Gadolinium contrast agents - are they really safe?

被引:30
|
作者
Malikova, Hana [1 ,2 ,3 ]
Holesta, Michal [1 ,2 ]
机构
[1] Charles Univ Prague, Fac Hosp Kralovske Vinohrady, Dept Radiol, Srobarova 50, Prague 10000, Czech Republic
[2] Charles Univ Prague, Fac Med 3, Srobarova 50, Prague, Czech Republic
[3] Charles Univ Prague, Med Fac 2, Inst Anat, Prague, Czech Republic
来源
关键词
Dentate nucleus; Deposition disease; Globus pallidus; Toxicity; NEPHROGENIC SYSTEMIC FIBROSIS; HIGH-SIGNAL INTENSITY; UNENHANCED T1-WEIGHTED IMAGES; PLASMA-MASS SPECTROSCOPY; NORMAL RENAL-FUNCTION; HUMAN BONE TISSUE; DENTATE NUCLEUS; GLOBUS-PALLIDUS; GADODIAMIDE; RETENTION;
D O I
10.5301/jva.5000713
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Gadolinium-based contrast agents (GBCA) are used worldwide for enhanced MRI examinations, including heart and vessels. Gadolinium is a highly toxic heavy metal. If used in GBCA it must be tightly bound to ligands. The configuration of ligands influences the stability of the GBCA and two types of chelates have been used. Macrocyclic chelates offer better protection and binding of gadolinium ion than linear chelates with a flexible open chain - gadolinium could be more easily released from the latter ones. GBCAs are excreted from the body mostly by the kidneys, which is of importance in chronic kidney disease. Two states are related to gadolinium: nephrogenic systemic fibrosis (NSF) and gadolinium body storage. NSF is a severe and debilitating disease, directly connected to gadolinium toxicity, proven after the use of linear chelates. Due to strict recommendations of radiology societies, NSF was practically eradicated. Gadolinium deposition was observed especially in bones and in some brain areas: in dentate nucleus and in globus pallidus, even years after the GBCA administration. The form of the storage (chelated or free), as well as their clinical impact, are not clear, but first observations of "gadolinium deposition disease" have been reported.
引用
收藏
页码:S1 / S7
页数:7
相关论文
共 50 条
  • [41] Safe and potent MRI contrast agents by complexing gadolinium with enzyme/reduction dual-sensitive branched polymers
    Wang, Xiaoming
    Guo, Shiwei
    Li, Zhiqian
    Xiao, Xueyang
    Gu, Lei
    Luo, Qiang
    Zhang, Hu
    Gong, Qiyong
    Luo, Kui
    APPLIED MATERIALS TODAY, 2019, 17 : 92 - 103
  • [42] Gadolinium-based contrast agents: From gadolinium complexes to colloidal systems
    Yon, Marjorie
    Billotey, Claire
    Marty, Jean-Daniel
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2019, 569
  • [43] Brain gadolinium deposition after administration of gadolinium-based contrast agents
    Tomonori Kanda
    Hiroshi Oba
    Keiko Toyoda
    Kazuhiro Kitajima
    Shigeru Furui
    Japanese Journal of Radiology, 2016, 34 : 3 - 9
  • [44] Brain gadolinium deposition after administration of gadolinium-based contrast agents
    Kanda, Tomonori
    Oba, Hiroshi
    Toyoda, Keiko
    Kitajima, Kazuhiro
    Furui, Shigeru
    JAPANESE JOURNAL OF RADIOLOGY, 2016, 34 (01) : 3 - 9
  • [45] Toxicity Mechanisms of Gadolinium and Gadolinium-Based Contrast Agents-A Review
    Coimbra, Susana
    Rocha, Susana
    Sousa, Nicia Reis
    Catarino, Cristina
    Belo, Luis
    Bronze-da-Rocha, Elsa
    Valente, Maria Joao
    Santos-Silva, Alice
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2024, 25 (07)
  • [46] Non-gadolinium-based MRI contrast agents
    Schwert, DD
    Davies, JA
    Richardson, N
    CONTRAST AGENTS I: MAGNETIC RESONANCE IMAGING, 2002, 221 : 165 - 199
  • [47] GADOLINIUM LABELED ANTIBODIES AS SPECIFIC CONTRAST AGENTS IN MRI
    MACRI, MA
    DELUCA, F
    MARAVIGLIA, B
    POLIZIO, F
    GARREFFA, G
    STELLA, A
    CAVALLO, S
    NATALI, PG
    MAGNETIC RESONANCE AND RELATED PHENOMENA, 1989, : 1041 - 1046
  • [48] GADOLINIUM COMPLEXES AS CONTRAST AGENTS FOR LIVER NMR IMAGING
    CONTI, F
    DELFINI, M
    SCOPINARO, F
    CROATTO, U
    INORGANICA CHIMICA ACTA, 1987, 140 (1-2) : 355 - 357