Low-dose dental computed tomography:: Significant dose reduction without loss of image quality

被引:43
|
作者
Rustemeyer, P
Streubühr, U
Suttmoeller, J
机构
[1] Univ Munster, Inst Anat, D-48149 Munster, Germany
[2] Univ Essen Gesamthsch, Dept Radiol, Essen, Germany
[3] Inspect Stn Radiat Protect, Wenningsen, Germany
关键词
Alderson-Rando-Phantom; dental CT; dose reduction; radiation protection;
D O I
10.1080/02841850410001402
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To measure and reduce the patient dose during computed tomography (CT) for dental applications. Material and Methods: Lithium fluoride thermoluminescent dosimeters were implanted in a tissue-equivalent humanoid phantom (Alderson-Rando-Phantom) to determine doses to the thyroid gland, the active bone marrow, the salivary glands, and the eye lens. Dental CT was performed with spiral CT and a dental software package. The usual dental CT technique was compared with a new dose-reduced protocol, which delivered best image quality at lowest possible radiation dose, as tested in a preceding study. Image quality was analysed using a human anatomic head preparation. In addition, the radiation dose was compared with panoramic radiography and digital volume tomography (DVT). Eight radiologists evaluated all images in a blinded fashion. A Wilcoxon rank pair test was used for statistical evaluation. Results: Radiation dose could be reduced by a factor of 9 (max.) with the new dose-reduced protocol (e.g. bone marrow dose from 23.6 mSv to 2.9 mSv; eye lens from 0.5 mSv to 0.3 mSv; thyroid gland from 2.5 mSv to 0.5 mSv; parotid glands from 2.3 mSv to 0.4 mSv). Dose reduction did not reduce image quality or diagnostic information. Conclusion: A considerable dose reduction without loss of diagnostic information is achievable in dental CT. As radiation exposure of the presented low-dose protocol is expected to be in the same range as DVT, low-dose dental CT might be superior to DVT, because CT can be used to evaluate soft tissues as well.
引用
收藏
页码:847 / 853
页数:7
相关论文
共 50 条
  • [1] Low-dose abdominopelvic computed tomography in patients with lymphoma: An image quality and radiation dose reduction study
    Yoon, Sungjin
    Yoo, Kwai Han
    Park, So Hyun
    Kim, Hawk
    Lee, Jae Hoon
    Park, Jinny
    Park, Seong Ho
    Kim, Hwa Jung
    [J]. PLOS ONE, 2022, 17 (08):
  • [2] Low-dose computed tomography perceptual image quality assessment
    Lee, Wonkyeong
    Wagner, Fabian
    Galdran, Adrian
    Shi, Yongyi
    Xia, Wenjun
    Wang, Ge
    Mou, Xuanqin
    Ahamed, Md. Atik
    Imran, Abdullah Al Zubaer
    Oh, Ji Eun
    Kim, Kyungsang
    Baek, Jong Tak
    Lee, Dongheon
    Hong, Boohwi
    Tempelman, Philip
    Lyu, Donghang
    Kuiper, Adrian
    van Blokland, Lars
    Calisto, Maria Baldeon
    Hsieh, Scott
    Han, Minah
    Baek, Jongduk
    Maier, Andreas
    Wang, Adam
    Gold, Garry Evan
    Choi, Jang-Hwan
    [J]. Medical Image Analysis, 2025, 99
  • [3] Image Fusion for Low-Dose Computed Tomography Reconstruction
    Ma, Jianhua
    Huang, Jing
    Liang, Zhengrong
    Zhang, Hua
    Fan, Yi
    Feng, Qianjin
    Chen, Wufan
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4239 - 4243
  • [4] Usefulness of Ag Additional Filter on Image Quality and Radiation Dose for Low-Dose Chest Computed Tomography
    Kawamoto, Keishin
    Sato, Hideyuki
    Kogure, Yosuke
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (02) : 236 - 243
  • [5] A multi-institutional assessment of low-dose protocols in chest computed tomography: Dose and image quality
    Tonkopi, Elena
    Tetteh, Mercy Afadzi
    Gunn, Catherine
    Ashraf, Haseem
    Rusten, Sigrid Lia
    Safi, Perkhah
    Tinsoe, Nora Suu
    Colford, Kylie
    Ouellet, Olivia
    Naimi, Salma
    Johansen, Safora
    [J]. ACTA RADIOLOGICA OPEN, 2024, 13 (01)
  • [6] Adaptive noise reduction toward low-dose computed tomography
    Lu, HB
    Li, X
    Li, LH
    Chen, DQ
    Xing, YX
    Hsieh, J
    Liang, ZR
    [J]. MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 759 - 766
  • [7] Adaptive Image Denoising Approach for Low-Dose Computed Tomography
    Elyamani, Haneen A.
    El-Seoud, Samir A.
    Kudo, Hiroyuki
    Rashed, Essam A.
    [J]. 2017 12TH INTERNATIONAL CONFERENCE ON COMPUTER ENGINEERING AND SYSTEMS (ICCES), 2017, : 66 - 72
  • [8] A study to improve the image quality in low-dose computed tomography (SPECT) using filtration
    Kheruka, S. C.
    Naithani, U. C.
    Maurya, A. K.
    Painuly, N. K.
    Aggarwal, L. M.
    Gambhir, S.
    [J]. INDIAN JOURNAL OF NUCLEAR MEDICINE, 2011, 26 (01): : 14 - 21
  • [9] LOW-DOSE COMPUTED-TOMOGRAPHY
    GHOLKAR, A
    HART, CW
    MOTT, D
    GILLESPIE, JE
    ISHERWOOD, I
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (728): : 773 - 773
  • [10] Image quality and dose in computed tomography
    Jurik, AG
    Jessen, KA
    Hansen, J
    [J]. EUROPEAN RADIOLOGY, 1997, 7 (01) : 77 - 81