Identification of three novel mutations in Japanese patients with Menkes disease and mutation screening by denaturing high performance liquid chromatography

被引:5
|
作者
Watanabe, A [1 ]
Shimizu, N [1 ]
机构
[1] Toho Univ, Sch Med, Ohashi Hosp, Dept Pediat 2,Meguro Ku, Tokyo 1538515, Japan
关键词
ATP7A; denaturing high performance liquid chromatography; inborn error of copper metabolism; Menkes disease; molecular diagnosis;
D O I
10.1111/j.1442-200x.2004.02012.x
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: Menkes disease is an X-linked recessive disorder resulting in a connective-tissue disturbance and profound neurodegeneration in early childhood. The gene for Menkes disease has been isolated and predicted to code for copper transporting ATPase. In this study, a mutation analysis in Japanese patients with Menkes disease was performed, as was a mutation screening by denaturing high performance liquid chromatography (DHPLC). Methods: A mutation analysis on five Japanese patients with Menkes disease was performed using a direct sequencing method and DHPLC. Results: Two nonsense mutations, two missense mutations and one splice donor site mutation were found. The DHPLC analysis showed differences in the peaks between the DNA fragments of wild type and heteroduplex (wild type and mutant). Conclusions: Three novel mutations (Asp1044Gly, Pro1279Leu and IVS21+1 g to a) were detected. The Asp1044Gly mutation destroys the highly conserved phosphorylation domain in exon 16. The splice site abnormality leads to a skipping of exon 21 coding for part of the seventh transmembrane domain. These two mutations could cause a severe protein dysfunction. Another missense mutation, Pro1279Leu, in exon 20 was found in a patient with a mild type of Menkes disease. It is speculated that this mutation partially maintains the ATP7A function is. A DHPLC analysis could detect these mutations. It is concluded that the best way to make a molecular diagnosis for Menkes disease is to first screen DNA samples for all exons using DHPLC, and thereafter perform direct sequencing for exons which have an abnormal elution profile in order to rapidly detect such mutations.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [31] Denaturing high performance liquid chromatography (dHPLC) for mutation detection in the nebulin gene
    Lehtokari, VL
    Pelin, K
    Sandbacka, M
    Ahola, A
    Turunen, M
    Wallgren-Pettersson, C
    NEUROMUSCULAR DISORDERS, 2005, 15 (9-10) : 693 - 693
  • [32] A novel denaturing high-performance liquid chromatography (D-HPLC) based method for kit mutation screening of patients (pts) with systemic mastocytosis (SM)
    Colarossi, S.
    Soverini, S.
    Gnani, A.
    Rondoni, M.
    Gatto, S.
    Merante, S.
    Zanotti, R.
    Martinelli, G.
    Baccarani, M.
    Tiribelli, M.
    JOURNAL OF CLINICAL ONCOLOGY, 2007, 25 (18)
  • [33] Identification of two novel mutations in the 5′ untranslated region of H-ferritin using denaturing high performance liquid chromatography scanning
    Cremonesi, L
    Foglieni, B
    Fermo, I
    Cozzi, A
    Paroni, R
    Ruggeri, G
    Belloli, S
    Levi, S
    Fargion, S
    Ferrari, M
    Arosio, P
    HAEMATOLOGICA, 2003, 88 (10) : 1110 - 1116
  • [34] A novel denaturing-high performance liquid chromatography (D-HPLC)based method for kit mutation screening of patients (PTS) with systemic mastocytosis (SM)
    Colarossi, S.
    Soverini, S.
    Gnani, A.
    Rondoni, M.
    Zanotti, R.
    Merante, S.
    Gatto, S.
    Tiribelli, M.
    Musto, F.
    Gottardi, E.
    Cilloni, D.
    Martinelli, G.
    Baccarani, M.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2007, 92 : 41 - 41
  • [35] Denaturing High-performance Liquid Chromatography mutation analysis in patients with reduced Protein S levels
    Bathum, Lise
    Muenster, Anna-Marie
    Nybo, Mads
    Madsen, Jonna Skov
    Larsen, Torben Bjerregaard
    Kristensen, Soren Risom
    CLINICA CHIMICA ACTA, 2008, 390 (1-2) : 76 - 81
  • [36] Denaturing high performance liquid chromatography (DHPLC) for PMM2 mutation screening in CDG type 1A patients.
    Uller, A
    Stibler, H
    Kristiansson, B
    Wahlstrom, J
    Martinsson, T
    AMERICAN JOURNAL OF HUMAN GENETICS, 1999, 65 (04) : A410 - A410
  • [37] Use of denaturing high performance liquid chromatography (dHPLC) for detection of EGFR mutations in patients with NSCLC.
    Agulnik, J. S.
    Cohen, V.
    Jarry, J.
    Batist, G.
    Small, D.
    Kreisman, H.
    Tejada, N. A.
    Chong, G.
    Miller, W. H., Jr.
    JOURNAL OF CLINICAL ONCOLOGY, 2006, 24 (18) : 557S - 557S
  • [38] Molecular pathology of copper metabolism: Mutation screening in the ATP7A gene in Czech patients with Menkes disease - identification of two novel mutations
    Kralik, L
    Flachsova, E
    Zeman, J
    Martasek, P
    FASEB JOURNAL, 2006, 20 (04): : A98 - A98
  • [39] NF2 mutation screening by denaturing high-performance liquid chromatography and high-resolution melting analysis
    Sestini, Roberta
    Provenzano, Aldesia
    Bacci, Costanza
    Orlando, Claudio
    Genuardi, Maurizio
    Papi, Laura
    GENETIC TESTING, 2008, 12 (02): : 311 - 318
  • [40] Assessment of denaturing high-performance liquid chromatography (DHPLC) in screening for mutations in connexin 26 (GJB2)
    Lin, D
    Goldstein, JA
    Mhatre, AN
    Lustig, LR
    Pfister, M
    Lalwani, AK
    HUMAN MUTATION, 2001, 18 (01) : 42 - 51