Comparison of a MLC calibration method using a diode array and electronic portal imaging device

被引:0
|
作者
Simon, T.
Fox, C.
Li, J.
Palta, I.
Simon, W.
Liu, C.
机构
[1] Univ Florida, Gainesville, FL USA
[2] Sun Nucl Corp, Melbourne, FL USA
关键词
D O I
10.1118/1.2760373
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Current methods of MLC calibration and quality assurance include the use of graph paper, scanning water tanks, ion chambers, film and EPIDs; these methods can be both laborious and/or non‐quantitative. We propose a convenient and quantitative method for calibrating and performing routine quality assurance for MLCs. Method and Materials: The Profiler 2 (Sun Nuclear Corp., Melbourne, FL), a two dimensional diode array, was visually aligned to the backup jaw and irradiated with an Elekta linac. The backup jaw served as a radiation reference line and was used to determine the positional diode offsets. The MLC was stepped over the Profiler 2 and the 50% position for each diode was determined. Leaf offsets were calculated by offsetting each diodes 50% position by the 50% position of the diode corresponding to leaf pair 20 and subtracting the corresponding positional diode offset. This method was repeated with an EPID for comparison purposes. Results: Linear dose changes of approximately 15%/mm and 13.5%/mm were observed in the penumbras of the backup jaw and MLC, respectively. Leaf positions measured by the EPID and Profiler 2 differed on average by ± 0.12 mm per leaf. Leaf reproducibility of 0.36 mm or better was observed and minimal reproducibility changes were seen with the backup jaw. Conclusion: This work demonstrates the potential of the Profiler 2 as a tool for calibrating and performing quantitative QA for MLC leaf positioning. The Profiler 2 methods are fast, taking an average of 20 minutes to perform and accurately represent leaf positions and reproducibility. Conflict of Interest: This work was supported in part by SBIR Contract No. HHSN261200522014C, ADB Contract No. N43‐CM‐52214, the University of Florida and Sun Nuclear Corporation. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2337 / 2337
页数:1
相关论文
共 50 条
  • [41] Improvement of radiotherapy treatment delivery accuracy using an electronic portal imaging device
    Dirkx, M. L. P.
    de Boer, J. C. J.
    Heijmen, B. J. M.
    RADIATION PROTECTION DOSIMETRY, 2006, 121 (01) : 70 - 79
  • [42] Quality assurance of electron beams using a Varian electronic portal imaging device
    Wang, Y.
    Heaton, R.
    Norrlinger, B.
    Islam, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (16): : 5461 - 5475
  • [43] Using an electronic portal imaging device (EPID) for routine geometrical LINAC verifications
    Bejarano, M. Benito
    Beltran, F. Saez
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S253 - S254
  • [44] Verification of multileaf collimator leaf positions using an electronic portal imaging device
    Samant, SS
    Zheng, W
    Parra, NA
    Chandler, J
    Gopal, A
    Wu, J
    Jain, J
    Zhu, YP
    Sontag, M
    MEDICAL PHYSICS, 2002, 29 (12) : 2900 - 2912
  • [45] Validation of Gated RapidArc treatments delivery using the Electronic Portal Imaging Device
    Molinier, J.
    Bedos, L.
    Ailleres, N.
    Azria, D.
    Fenoglietto, P.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S158 - S158
  • [46] SIFT: A method to verify the IMRT fluence delivered during patient treatment using an electronic portal imaging device
    Vieira, SC
    Dirkx, MLP
    Heijmen, BJM
    de Boer, HCJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03): : 981 - 993
  • [47] Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device
    McCurdy, BMC
    Luchka, K
    Pistorius, S
    MEDICAL PHYSICS, 2001, 28 (06) : 911 - 924
  • [48] Portal dose measurements with a video-based electronic portal imaging device using a deconvolution algorithm
    Pasma, KL
    Kroonwijk, M
    Visser, AG
    Heijmen, BJM
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 282 - 284
  • [49] Physical characteristics of a commercial electronic portal imaging device
    Althof, VGM
    deBoer, JCJ
    Huizenga, H
    Stroom, JC
    Visser, AG
    Swanenburg, BN
    MEDICAL PHYSICS, 1996, 23 (11) : 1845 - 1855
  • [50] Analytical model of electronic portal imaging device response
    Harris, E
    Evans, P
    Seco, J
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S199 - S199