Monitoring plasma cardiac troponin I for the detection of myocardial injury after percutaneous transluminal coronary angioplasty

被引:9
|
作者
Ricchiuti, V
Shear, WS
Henry, TD
Paulsen, PR
Miller, EA
Apple, FS
机构
[1] Univ Minnesota, Hennepin Cty Med Ctr, Sch Med, Dept Lab Med & Pathol, Minneapolis, MN 55415 USA
[2] Univ Minnesota, Hennepin Cty Med Ctr, Sch Med, Dept Med, Minneapolis, MN 55415 USA
关键词
angioplasty; cardiac troponin; myocardial damage;
D O I
10.1016/S0009-8981(00)00365-X
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The objective of this study was to detect myocardial injury defined by an increase of plasma cardiac troponin I (cTnI) following percutaneous transluminal coronary angioplasty (PTCA) and compare plasma cTnI with the risk of cardiac complications at 30 days. Plasma cTnI, creatine kinase (CR) MB, and total CK were determined in 83 patients before (baseline) and 6, 12 and 24 h after PTCA. Thirty-eight patients underwent conventional PTCA, 39 PTCA-stent and six rotational atherectomy. Patients with acute myocardial infarction (AMI) and increased preprocedural cTnI > 0.8 mug/l were categorized into group 1 (n = 23). The remaining 60 patients (pre-procedural cTnI = 0.8 mug/l) were categorized as follows: group 2 (n = 15) AMI; group 3 (n = 20) unstable angina (UA); group 4 (n = 25) coronary artery disease (CAD). Twelve hours post-procedure, all three cardiac markers were more frequently increased over baseline in group 2 patients (40-60%) compared to patients in group 3 (5-29%, P < 0.03) or group 4 (0.5-5%, P < 0.01). This was also true for patients undergoing PTCA-stent compared to conventional PTCA or rotational atherectomy (27-40 vs. 4-14%, P < 0.02). cTnI was more sensitive (60%) to detect release of myocardial protein after PTCA compared to total CK (47%) or CKMB (43%). A moderate increase of cTnl (0.8-1.5 <mu>g/l) in groups 2, 3 and 4 was associated with higher risk of complications 30 days post-procedure. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:161 / 170
页数:10
相关论文
共 50 条
  • [41] SEPTIC COMPLICATIONS AFTER CARDIAC-CATHETERIZATION AND PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    MCCREADY, RA
    SIDERYS, H
    PITTMAN, JN
    HEROD, GT
    HALBROOK, HG
    FEHRENBACHER, JW
    BECKMAN, DJ
    HORMUTH, DA
    JOURNAL OF VASCULAR SURGERY, 1991, 14 (02) : 170 - 174
  • [42] Cardiac release and kinetics of endothelin after uncomplicated percutaneous transluminal coronary angioplasty
    Krüger, D
    Giannitsis, E
    Sheikhzadeh, A
    Stierle, U
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (12): : 1421 - 1426
  • [43] EXCIMER LASER CORONARY ANGIOPLASTY AFTER FAILED PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    OZBEK, C
    WOLK, T
    BACH, R
    DYCKMANS, J
    SCHIEFFER, H
    ZEITSCHRIFT FUR KARDIOLOGIE, 1992, 81 (03): : 152 - 156
  • [44] IATROGENIC CORONARY STENOSIS AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    QUIRET, JC
    REMOND, A
    JARRY, G
    AVINEE, P
    CAZE, F
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1990, 83 (03): : 385 - 391
  • [45] NORMALIZATION OF CORONARY VASOMOTION AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    SUTER, TM
    BUECHI, M
    HESS, OM
    HAEMMERLISANER, C
    GAGLIONE, A
    KRAYENBUEHL, HP
    CIRCULATION, 1992, 85 (01) : 86 - 92
  • [46] FREQUENCY OF UNFAVORABLE CARDIAC EVENTS DOCUMENTED BY ROUTINE TELEMETRY MONITORING AFTER UNCOMPLICATED PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    JONES, EB
    MARSHALL, E
    ORNATO, JP
    ROMHILT, DW
    VETROVEC, GW
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (13): : 1229 - 1230
  • [47] Coronary artery vasomotion after percutaneous transluminal coronary angioplasty
    Misra, VK
    Agirbasli, M
    Fischell, TA
    CLINICAL CARDIOLOGY, 1997, 20 (11) : 915 - 922
  • [48] ECHOCARDIOGRAPHIC DETECTION OF ACUTE MYOCARDIAL-ISCHEMIA DURING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    HERREGODS, MC
    VANDEPLAS, A
    VROLIX, M
    DESCHEERDER, I
    PIESSENS, J
    AUBERT, A
    DEGEEST, H
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1993, 10 (02): : 133 - 139
  • [49] Cardiac troponin T, creatine kinase, and its isoform release after successful percutaneous transluminal coronary angioplasty with or without stenting
    Shyu, KG
    Kuan, PL
    Cheng, JJ
    Hung, CR
    AMERICAN HEART JOURNAL, 1998, 135 (05) : 862 - 867
  • [50] Detection of acute myocardial ischemia during percutaneous transluminal coronary angioplasty by endocardial acceleration
    Theres, HP
    Kaiser, DR
    Nelson, SD
    Glos, M
    Leuthold, T
    Baumann, G
    Sowelam, S
    Sheldon, TJ
    Stylos, L
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (05): : 621 - 625