Amperometric sensor used for determination of thiocyanate with a silver nanoparticles modified electrode

被引:43
|
作者
Wang, GF
Li, MG
Gao, YC
Fang, B [1 ]
机构
[1] Anhui Normal Univ, Sch Chem, Wuhu 241000, Peoples R China
[2] Anhui Normal Univ, Sch Mat Sci, Wuhu 241000, Peoples R China
来源
SENSORS | 2004年 / 4卷 / 09期
关键词
silver nanoparticles; modified electrode; thiocyanate determination;
D O I
10.3390/s40900147
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel electrode modified with silver nanoparticles was fabricated. It is found that the reducibility of silver nanoparticles is higher than for bulk silver by comparing a silver nanoparticles modified electrode with a silver micro-disk electrode. When SCN- was added, a new oxidation peak occurred and the anodic peak current of silver nanoparticles decreased. The new anodic peak current is proportional to the thiocyanate concentration in the range of 5.0 x 10(-7) similar to4.0 x 10(-4) mol/L in pH 6.0 NaH2PO4-Na2HPO4 buffer solutions (PBS). The detection limit (S/N=3) is 4 x 10(-8) mol/L. This method has been applied to the determination of saliva (smoker and non-smoker).
引用
收藏
页码:147 / 155
页数:9
相关论文
共 50 条
  • [31] Amperometric Sensor for Hydrazine Determination Based on Mechanically Immobilized Nickel Hexacyanoferrate Modified Electrode
    D. R. Shankaran
    S. S. Narayanan
    Russian Journal of Electrochemistry, 2001, 37 : 1149 - 1153
  • [32] Amperometric aptasensing of chloramphenicol at a glassy carbon electrode modified with a nanocomposite consisting of graphene and silver nanoparticles
    Shun Liu
    Guosong Lai
    Haili Zhang
    Aimin Yu
    Microchimica Acta, 2017, 184 : 1445 - 1451
  • [33] Amperometric aptasensing of chloramphenicol at a glassy carbon electrode modified with a nanocomposite consisting of graphene and silver nanoparticles
    Liu, Shun
    Lai, Guosong
    Zhang, Haili
    Yu, Aimin
    MICROCHIMICA ACTA, 2017, 184 (05) : 1445 - 1451
  • [34] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF THIOCYANATE AND SELENOCYANATE AT A COBALT PHTHALOCYANINE MODIFIED CARBON-PASTE ELECTRODE
    COOKEAS, EG
    EFSTATHIOU, CE
    ANALYST, 1994, 119 (07) : 1607 - 1612
  • [35] Amperometric sensor based on tricobalt tetroxide nanoparticles-graphene nanocomposite film modified glassy carbon electrode for determination of tyrosine
    Jiang, Lin
    Gu, Shuqing
    Ding, Yaping
    Ye, Daixin
    Zhang, Zhen
    Zhang, Fenfen
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 107 : 146 - 151
  • [36] Polyaniline-modified electrode as an amperometric ascorbate sensor
    Jureviciute, I
    Brazdziuviene, K
    Bernotaite, L
    Salkus, B
    Malinauskas, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 107 (02): : 716 - 721
  • [37] IMMOBILIZED ENZYME CHEMICALLY MODIFIED ELECTRODE AS AN AMPEROMETRIC SENSOR
    IANNIELLO, RM
    YACYNYCH, AM
    ANALYTICAL CHEMISTRY, 1981, 53 (13) : 2090 - 2095
  • [38] A method for determination of glucose by an amperometric bienzyme biosensor based on silver nanocubes modified Au electrode
    Yang, Penghao
    Wang, Lisha
    Wu, Qi
    Chen, Zhichun
    Lin, Xianfu
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 194 : 71 - 78
  • [39] Ferromagnetic iron oxide nanoparticles modified electrode as a sensor for determination of nitrite
    Zhang J.
    Huang G.
    Ouyang H.
    Shi B.
    Sensor Letters, 2016, 14 (08) : 751 - 755
  • [40] Gold Nanoparticles Modified Polypyrrole/Iron Electrode Used as Sensor for Hydrazine Detection
    Oukil, D.
    Benhaddad, L.
    Makhloufi, L.
    Aitout, R.
    Saidani, B.
    SENSOR LETTERS, 2013, 11 (02) : 395 - 404