Implementation of uniform and simultaneous ART for 3-D reconstruction in an X-ray imaging system

被引:2
|
作者
Roh, YJ [1 ]
Cho, HS [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Mech Engn, Taejon 305701, South Korea
来源
关键词
D O I
10.1049/ip-vis:20040714
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The authors propose a 3-D volume reconstruction method using X-ray images with a calibration method to implement it in an X-ray imaging system. Previously the authors have proposed an advanced 3-D reconstruction algorithm based on an algebraic reconstruction technique (ART), called a uniform and simultaneous ART (USART). In practice, however, there are two main issues in implementing it in a realised X-ray imaging system. The first one is the huge computation time and memory required in achieving 3-D volume, which is a common limitation in most ART methods. The second issue is the system calibration for determining the geometry of the X-ray imaging conditions needed for the ART method. These two critical problems are addressed. A fast computing model of USART is proposed, where spherical voxel elements are employed in computation to reduce the computation time and memory. Then, a calibration method is proposed to identify the X-ray imaging geometry based on a cone beam projection model. For this purpose, a set of X-ray images of a reference grid pattern is used and the X-ray source positions are determined from the analysis of the image features, the centres of the grid points in the X-ray images. The validity of the proposed 3-D reconstruction method is investigated using a series of experiments.
引用
收藏
页码:360 / 368
页数:9
相关论文
共 50 条
  • [21] 3-D X-ray images of nanoparticles
    不详
    AMERICAN CERAMIC SOCIETY BULLETIN, 2007, 86 (02): : 27 - 27
  • [22] Testing and evaluation of an advanced (3-D) x-ray screening system
    Evans, JPO
    Robinson, M
    Lacey, D
    32ND ANNUAL 1998 INTERNATIONAL CARNAHAN CONFERENCE ON SECURITY TECHNOLOGY, 1998, : 50 - 54
  • [23] A 3-D X-ray microtomographic system with a CMOS image sensor
    Lee, SW
    Kim, HK
    Cho, G
    Shin, YH
    Won, YY
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1503 - 1505
  • [24] Deep X-ray exposure system with multistage for 3-D microfabrication
    You, H
    Matsuzuka, N
    Yamaji, T
    Tabata, O
    MHS 2000: PROCEEDINGS OF THE 2000 INTERNATIONAL SYMPOSIUM ON MICROMECHATRONICS AND HUMAN SCIENCE, 2000, : 53 - 58
  • [25] A review of geometric calibration for different 3-D X-ray imaging systems
    Yang, Yao
    Li, Liang
    Chen, Zhi-Qiang
    NUCLEAR SCIENCE AND TECHNIQUES, 2016, 27 (03)
  • [26] A review of geometric calibration for different 3-D X-ray imaging systems
    Yao Yang
    Liang Li
    Zhi-Qiang Chen
    Nuclear Science and Techniques, 2016, 27
  • [27] A 3-D Projection Model for X-ray Dark-field Imaging
    Felsner, Lina
    Hu, Shiyang
    Maier, Andreas
    Bopp, Johannes
    Ludwig, Veronika
    Anton, Gisela
    Riess, Christian
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [28] A review of geometric calibration for different 3-D X-ray imaging systems
    Yao Yang
    Liang Li
    Zhi-Qiang Chen
    NuclearScienceandTechniques, 2016, 27 (03) : 11 - 21
  • [29] A 3-D Projection Model for X-ray Dark-field Imaging
    Lina Felsner
    Shiyang Hu
    Andreas Maier
    Johannes Bopp
    Veronika Ludwig
    Gisela Anton
    Christian Riess
    Scientific Reports, 9
  • [30] Confocall micro X-ray fluorescence microscope: 3-D Elemental imaging
    Havrilla, GJ
    Hastings, E
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U184 - U184