Comparison of fluid dynamics changes due to physical activity in 3D printed patient specific coronary phantoms with the Windkessel equivalent model of coronary flow

被引:1
|
作者
Sommer, Kelsey N. [1 ,2 ,3 ]
Bhurwani, Mohammad Mahdi Shiraz [1 ,2 ]
Iyer, Vijay [4 ]
Ionita, Ciprian N. [1 ,2 ,3 ]
机构
[1] Univ Buffalo, Dept Biomed Engn, Buffalo, NY 14260 USA
[2] Univ Buffalo, Canon Stroke & Vasc Res Ctr, Buffalo, NY 14260 USA
[3] QAS AI Inc, Buffalo, NY 14203 USA
[4] Univ Buffalo, Cardiol, Jacobs Sch Med, Buffalo, NY USA
关键词
3D Printing; Coronary Artery Disease; Coronary CTA; Windkessel model; RESISTANCE; PRESSURE;
D O I
10.1186/s41205-022-00138-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background 3D printing (3DP) used to replicate the geometry of normal and abnormal vascular pathologies has been demonstrated in many publications; however, reproduction of hemodynamic changes due to physical activities, such as rest versus moderate exercise, need to be investigated. We developed a new design for patient specific coronary phantoms, which allow adjustable physiological variables such as coronary distal resistance and coronary compliance in patients with coronary artery disease. The new design was tested in precise benchtop experiments and compared with a theoretical Windkessel electrical circuit equivalent, that models coronary flow and pressure using arterial resistance and compliance. Methods Five phantoms from patients who underwent clinically indicated elective invasive coronary angiography were built from CCTA scans using multi-material 3D printing. Each phantom was used in a controlled flow system where patient specific flow conditions were simulated by a programmable cardiac pump. To simulate the arteriole and capillary beds flow resistance and the compliance for various physical activities, we designed a three-chamber outlet system which controls the outflow dynamics of each coronary tree. Benchtop pressure measurements were recorded using sensors embedded in each of the main coronary arteries. Using the Windkessel model, patient specific flow equivalent electrical circuit models were designed for each coronary tree branch, and flow in each artery was determined for known inflow conditions. Local flow resistances were calculated through Poiseuille's Law derived from the radii and lengths of the coronary arteries using CT angiography based multi-planar reconstructions. The coronary stenosis flow rates from the benchtop and the electrical models were compared to the localized flow rates calculated from invasive pressure measurements recorded in the angio-suites. Results The average Pearson correlations of the localized flow rates at the location of the stenosis between each of the models (Benchtop/Electrical, Benchtop/Angio, Electrical/Angio) are 0.970, 0.981, and 0.958 respectively. Conclusions 3D printed coronary phantoms can be used to replicate the human arterial anatomy as well as blood flow conditions. It displays high levels of correlation when compared to hemodynamics calculated in electrically-equivalent coronary Windkessel models as well as invasive angio-suite pressure measurements.
引用
收藏
页数:10
相关论文
共 30 条
  • [21] A simple framework to generate 3D patient-specific model of coronary artery bifurcation from single-plane angiographic images
    Auricchio, Ferdinando
    Conti, Michele
    Ferrazzano, Carolina
    Sgueglia, Gregory A.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2014, 44 : 97 - 109
  • [22] Influence of Hemodynamic Factors on Rupture of Intracranial Aneurysms: Patient-Specific 3D Mirror Aneurysms Model Computational Fluid Dynamics Simulation
    Lu, G.
    Huang, L.
    Zhang, X. L.
    Wang, S. Z.
    Hong, Y.
    Hu, Z.
    Geng, D. Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (07) : 1255 - 1261
  • [23] 3D numerical model of blood flow in the coronary artery bypass graft during no pulse and pulse situations: Effects of an anastomotic angle and characteristics of fluid
    Koksungnoen, Satiraporn
    Rattanadecho, Phadungsak
    Wongchadakul, Patcharaporn
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2018, 32 (09) : 4545 - 4552
  • [24] PATIENT-SPECIFIC VALVE DYNAMICS USING 3D FLUID-STRUCTURE INTERACTION MODELING: COMPARISON BETWEEN BICUSPID AND TRISCUSPID AORTIC VALVES
    Govindarajan, V.
    Mousel, J.
    Vigmostad, S. C.
    Udaykumar, H. S.
    Levack, M. M.
    Gorman, J. H., III
    Jackson, B. M.
    Gorman, R. C.
    Chandran, K. B.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [25] 3D numerical model of blood flow in the coronary artery bypass graft during no pulse and pulse situations: Effects of an anastomotic angle and characteristics of fluid
    Satiraporn Koksungnoen
    Phadungsak Rattanadecho
    Patcharaporn Wongchadakul
    Journal of Mechanical Science and Technology, 2018, 32 : 4545 - 4552
  • [26] Using 2D in vivo ivus-based models for human coronary plaque progression analysis and comparison with 3d fluid-structure interaction models: A multi-patient study
    Wang, Hongjian
    Zheng, Jie
    Wang, Liang
    Maehara, Akiko
    Yang, Chun
    Muccigrosso, David
    Bach, Richard
    Zhu, Jian
    Mintz, Gary S.
    Tang, Dalin
    MCB Molecular and Cellular Biomechanics, 2015, 12 (02): : 107 - 122
  • [27] Using 2D In Vivo IVUS-Based Models for Human Coronary Plaque Progression Analysis and Comparison with 3D Fluid-Structure Interaction Models: A Multi-Patient Study
    Wang, Hongjian
    Zheng, Jie
    Wang, Liang
    Maehara, Akiko
    Yang, Chun
    Muccigrosso, David
    Bach, Richard
    Zhu, Jian
    Mintz, Gary S.
    Tang, Dalin
    MOLECULAR & CELLULAR BIOMECHANICS, 2015, 12 (02) : 107 - 122
  • [28] 3D MR flow analysis in realistic rapid-prototyping model systems of the thoracic aorta:: Comparison with in vivo data and computational fluid dynamics in identical vessel geometries
    Canstein, C.
    Cachot, P.
    Faust, A.
    Stalder, A. F.
    Bock, J.
    Frydrychowicz, A.
    Kueffer, J.
    Hennig, J.
    Markl, M.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) : 535 - 546
  • [29] 4D phase contrast MRI in intracranial aneurysms: a comparison with patient-specific computational fluid dynamics with temporal and spatial velocity boundary conditions as measured with 3D phase contrast MRI
    Pim van Ooij
    Joppe Schneiders
    Henk Marquering
    Charles B Majoie
    Ed vanBavel
    Aart Nederveen
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [30] Coronary Artery Disease-Related Death May Be Associated With Higher Critical Plaque Wall Stress: A Multi-Patient 3D Fluid-Structure Interaction Study Comparing Plaque Wall Stress, Flow Shear Stress, and Plaque Burden as Risk Indicators
    Huang, Xueying
    Yang, Chun
    Zheng, Jie
    Bach, Richard
    Muccigrosso, David
    Woodard, Pamela K.
    Tang, Dalin
    CIRCULATION, 2013, 128 (22)