Corrosion of orthodontic wires according to heat treatment conditions

被引:3
|
作者
Oh, KT
Hwang, CJ
Park, YS
Kim, KN
机构
[1] Yonsei Univ, Coll Dent, Res Inst Dent Biomat & Bioengn, Seodaemun Gu, Seoul 120752, South Korea
[2] Yonsei Univ, Dept Met Engn, Seodaemun Gu, Seoul 120749, South Korea
[3] Yonsei Univ, Coll Dent, Dept Orthodont, Seodaemun Gu, Seoul 120752, South Korea
关键词
orthodontic wires; heat treatment; stress relief; corrosion resistance;
D O I
10.2320/matertrans.43.3078
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Heat treatments are applied to orthodontic wires in order to relieve the stresses arising during orthodontic work. Four types of wires were heated in air, argon or vacuum environments, and cooled in the furnace or in a water bath. The susceptibility to corrosion and mechanical properties of the heat-treated wires were investigated. Heat treatment marginally increased the yield strength and elastic modulus of all wires. After heat treatment in air, both water- and furnace-cooled wires had similar low corrosion resistances. Corrosion resistances of wires heated under vacuum differed significantly according to cooling methods, such that furnace-cooled wires had higher corrosion resistances than water-cooled wires. Water-cooled wires consistently showed low corrosion resistance whether heated in vacuum, argon, or air environments. After heat treatment under vacuum, furnace-cooled wires had low current densities and high pitting potentials similar to control wires, but other heat-treated wires generally exhibited high current densities and low pitting potentials. Wires heat-treated under vacuum or argon and then cooled in the furnace were the least susceptible to surface oxidation and corrosion, and showed a marginal improvement in mechanical properties. Therefore, we conclude that wires treated in these way can reduce metal ion release and wire fracture, which can minimize adverse effects arising from orthodontic practices.
引用
收藏
页码:3078 / 3082
页数:5
相关论文
共 50 条
  • [31] Influence of fluoride and chloride on corrosion behavior of NiTi orthodontic wires
    Li, Xiaoji
    Wang, Jianqiu
    Han, En-Hou
    Ke, Wei
    ACTA BIOMATERIALIA, 2007, 3 (05) : 807 - 815
  • [32] PROPERTIES OF SUPERELASTIC WIRES AND THEIR RELEVANCE TO ORTHODONTIC TREATMENT
    SEGNER, D
    IBE, D
    EUROPEAN JOURNAL OF ORTHODONTICS, 1995, 17 (05) : 395 - 402
  • [33] Effect of heat treatment on corrosion behavior of duplex stainless steel in orthodontic applications
    Hammood, Ali Sabea
    Noor, Ahmed Faraj
    Alkhafagy, Mohammed Talib
    MATERIALS RESEARCH EXPRESS, 2017, 4 (12):
  • [34] Effect of Direct Electric Resistance Heat Treatment on Mechanical Properties of NiTi Orthodontic Arch Wires
    Kiattiwongse, W.
    Khantachawana, A.
    Santiwong, P.
    SMART MATERIALS, 2008, 55-57 : 249 - +
  • [35] Corrosion resistance of stressed NiTi and stainless steel orthodontic wires.
    Huang, HH
    Chiu, YH
    Hsu, CC
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A487 - A487
  • [36] Stress corrosion cracking of NiTi orthodontic wires in sodium fluoride solution
    Li, Xiaoji
    Wang, Jianqiu
    Han, En-hou
    Ke, Wei
    FRONTIERS IN MATERIALS SCIENCE AND TECHNOLOGY, 2008, 32 : 79 - 82
  • [37] Effect of fluoride concentration on the corrosion behavior of NiTi orthodontic wires.
    Lin, S. -Y.
    Hsu, C. -C.
    Hsu, C. -H.
    Lee, T. -H.
    Chou, M. -Y.
    Huang, H. -H.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B341 - B341
  • [38] Corrosion-induced changes in surface properties and roughness of orthodontic wires
    Ique, Manuel Martin Adriazola
    Ferreira, Mayra Fernanda
    Delbem, Alberto Carlos Botazzo
    de Mendonca, Marcos Rogerio
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2024, 165 (05) : 565 - 575
  • [39] Corrosion resistance and mechanical properties of titanium nitride plating on orthodontic wires
    Sugisawa, Haruki
    Kitaura, Hideki
    Ueda, Kyosuke
    Kimura, Keisuke
    Ishida, Masahiko
    Ochi, Yumiko
    Kishikawa, Akiko
    Ogawa, Saika
    Takano-Yamamoto, Teruko
    DENTAL MATERIALS JOURNAL, 2018, 37 (02) : 286 - 292
  • [40] COMPARATIVE FRICTION OF ORTHODONTIC WIRES UNDER DRY AND WET CONDITIONS
    STANNARD, JG
    GAU, JM
    HANNA, MA
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1986, 89 (06) : 485 - 491