ELIMINATION OF DEAD-END OSCILLATIONS OF COMPRESSOR MANUFACTORY PIPING IN OPERATING CONDITIONS

被引:2
|
作者
Buranshin, Aydar R. [1 ]
Godovskiy, Dmitriy A. [1 ]
Tokarev, Artem P. [1 ]
机构
[1] Ufa State Petr Technol Univ, 1 Kosmonavtov St, Ufa 450062, Russia
关键词
Piping; hydraulic calculation; process piping; dead-end oscillations; vibration; gas pulsation; compressor manufactory;
D O I
10.18799/24131830/2019/9/2268
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The relevance of research. At present, the role of activities aimed to improving the reliability of equipment in the main pipeline transport of natural gas is growing. The factor that negatively affects the reliability of operation of compressor stations equipment of main gas pipelines is the increased vibration due to various reasons. One of these reasons is the combination of certain geometric dimensions of pipelines and high flow of process gas. The aim of the research is to define the modes of a compressor manufactory with 8 full -pressure units to reduce the intensive deadend oscillation observed in off-cycle compressor units' piping. Object pipeline communications section of the compressor station from the cyclone dust collectors to the inlet manifold of the compressor manufactory, tees with branches to the gas -pumping unit, switched off by cranes No. 1 from the inlet manifold. Methods: vibration diagnostics of piping at the existing compressor station; mathematical modeling of operating modes of the compressor manufactory using a numerical solution (hydraulic calculation in combination with the calculation of natural frequencies and frequencies of the driving force). Findings. The paper proposes a method for eliminating dead-end oscillations within the scope of operation, specifying the requirements of regulatory documentation. The methodology for estimating the conditions of dead-end oscillations appearance is developed. It is based on the hydraulic calculation of a high-pressure loop gas pipeline with selections. Two modes of a compressor manufactory vvith 8 full -pressure units vvith a capacity of 100 million mi,/ day are considered to detuning from resonance. As a result of the calculations, the number of gas -pumping units from the edge of the compressor manufactory, that must be operated to eliminate dead-end oscillations, has been reduced in comparison with the recommendations of normative documentation. This allows putting the second gas -pumping unit from the edge of the compressor manufactory into reserve and, consequently, reducing the operating time of this gas -pumping unit while eliminating the high dead-end oscillations of the piping.
引用
收藏
页码:164 / 171
页数:8
相关论文
共 50 条
  • [11] The Dead-End Elimination method, tryptophan rotamers, and fluorescence lifetimes
    Hellings, M
    De Maeyer, M
    Verheyden, S
    Hao, Q
    Van Damme, EJM
    Peumans, WJ
    Engelborghs, Y
    BIOPHYSICAL JOURNAL, 2003, 85 (03) : 1894 - 1902
  • [12] SIDE-CHAIN PLACEMENT BY THE DEAD-END AND FUZZY-END ELIMINATION
    KELLER, DA
    SHIBATA, M
    MANCHESTER, JI
    ORNSTEIN, RL
    REIN, R
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 64 - COMP
  • [13] Dead-end elimination as a heuristic for min-cut image segmentation
    Radhakrishnan, Mala L.
    Su, Sara L.
    2006 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP 2006, PROCEEDINGS, 2006, : 2429 - +
  • [14] Numerical simulation of colloid dead-end filtration: Effect of membrane characteristics and operating conditions on matter accumulation
    Bessiere, Yolaine
    Fletcher, David F.
    Bacchin, Patrice
    JOURNAL OF MEMBRANE SCIENCE, 2008, 313 (1-2) : 52 - 59
  • [15] Dead-End Elimination with a Polarizable Force Field Repacks PCNA Structures
    LuCore, Stephen D.
    Litman, Jacob M.
    Powers, Kyle T.
    Gao, Shibo
    Lynn, Ava M.
    Tollefson, William T. A.
    Fenn, Timothy D.
    Washington, M. Todd
    Schnieders, Michael J.
    BIOPHYSICAL JOURNAL, 2015, 109 (04) : 816 - 826
  • [16] Restricted Dead-End Elimination: Protein Redesign with a Bounded Number of Residue Mutations
    Safi, Maria
    Lalien, Ryan H.
    JOURNAL OF COMPUTATIONAL CHEMISTRY, 2010, 31 (06) : 1207 - 1215
  • [17] Effect of operating parameters on the separation of proteins in aqueous solutions by dead-end ultrafiltration
    Lin, Su-Hsia
    Hung, Chia-Lin
    Juang, Ruey-Shin
    DESALINATION, 2008, 234 (1-3) : 116 - 125
  • [18] Comparison of dead-end and continuous filtration conditions in a denitrification membrane bioreactor
    McAdam, E. J.
    Cartmell, E.
    Judd, S. J.
    JOURNAL OF MEMBRANE SCIENCE, 2011, 369 (1-2) : 167 - 173
  • [19] Optimisation of dead-end filtration conditions for an immersed anoxic membrane bioreactor
    McAdam, E. J.
    Judd, S. J.
    JOURNAL OF MEMBRANE SCIENCE, 2008, 325 (02) : 940 - 946
  • [20] Exploring the conformational space of protein side chains using dead-end elimination and the A* algorithm
    Leach, AR
    Lemon, AP
    PROTEINS-STRUCTURE FUNCTION AND BIOINFORMATICS, 1998, 33 (02) : 227 - 239