External dose evaluation based on detailed air dose rate measurements in living environments

被引:12
|
作者
Sato, Tetsuro [1 ]
Andoh, Masaki [2 ]
Sato, Masako [3 ]
Saito, Kimiaki [2 ]
机构
[1] Hitachi Solut East Japan Lai, Aoba Ku, Metlife Sendai Honcho Bldg,2-16-10 Honcho, Sendai, Miyagi 9800014, Japan
[2] Japan Atom Energy Agcy, 11601-13 Nishi Jusanbugyo, Hitachinaka, Ibaraki 3191206, Japan
[3] Tokyo Records Management Co Inc, BR Gotanda, 2-30-4 Nishi Gotanda, Shinagawa, Tokyo 1410031, Japan
关键词
External dose; Returning residents; Evacuation order; Interview of life pattern; KURAMA-II; Fukushima dai-ichi nuclear power plant accident; Air dose; CONVERSION COEFFICIENTS;
D O I
10.1016/j.jenvrad.2019.05.005
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A method was devised to estimate the realistic external doses of residents expected to return to their homes after evacuation orders are lifted. For 196 residents expected to return to six towns and villages, surveys were administered in FY 2014-2016. After interviewing residents about their expected life patterns after their return, detailed air dose rate measurements were taken along their reported personal routes representing patterns of movement in their daily life. The maximum and average annual additional external effective dose were estimated at 4.9 mSv and 0.86 mSv, respectively. Although the mean values and dispersion of external effective doses differed depending on the level of evacuation, for 93.3% of all residents, the estimated annual additional external effective doses were less than 2 mSv. Measuring air dose rates inside houses was found to be important to obtain a realistic evaluation of the external exposure dose because our research revealed that the average time spent indoors was 87% of the total living time. Moreover, the average exposure dose at home accounted for 66.8% of the annual exposure dose.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] External dose-rate measurements based on smartphone CMOS sensors
    Mafodda, Alessia
    Woda, Clemens
    RADIATION MEASUREMENTS, 2020, 137
  • [2] Radon concentration in air and external gamma dose rate: is there a correlation?
    Yoshimura, Elisabeth M.
    Rodrigues Da Silva, Almy A.
    dos Anjos, Roberto M.
    Umisedo, Nancy K.
    Rizzotto, Marcos
    Velasco, Hugo
    Valladares, Diego L.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 307 (01) : 787 - 792
  • [3] Radon concentration in air and external gamma dose rate: is there a correlation?
    Elisabeth M. Yoshimura
    Almy A. Rodrigues Da Silva
    Roberto M. dos Anjos
    Nancy K. Umisedo
    Marcos Rizzotto
    Hugo Velasco
    Diego L. Valladares
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 307 : 787 - 792
  • [4] A SIMPLE CIRCUIT FOR SIMULTANEOUS DOSE-RATE AND DOSE MEASUREMENTS
    BENNER, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1959, 4 (01): : 28 - 29
  • [5] DETAILED MEASUREMENTS OF ELECTRON DOSE DISTRIBUTIONS IN RADIATION PROCESSING
    OPROIU, C
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (08): : 1057 - 1057
  • [7] Proton dose calculation based on in-air fluence measurements
    Schaffner, Barbara
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (06): : 1545 - 1562
  • [8] IN VIVO TLD DOSE MEASUREMENTS IN CATHETER-BASED HIGH-DOSE-RATE BRACHYTHERAPY
    Adliene, Diana
    Jakstas, Karolis
    Urbonavicius, Benas Gabrielis
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 477 - 481
  • [9] EFFECT OF AIR-SCATTERED RADIATION ON EXPOSURE DOSE-RATE MEASUREMENTS
    DOD, II
    YUDIN, MF
    MEASUREMENT TECHNIQUES, 1977, 20 (10) : 1502 - 1504
  • [10] Individualised dosimetry in patients with differentiated thyroid cancer based on external dose-rate. Optimisation of the number of measurements
    Bautista-Ballesteros, J. A.
    Torres-Espallardo, I.
    Borrelli, P.
    Rivas-Sanchez, A.
    Bello, P.
    Marti-Bonmati, L.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2016, 35 (02): : 107 - 114