Optimization of b-value schemes for estimation of the diffusion coefficient and the perfusion fraction with segmented intravoxel incoherent motion model fitting

被引:36
|
作者
Jalnefjord, Oscar [1 ,2 ]
Montelius, Mikael [1 ]
Starck, Goran [1 ,2 ]
Ljungberg, Maria [1 ,2 ]
机构
[1] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiat Phys, Gothenburg, Sweden
[2] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, Gothenburg, Sweden
关键词
Cramer-Rao lower bound; diffusion-weighted imaging; error propagation; experiment design; IVIM; MRI; WEIGHTED MRI; IMPACT; IVIM; PRECISION; DESIGN; WATER;
D O I
10.1002/mrm.27826
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Intravoxel incoherent motion (IVIM) modeling for estimation of the diffusion coefficient (D) and perfusion fraction (f) is increasingly popular, but no consensus on standard protocols exists. This study provides a framework for optimization of b-value schemes for reduced estimation uncertainty of D and f from segmented model fitting. Theory: Analytical expressions for uncertainties of D and f from segmented model fitting were derived as Cramer-Rao lower bounds (CRLBs). Methods: Optimized b-value schemes were obtained for 3 to 12 acquisitions and in the limit of infinitely many acquisitions through constrained minimization of the CRLBs, with b-values constrained to be 0 or 200 to 800 s/mm(2). The optimized b-value scheme with eight acquisitions was compared with b-values linearly distributed in the allowed range using simulations and in vivo liver data from seven healthy volunteers. Results: All optimized b-value schemes contained exactly three unique b-values regardless of the total number of acquisitions (0, 200, and 800 s/mm(2)) with repeated acquisitions distributed approximately as 1:2:2. Compared with linearly distributed b-values, the variability of estimates of D and f was reduced by approximately 30% as seen both in simulations and in repeated in vivo measurements. Conclusion: The uncertainty of IVIM D and f estimates can be reduced by the use of optimized b-value schemes.
引用
收藏
页码:1541 / 1552
页数:12
相关论文
共 50 条
  • [21] Observed paradoxical perfusion fraction elevation in steatotic liver: An example of intravoxel incoherent motion modeling of the perfusion component constrained by the diffusion component
    Wang, Yi Xiang J.
    NMR IN BIOMEDICINE, 2021, 34 (04)
  • [22] A comparison of fitting algorithms for diffusion-weighted MRI data analysis using an intravoxel incoherent motion model
    Roberta Fusco
    Mario Sansone
    Antonella Petrillo
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2017, 30 : 113 - 120
  • [23] Depiction of the perfusion components' volume fraction distribution in generalized intravoxel incoherent motion by using Gaussian mixture model
    Wang, Shunli
    Liu, Wanyu
    Kuai, Zixiang
    Zhu, Yuemin
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2018, 48B (03)
  • [24] A comparison of fitting algorithms for diffusion-weighted MRI data analysis using an intravoxel incoherent motion model
    Fusco, Roberta
    Sansone, Mario
    Petrillo, Antonella
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (02) : 113 - 120
  • [25] TRI-EXPONENTIAL APPROACH FOR INTRAVOXEL INCOHERENT MOTION ANALYSISOF MULTI B-VALUE DIFFUSION WHEIGTED MRI DATA FOLLOWS GFR CHANGES IN HEALTHY HUMANS
    van der Bel, Rene
    Gurney-Champion, Oliver J.
    Froeling, Martijn
    Nederveen, Aart J.
    Krediet, C. T. Paul
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2016, 31 : 161 - 161
  • [26] Accurate intravoxel incoherent motion parameter estimation using Bayesian fitting and reduced number of low b-values
    Ye, Chen
    Xu, Daoyun
    Qin, Yongbin
    Wang, Lihui
    Wang, Rongpin
    Li, Wuchao
    Kuai, Zixiang
    Zhu, Yuemin
    MEDICAL PHYSICS, 2020, 47 (09) : 4372 - 4385
  • [27] Estimation of diffusion, perfusion and fractional volumes using a multi-compartment relaxation-compensated intravoxel incoherent motion (IVIM) signal model
    Rydhog, Anna
    Pasternak, Ofer
    Stahlberg, Freddy
    Ahlgren, Andre
    Knutsson, Linda
    Wirestam, Ronnie
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2019, 6 : 198 - 205
  • [28] Diagnostic Efficiency of Multi-b-Value Intravoxel Incoherent Motion Diffusion Weighted Imaging for Pulmonary Masses
    Zeng, Chun-Guang
    Zong, Deng-Wei
    Guo, Chen-Yang
    Li, Hai-Liang
    Cheng, Hong-Tao
    Liu, Jian
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (08) : 1677 - 1681
  • [29] Comparison of tri-exponential decay versus bi-exponential decay and full fitting versus segmented fitting for modeling liver intravoxel incoherent motion diffusion MRI
    Chevallier, Olivier
    Zhou, Nan
    Cercueil, Jean-Pierre
    He, Jian
    Loffroy, Romaric
    Wang, Yi Xiang J.
    NMR IN BIOMEDICINE, 2019, 32 (11)
  • [30] Head and Neck Tumors: Assessment of Perfusion-Related Parameters and Diffusion Coefficients Based on the Intravoxel Incoherent Motion Model
    Sumi, M.
    Nakamura, T.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (02) : 410 - 416