Detection of simulated interproximal lesions with storage phosphor imaging

被引:0
|
作者
Thomas, JA [1 ]
Simmons, JJ [1 ]
Kapa, SF [1 ]
Close, JM [1 ]
机构
[1] UNIV PITTSBURGH,SCH DENT MED,PITTSBURGH,PA
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
引用
收藏
页码:1686 / 1686
页数:1
相关论文
共 50 条
  • [1] Selenium radiography versus storage phosphor and conventional radiography in the detection of simulated chest lesions
    SchaeferProkop, CM
    Prokop, M
    Schmidt, A
    Neitzel, U
    Galanski, M
    RADIOLOGY, 1996, 201 (01) : 45 - 50
  • [2] Clinical SWIR and CP-OCT imaging of interproximal lesions
    Zhu, Yihua
    Le, Oanh
    Xue, Joany
    Wycoff, Spencer
    Fried, Daniel
    BMC ORAL HEALTH, 2024, 24 (01):
  • [3] Effects of calibration and automatic greyscale adjustment on detectability of simulated bone lesions using a storage phosphor system
    Versteeg, CH
    Sanderink, GCH
    van Ginkel, FC
    van der Stelt, PF
    DENTOMAXILLOFACIAL RADIOLOGY, 1998, 27 (04) : 240 - 244
  • [4] DETECTION OF SIMULATED CHEST LESIONS - COMPARISON OF A CONVENTIONAL SCREEN-FILM COMBINATION, AN ASYMMETRIC SCREEN-FILM SYSTEM, AND STORAGE PHOSPHOR RADIOGRAPHY
    LEPPERT, AGA
    PROKOP, M
    SCHAEFERPROKOP, CM
    GALANSKI, M
    RADIOLOGY, 1995, 195 (01) : 259 - 263
  • [5] A comparison of high resolution storage phosphor radiographs (4K) and selenium radiographs (2K) in the detection of simulated chest lesions
    SchaeferProkop, CM
    Prokop, M
    Bolooreki, K
    Schmidt, A
    Kausche, H
    Siemund, R
    RADIOLOGY, 1997, 205 : 1252 - 1252
  • [6] Intravascular Imaging with Storage Phosphor Detector
    Shikhaliev, P. M.
    Petrek, P.
    Fritz, S. G.
    Matthews, K. L.
    Bujenovic, S.
    Xu, T.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [7] Intravascular imaging with a storage phosphor detector
    Shikhaliev, Polad M.
    Petrek, Peter
    Matthews, Kenneth L., II
    Fritz, Shannon G.
    Bujenovic, L. Steven
    Xu, Tong
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (10): : 2841 - 2861
  • [8] ROC Analysis of Storage Phosphor Radiography and Digital Selenium Radiography at Various Tube Voltages in Simulated Chest Lesions
    Cho, Hyo-Min
    Kim, Hee-Joung
    Lee, Chang-Lae
    Jung, Ji-Young
    Park, Hye-Suk
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4825 - 4829
  • [9] Detection of simulated interstitial lung disease and catheters with selenium, storage phosphor, and film-based radiography
    Bernhardt, TM
    Otto, D
    Reichel, G
    Ludwig, K
    Seifert, S
    Kropf, S
    Rapp-Bernhardt, U
    RADIOLOGY, 1999, 213 (02) : 445 - 454
  • [10] IMAGING PERFORMANCE OF A DIGITAL STORAGE PHOSPHOR SYSTEM
    HILLEN, W
    SCHIEBEL, U
    ZAENGEL, T
    MEDICAL PHYSICS, 1987, 14 (05) : 744 - 751