The calibration of a turbine meter as a secondary flow-rate standard by a one-point relative method using laser Doppler velocimetry

被引:1
|
作者
March, JF [1 ]
机构
[1] Phys Tech Bundesanstalt, Fachlab Messung Therm Energie, D-10587 Berlin, Germany
关键词
D O I
10.1088/0957-0233/9/1/017
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Heat district suppliers demand carefully constructed and calibrated flow sensors of heat meters at temperatures above 100 degrees C for long-term use. The calibration at these temperatures cannot be performed by the common gravimetric standard method due to technical difficulties. A novel one-point relative method using a laser Doppler velocimeter (LDV) was therefore developed which is based on the gravimetric method below 100 degrees C and on the Reynolds law. This method allows a turbine meter to be calibrated as a secondary flow-rate standard with a relative uncertainty less than or equal to 0.2% for temperatures up to 180 degrees C with regard to the flow rate.
引用
收藏
页码:129 / 132
页数:4
相关论文
共 24 条
  • [1] Calibration of the fiberoptical one-point flow meter characterized by spatial filtering
    Petrak, D
    Mahr, P
    TECHNISCHES MESSEN, 2000, 67 (11): : 474 - 478
  • [2] Cryogenic flow rate measurement with a laser Doppler velocimetry standard
    Maury, R.
    Strzelecki, A.
    Auclercq, C.
    Lehot, Y.
    Loubat, S.
    Chevalier, J.
    Ben Rayana, F.
    Olsen, A. A. F.
    Chupin, G.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (03)
  • [3] Single-point relative method using laser-Doppler velocimetry for calibration of flow sensors at temperatures above 100 degrees centigrade
    March, JF
    PTB-MITTEILUNGEN, 1996, 106 (06): : 403 - 407
  • [4] Pelton turbine jet flow investigations using laser Doppler velocimetry
    Khan, Firoz
    Kumar, Arun
    PHYSICS OF FLUIDS, 2023, 35 (12)
  • [5] SIMPLE METHOD TO PREDICT POWER LEVEL AND CORE FLOW-RATE OF BOILING WATER-REACTORS BY USING ONE-POINT CORE MODEL
    UMEGAKI, K
    KIGUCHI, T
    MOTODA, H
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1982, 19 (07) : 513 - 520
  • [6] One-point and multi-line calibration method in laser-induced breakdown spectroscopy
    Hao, Z. Q.
    Liu, L.
    Zhou, R.
    Ma, Y. W.
    Li, X. Y.
    Guo, L. B.
    Lu, Y. F.
    Zeng, X. Y.
    OPTICS EXPRESS, 2018, 26 (18): : 22926 - 22933
  • [7] Self-absorption correction method for one-point calibration laser-induced breakdown spectroscopy
    Hu, Zhenlin
    Nie, Junfei
    Ouyang, Zhiyong
    Zhang, Deng
    Liu, Yuanchao
    Chu, Yanwu
    Guo, Lianbo
    OPTICS LETTERS, 2023, 48 (01) : 1 - 4
  • [8] A primary standard for the volume flow rate of natural gas under high pressure based on laser Doppler velocimetry
    Mickan, B.
    Strunck, V.
    METROLOGIA, 2014, 51 (05) : 459 - 475
  • [9] Quantitative analysis of titanium alloys using one-point calibration laser-induced breakdown spectroscopy
    Hai, Ran
    Tong, Weina
    Wu, Ding
    He, Zhonglin
    Sattar, Harse
    Li, Cong
    Ding, Hongbin
    APPLIED PHYSICS B-LASERS AND OPTICS, 2021, 127 (03):
  • [10] Quantitative analysis of titanium alloys using one-point calibration laser-induced breakdown spectroscopy
    Ran Hai
    Weina Tong
    Ding Wu
    Zhonglin He
    Harse Sattar
    Cong Li
    Hongbin Ding
    Applied Physics B, 2021, 127