoph
    Pruessmann, Klaas P.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (05) : 1833 - 1843
  • [2] Monitoring, analysis, and correction of magnetic field fluctuations in echo planar imaging time series
    Kasper, Lars
    Bollmann, Saskia
    Vannesjo, S. Johanna
    Gross, Simon
    Haeberlin, Maximilian
    Dietrich, Benjamin E.
    Pruessmann, Klaas P.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (02) : 396 - 409
  • [3] An analysis method based on correction of estimated value of β for fMRI at low field
    Yang, Ping
    He, Yan-Fa
    Wang, Jin-Xing
    Yu, Bing
    Dongbei Daxue Xuebao/Journal of Northeastern University, 2010, 31 (02): : 165 - 167
  • [4] Mapping rabbit whisker barrels using discriminant analysis of high field fMRI data
    Song, Xiaomu
    Li, Limin
    Aksenov, Daniil
    Miller, Michael J.
    Wyrwicz, Alice M.
    NEUROIMAGE, 2010, 51 (02) : 775 - 782
  • [5] Dynamic field mapping and distortion correction for fMRI
    Xu, Ning
    Fitzpatrick, J. Michael
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [6] Monitoring of rice field using SAR data and optical data
    Ogawa, S
    Inoue, Y
    Mino, N
    Tomita, A
    SECOND INTERNATIONAL WORKSHOP ON RETRIEVAL OF BIO- & GEO-PHYSICAL PARAMETERS FROM SAR DATA FOR LAND APPLICATIONS, 1998, 441 : 155 - 159
  • [7] An Agricultural Monitoring System: Field Server Data Collection and Analysis on Paddy Field
    Soontranon, Narut
    Tangpattanakul, Panwadee
    Srestasathiern, Panu
    Rakwatin, Preesan
    2014 14TH INTERNATIONAL SYMPOSIUM ON COMMUNICATIONS AND INFORMATION TECHNOLOGIES (ISCIT), 2014, : 597 - 601
  • [8] Correction of parallel transmission using concurrent RF and gradient field monitoring
    Cavusoglu, Mustafa
    Dietrich, Benjamin Emanuel
    Brunner, David Otto
    Weiger, Markus
    Pruessmann, Klaas Paul
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (05) : 473 - 488
  • [9] Correction of parallel transmission using concurrent RF and gradient field monitoring
    Mustafa Çavuşoğlu
    Benjamin Emanuel Dietrich
    David Otto Brunner
    Markus Weiger
    Klaas Paul Pruessmann
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2017, 30 : 473 - 488
  • [10] A correction algorithm for improved magnetic field monitoring with distal field probes
    Dubovan, Paul I. I.
    Gilbert, Kyle M. M.
    Baron, Corey A. A.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (06) : 2242 - 2260