A hybrid process for leachate wastewater treatment: Evaporation and reverse osmosis/sequencing batch reactor

被引:9
|
作者
Bouchareb, Raouf [1 ]
Isik, Zelal [2 ]
Ozay, Yasin [3 ]
Karagunduz, Ahmet [4 ]
Keskinler, Bulent [4 ]
Dizge, Nadir [2 ]
机构
[1] Saleh Boubnider Univ, Proc Engn Fac, Dept Environm Engn, Constantine, Algeria
[2] Mersin Univ, Dept Environm Engn, TR-33343 Mersin, Turkey
[3] Tarsus Univ, Vocat Sch Tech Sci Mersin Tarsus Organized Ind Zo, Dept Environm Protect Technol, Mersin, Turkey
[4] Gebze Tech Univ, Dept Environm Engn, Kocaeli, Turkey
关键词
biological treatment; evaporation; leachate; reverse osmosis membrane; LANDFILL LEACHATE; BIOLOGICAL TREATMENT; RECIRCULATION; REMOVAL;
D O I
10.1002/wer.10717
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, a hybrid process for leachate wastewater treatment including evaporation and reverse osmosis (RO) membrane or biological treatment systems was suggested. Experiments were performed on a real landfill leachate wastewater. The leachate was subjected to evaporation; as a result, a distillate was obtained containing less organic matter and less substantial amounts of other pollutants, as ammonium salts and total phenols were removed. Tests were carried out at different evaporation temperatures and times. The initial leachate pH was adjusted and optimized. For optimum conditions, each of chemical oxygen demand (COD), total phenol, and ammonium salt concentrations were reduced to 99.99%, 95.00%, and 83.00%, respectively. The distillate of the first stage of the proposed process was then exposed to RO membrane system, as a first study, under different transmembrane pressure of 20, 30, and 40 bar and at different pH values of 7, 8, and 9. As a second suggested treatment system, the distillate was subjected to a biological treatment process for 30 days as a retention time, pH = 6, and room temperature 25 degrees C +/- 1 degrees C. At the end of the research study, a comparison was conducted between results obtained with RO membrane separation and biological treatment system as two distinct treatment systems proposed for leachate landfill wastewater treatment. Although both systems were effective for landfill leachate wastewater treatment, however, with the RO membrane separation system, COD removal efficiency reached 99.99%. In the other hand, with biological treatment process, COD elimination was as much as 90.00%. Certainly, evaporation and RO are not novel ways of landfill leachate treatment; however, few studies have attempted to use similar combined system for landfill leachate wastewater treatment and attained effective results of treated water. Practitioner Points A hybrid process of evaporation and RO membrane or biological treatment systems was suggested for leachate wastewater treatment. For optimum conditions, COD, total phenols, and ammonium salt reductions were achieved to 99.99%, 95%, and 83%, respectively, after the first evaporation stage. The distillate of the first stage of the proposed process was then exposed to RO membrane system and biological treatment system. Different transmembrane pressure and different pH values were optimized for RO.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Performance of integrated sequencing batch reactor (SBR) and reverse osmosis (RO) process for leachate treatment: effect of pH
    Izabela Anna Tałałaj
    Journal of Environmental Health Science and Engineering, 2022, 20 : 419 - 429
  • [2] Performance of integrated sequencing batch reactor (SBR) and reverse osmosis (RO) process for leachate treatment: effect of pH
    Talalaj, Izabela Anna
    JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2022, 20 (01) : 419 - 429
  • [3] TREATMENT OF MUNICIPAL LANDFILL LEACHATE BY THE PROCESS OF REVERSE OSMOSIS AND EVAPORATION
    Sir, Marek
    Honzajkova, Zuzana
    FRESENIUS ENVIRONMENTAL BULLETIN, 2015, 24 (6A): : 2245 - 2250
  • [4] Hybrid System of Fenton Process and Sequencing Batch Reactor for Coking Wastewater Treatment
    Grosser, Anna
    Neczaj, Ewa
    Krzeminska, Dorota
    Ratman-Klosinska, Izabela
    WATER, 2025, 17 (05)
  • [5] Treatment of landfill leachate by sequencing batch reactor
    Neczaj, E
    Okoniewska, E
    Kacprzak, M
    DESALINATION, 2005, 185 (1-3) : 357 - 362
  • [6] Anaerobic treatment of leachate using sequencing batch reactor and hybrid bed filter
    Timur, H
    Ozturk, I
    WATER SCIENCE AND TECHNOLOGY, 1997, 36 (6-7) : 501 - 508
  • [7] Treatment of industrial landfill leachate by means of evaporation and reverse osmosis
    Di Palma, L
    Ferrantelli, P
    Merli, C
    Petrucci, E
    WASTE MANAGEMENT, 2002, 22 (08) : 951 - 955
  • [8] Sequencing batch reactor system for the co-treatment of landfill leachate and dairy wastewater
    Neczaj, Ewa
    Kacprzak, Malgorzata
    Kamizela, Tomasz
    Lach, Joanna
    Okoniewska, Ewa
    DESALINATION, 2008, 222 (1-3) : 404 - 409
  • [9] Hybrid of Fenton and sequencing batch reactor for petroleum refinery wastewater treatment
    Diya'uddeen, B. H.
    Pouran, Shima Rahim
    Aziz, A. R. Abdul
    Nashwan, S. M.
    Daud, Wan Mohd Ashri Wan
    Shaaban, M. G.
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2015, 25 : 186 - 191
  • [10] Anaerobic sequencing batch reactor treatment of landfill leachate
    Timur, H
    Özturk, I
    WATER RESEARCH, 1999, 33 (15) : 3225 - 3230