Monte Carlo Dose Estimation in Patient-Specific Volume Mesh From CT Images

被引:0
|
作者
Morato, S. [1 ]
Miro, R. [1 ]
Juste, B. [1 ]
Verdu, G. [1 ]
Santos, A. [2 ]
机构
[1] Univ Politecn Valencia, ISIRYM, Inst Ind Radiophys & Environm Safety, Cami Vera S-N, E-46022 Valencia, Spain
[2] Consorci Hosp Prov Castello, Avda Doctor Clara 19, Castellon de La Plana 12002, Spain
关键词
Radiotherapy; dose; MCNP; mesh; mosfet;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Radiation treatments are in continuous evolution and the use of increasingly advanced technologies enables personalized treatments. According to this, the work presented is focused on the 3D computed reconstruction of segmented CT images taken from an anthropomorphic phantom (RANDO phantom) using unstructured meshes. This phantom model is used to simulate dose distribution during a beam irradiation with Monte Carlo code. Searching for the most appropriate and rapid methodology for meshing the segmented phantom is the main goal of the present work. The use of different coupled softwares, as image segmentation software or meshing geometry software were necessary. Besides, several FORTRAN routines were coded for conversion formatting to Monte Carlo code and dose calculation. This study has used the last version of MCNP (v.6.1.1) Monte Carlo code to simulate a RANDO phantom irradiation. This new code version presents a new tool to improve geometry description by the importation of meshed models. The generated meshed head model is included in a Monte Carlo model of photon beam transport emitted by a medical LINear ACcelerator (LinAc). Results have been compared with values obtained by experimental measurements in different positions inside the phantom using High-Sensitivity MOSFET (Metal Oxide Semiconductor Field Effect Transistor) dosimeters. Monte Carlo results are in good agreement with experimental values, which demonstrate the validity and accuracy of the Monte Carlo method to estimate dose. The innovation of using meshed geometries in these calculations, shows an important advantage defining complex geometries as human anatomy.
引用
收藏
页码:1590 / 1593
页数:4
相关论文
共 50 条
  • [31] Real-time estimation of patient-specific dose distributions for medical CT using the deep dose estimation
    Maier, Joscha
    Klein, Laura
    Eulig, Elias
    Sawall, Stefan
    Kachelriess, Marc
    [J]. MEDICAL PHYSICS, 2022, 49 (04) : 2259 - 2269
  • [32] Estimating Specific Patient Organ Dose for Chest CT Examinations with Monte Carlo Method
    Yang, Yang
    Zhuo, Weihai
    Zhao, Yiyang
    Xie, Tianwu
    Wang, Chuyan
    Liu, Haikuan
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (19):
  • [33] Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography
    Deak, Paul
    van Straten, Marcel
    Shrimpton, Paul C.
    Zankl, Maria
    Kalender, Willi A.
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (04) : 759 - 772
  • [34] Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography
    Paul Deak
    Marcel van Straten
    Paul C. Shrimpton
    Maria Zankl
    Willi A. Kalender
    [J]. European Radiology, 2008, 18 : 759 - 772
  • [35] Towards clinical patient-specific Monte Carlo dose calculations for brachytherapy: egs_brachy developments
    Moghadam, Narjes
    Martinov, Martin
    Jarvis, Shannon
    Zhang, Claire
    Ouellet, Samuel
    Thibodeau, Michael
    Cygler, Joanna
    Hilts, Michelle
    Beaulieu, Luc
    Thomson, Rowan
    [J]. MEDICAL PHYSICS, 2022, 49 (08) : 5700 - 5700
  • [36] PATIENT-SPECIFIC MONTE CARLO DOSE CALCULATIONS FOR HIGH-DOSE-RATE ENDORECTAL BRACHYTHERAPY WITH SHIELDED INTRACAVITARY APPLICATOR
    Poon, Emily
    Williamson, Jeffrey F.
    Vuong, Te
    Verhaegen, Frank
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04): : 1259 - 1266
  • [37] Patient-specific SRS QA using the PRIMO Monte Carlo software
    Calvo Ortega, J. F.
    Hermida-Lopez, M.
    Moragues-Femenia, S.
    Laosa-Bello, C.
    Casals-Farran, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S1038 - S1039
  • [38] Phantom-and patient-specific dose calculations for CT
    Schmidt, B
    Kalender, WA
    [J]. RADIOLOGY, 2002, 225 : 592 - 592
  • [39] Patient-specific QA for CyberKnife MLC plans using Monte Carlo
    Mackeprang, P. H.
    Vuong, D.
    Volken, W.
    Henzen, D.
    Schmidhalter, D.
    Malthaner, M.
    Mueller, S.
    Frei, D.
    Aebersold, D. M.
    Fix, M. K.
    Manser, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S791 - S791
  • [40] Treatment plan prescreening for patient-specific quality assurance measurements using independent Monte Carlo dose calculations
    Xu, Yuan
    Zhang, Ke
    Liu, Zhiqiang
    Liang, Bin
    Ma, Xiangyu
    Ren, Wenting
    Men, Kuo
    Dai, Jianrong
    [J]. FRONTIERS IN ONCOLOGY, 2022, 12