Improvement of axial resolution for optical coherence tomography using a synthesized light source

被引:0
|
作者
Sato, M [1 ]
Wakaki, I [1 ]
Watanabe, Y [1 ]
Tanno, N [1 ]
机构
[1] Yamagata Univ, Yonezawa, Yamagata 9928510, Japan
关键词
optical coherence tomography; synthesized light source; coherence length;
D O I
10.1117/12.583033
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrated that a synthesized light source (SLS) consisting of two low coherence light sources is capable of enhancing spatial resolution in optical coherence tomography (OCT). The axial resolution of OCT is given by the half of coherence length of the light source. We fabricated an SLS with a coherence length of 2.3 mum and the side lobe intensity of 29 % under the intensity ratio of LED 1: LED 2 = 1: 0.4 by combining two light sources, LED 1 with a central wavelength of 700 nm and spectral bandwidth of 100 rim, and LED 2 of 898 nm and 85 nm. The coherence length of 2.3 Eun is 56% of the shorter coherence length in two LED's, therefore the axial resolution is 1.2 mum.
引用
收藏
页码:662 / 669
页数:8
相关论文
共 50 条
  • [21] Resolution improvement in optical coherence tomography by optimal synthesis of light-emitting diodes
    Zhang, Y
    Sato, M
    Tanno, N
    OPTICS LETTERS, 2001, 26 (04) : 205 - 207
  • [22] Ultrahigh resolution optical coherence tomography imaging with a broadband superluminescent diode light source
    Ko, TH
    Adler, DC
    Fujimoto, JG
    Mamedov, D
    Prokhorov, V
    Shidlovski, V
    Yakubovich, S
    OPTICS EXPRESS, 2004, 12 (10): : 2112 - 2119
  • [23] Enhancement of optical coherence tomography axial resolution by spectral shaping
    Sun, S
    Guo, JH
    Gao, JS
    Xue, P
    CHINESE PHYSICS LETTERS, 2002, 19 (10) : 1456 - 1458
  • [24] Axial resolution improvement by spectral data fusion in simultaneous dual-band optical coherence tomography
    Cimalla, Peter
    Gaertner, Maria
    Walther, Julia
    Koch, Edmund
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES V, 2011, 8091
  • [25] A thermal light source technique for optical coherence tomography
    Fercher, AF
    Hitzenberger, CK
    Sticker, M
    Moreno-Barriuso, E
    Leitgeb, R
    Drexler, W
    Sattmann, H
    OPTICS COMMUNICATIONS, 2000, 185 (1-3) : 57 - 64
  • [26] Axial resolution improvement in Spectral Domain Optical Coherence Tomography using a depth-adaptive maximum-a-posterior framework
    Boroomand, Ameneh
    Tan, Bingyao
    Wong, Alexander
    Bizheve, Kostadinka
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIX, 2015, 9312
  • [27] Improvement of axial resolution in optical coherence tomography by optical pupil filter - art. no. 65342T
    Zhou, Lin
    Ding, Zhihua
    Meng, Jie
    Zhou, Zhenming
    Fifth International Conference on Photonics and Imaging in Biology and Medicine, Pts 1 and 2, 2007, 6534 : T5342 - T5342
  • [28] Ultrasound induced improvement in optical coherence tomography (OCT) resolution
    Schenk, JO
    Brezinski, ME
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (15) : 9761 - 9764
  • [29] Resolution improvement in optical coherence tomography with segmented spectrum management
    Lu, CW
    Tsai, MT
    Wang, YM
    Kiang, YW
    Yang, CC
    OPTICAL AND QUANTUM ELECTRONICS, 2005, 37 (13-15) : 1165 - 1173
  • [30] Lateral Resolution Improvement in Optical Coherence Tomography (OCT) Images
    Bousi, Evgenia
    Pitris, Costas
    IEEE 12TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS & BIOENGINEERING, 2012, : 599 - 602