Control of lateral balance in walking - Experimental findings in normal subjects and above-knee amputees

被引:366
|
作者
Hof, At L.
van Bockel, Renske M.
Schoppen, Tanneke
Postema, Klaas
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Ctr Rehabil, NL-9700 AD Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Ctr Human Movement Sci, NL-9700 AD Groningen, Netherlands
关键词
inverted pendulum model; stepping strategy; ankle strategy; equilibrium; gait;
D O I
10.1016/j.gaitpost.2006.04.013
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In walking the human body is never in balance. Most of the time the trunk is supported by one leg and the centre of mass (CoM) 'falls' to the contralateral side. In dynamical situations the velocity of the CoM should be acknowledged as well in the 'extrapolated centre of mass (XcoM). Centre of pressure (CoP) position was recorded by a treadmill with built-in force transducers. Lateral CoM and XcoM position were computed by filtering the CoP data. Subjects were six above-knee amputees and six matched healthy controls. They walked at approximately 0.75, 1, and 1.25 m/s for 2 min. Amputees showed asymmetric gait with shorter stance (60%) at the prosthetic side versus 68% at the non-prosthetic side and a wider stride (13 +/- 4 cm, mean S.D.) compared to controls (9 +/- 3 cm). At foot placement Col? was just lateral to the XcoM. The margin between average CoP and XcoM at foot contact was only 1.6 +/- 0.7 cm in controls, 2.7 +/- 0.5 cm in amputees at the prosthetic side and 1.9 +/- 0.6 cm at the non-prosthetic side. Next to this 'stepping strategy', Col? position was corrected after initial contact by modulating the lateral foot roll-off ('lateral ankle strategy') in non-prosthetic legs up to about 2 cm. A simple mechanical model, the inverted pendulum model, can explain that: (1) a less precise foot placement (greater CoP-XcoM margin) results in a wider stride, (2) this effect can be reduced by walking with a higher cadence, and (3) a greater margin at one side, as with a leg prosthesis, should be compensated by a shorter stance duration at the same side to achieve a straight path. This suggests that not in all cases symmetric gait should be an aim of rehabilitation. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:250 / 258
页数:9
相关论文
共 50 条
  • [21] A Prosthetic Knee Using Magnetorhelogical Fluid Damper for Above-Knee Amputees
    Park, Jinhyuk
    Choi, Seung-Bok
    ACTIVE AND PASSIVE SMART STRUCTURES AND INTEGRATED SYSTEMS 2015, 2015, 9431
  • [22] STUDIES OF MUSCLE STRENGTH AND PROSTHETIC ATTACHMENT IN ABOVE-KNEE AMPUTEES
    JAMES, U
    ACTA ORTHOPAEDICA SCANDINAVICA, 1974, 45 (06): : 973 - 973
  • [23] MULTIFUNCTIONAL ABOVE-KNEE PROSTHESIS FOR STAIRS WALKING
    KOGANEZAWA, K
    FUJIMOTO, H
    KATO, I
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1987, 11 (03) : 139 - 145
  • [24] NEW APPROACH TO ABOVE-KNEE LEG PROSTHETICS FOR ELDERLY AMPUTEES
    SELIKTAR, R
    SUSAK, Z
    NAJENSON, T
    ISRAEL JOURNAL OF TECHNOLOGY, 1975, 13 (03): : 218 - 224
  • [25] Computer simulation for the prediction of stump loading in above-knee amputees
    Ishai, G.
    Bar, A.
    1600, (21):
  • [26] IMPROVED ANKLE-FOOT SYSTEM FOR ABOVE-KNEE AMPUTEES
    JAMES, KB
    STEIN, RB
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1986, 65 (06) : 301 - 314
  • [27] END RESULTS IN SUCTION SOCKET PROSTHESIS FOR ABOVE-KNEE AMPUTEES
    THORNDIKE, A
    AMERICAN JOURNAL OF SURGERY, 1955, 89 (04): : 919 - 923
  • [28] THE LATERAL APPROACH TO THE ABOVE-KNEE FEMOROPOPLITEAL BYPASS
    KOFSKY, PM
    CARROLL, SF
    MORRIS, MC
    SURGERY GYNECOLOGY & OBSTETRICS, 1988, 166 (01): : 67 - 68
  • [29] Identification of the critical level of implantation of an osseointegrated prosthesis for above-knee amputees
    Castro, Elder Michael Andrango
    Konvickova, Svatava
    Daniel, Matej
    Horak, Zdenek
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 (14) : 1494 - 1501
  • [30] ExoProsthetics: Assisting Above-Knee Amputees with a Lightweight Powered Hip Exoskeleton
    Ishmael, Marshall K.
    Minh Tran
    Lenzi, Tommaso
    2019 IEEE 16TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR), 2019, : 925 - 930