External dose evaluation based on detailed air dose rate measurements in living environments

被引:12
|
作者
Sato, Tetsuro [1 ]
Andoh, Masaki [2 ]
Sato, Masako [3 ]
Saito, Kimiaki [2 ]
机构
[1] Hitachi Solut East Japan Lai, Aoba Ku, Metlife Sendai Honcho Bldg,2-16-10 Honcho, Sendai, Miyagi 9800014, Japan
[2] Japan Atom Energy Agcy, 11601-13 Nishi Jusanbugyo, Hitachinaka, Ibaraki 3191206, Japan
[3] Tokyo Records Management Co Inc, BR Gotanda, 2-30-4 Nishi Gotanda, Shinagawa, Tokyo 1410031, Japan
关键词
External dose; Returning residents; Evacuation order; Interview of life pattern; KURAMA-II; Fukushima dai-ichi nuclear power plant accident; Air dose; CONVERSION COEFFICIENTS;
D O I
10.1016/j.jenvrad.2019.05.005
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A method was devised to estimate the realistic external doses of residents expected to return to their homes after evacuation orders are lifted. For 196 residents expected to return to six towns and villages, surveys were administered in FY 2014-2016. After interviewing residents about their expected life patterns after their return, detailed air dose rate measurements were taken along their reported personal routes representing patterns of movement in their daily life. The maximum and average annual additional external effective dose were estimated at 4.9 mSv and 0.86 mSv, respectively. Although the mean values and dispersion of external effective doses differed depending on the level of evacuation, for 93.3% of all residents, the estimated annual additional external effective doses were less than 2 mSv. Measuring air dose rates inside houses was found to be important to obtain a realistic evaluation of the external exposure dose because our research revealed that the average time spent indoors was 87% of the total living time. Moreover, the average exposure dose at home accounted for 66.8% of the annual exposure dose.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Time dependent verification techniques and dose- rate evaluation of external beam treatments
    Podesta, M.
    Persoon, L.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S143 - S143
  • [22] Computed Radiography Dose Measurements of External Radiotherapy Beams
    Aberle, C.
    Kapsch, R.
    MEDICAL PHYSICS, 2015, 42 (06) : 3383 - 3383
  • [23] ENVIRONMENTAL MEASUREMENTS OF EXTERNAL DOSE WITH A GM DETECTION SYSTEM
    WEDLICK, HL
    BROGA, DW
    HEALTH PHYSICS, 1975, 29 (06): : 904 - 904
  • [24] External gamma-ray dose rate and radon concentration in indoor environments covered with Brazilian granites
    Anjos, R. M.
    Juri Ayub, J.
    Cid, A. S.
    Cardoso, R.
    Lacerda, T.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2011, 102 (11) : 1055 - 1061
  • [25] Dose and Dose-rate Dependence of Polyethylene Irradiation with Electron Beams “in Air”
    L. Torrisi
    A.M. Visco
    N. Campo
    Journal of Materials Engineering and Performance, 2007, 16 : 97 - 101
  • [26] Dose and dose-rate dependence of polyethylene irradiation with electron beams "in air"
    Torrisi, L.
    Visco, A. M.
    Campo, N.
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2007, 16 (01) : 97 - 101
  • [27] Efficient dose-rate correction of silicon diode relative dose measurements
    Duchaine, Jasmine
    Markel, Daniel
    Bouchard, Hugo
    MEDICAL PHYSICS, 2022, 49 (06) : 4056 - 4070
  • [28] Dose and dose rate measurements in proton beams using the luminescence of beryllium oxide
    Teichmann, T.
    Torres, M. J. Gonzalez
    van Goethem, M. J.
    van der Graaf, E. R.
    Henniger, J.
    Jahn, A.
    Kiewiet, H. H.
    Sommer, M.
    Ullrich, W.
    Weinhold, C.
    Kormoll, T.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [29] Dose definition and physical dose evaluation for the human body in external radiation accidents
    Guo, Y
    Zhu, YP
    Zhang, J
    Ji, G
    Wu, K
    RADIATION PROTECTION DOSIMETRY, 1998, 77 (1-2) : 97 - 100
  • [30] A DOSE-REDUCING FLUOROSCOPY SYSTEM - DOSE MEASUREMENTS AND CLINICAL EVALUATION
    DORPH, S
    MYGIND, T
    NORTHEVED, A
    OKHOLM, B
    PETERSEN, KO
    OIGAARD, A
    RADIOLOGY, 1970, 97 (02) : 399 - +