Electrochemical Resistive DNA Biosensor for the Detection of HPV Type 16

被引:21
|
作者
Espinosa, Jose R. [1 ,2 ]
Galvan, Marisol [3 ]
Quinones, Arturo S. [3 ]
Ayala, Jorge L. [3 ]
Avila, Veronica [4 ]
Duron, Sergio M. [3 ]
机构
[1] Univ Autonoma Zacatecas, Unidad Acad Ingn Elect, Av Ramon Lopez Velarde 801, Zacatecas 98000, Zacatecas, Mexico
[2] Univ Autonoma Zacatecas, Ingn Mecan, Unidad Acad Ingn 1, Av Ramon Lopez Velarde 801, Zacatecas 98000, Zacatecas, Mexico
[3] Univ Autonoma Zacatecas, Unidad Acad Ciencias Quim, Campus Siglo XXI,Edif 6, Zacatecas 98160, Zacatecas, Mexico
[4] Inst Politecn Nacl, Unidad Profes Interdisciplinaria Ingn, Ingn Ambiental, Campus Zacatecas, Zacatecas 98160, Zacatecas, Mexico
来源
MOLECULES | 2021年 / 26卷 / 11期
关键词
current relaxation; electrochemical HPV-16 DNA biosensor; potential relaxation; faradaic current; PEPTIDE NUCLEIC-ACID; HUMAN-PAPILLOMAVIRUS; DESIGN; PREVALENCE; SENSORS; PROTEIN;
D O I
10.3390/molecules26113436
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this work, a low-cost and rapid electrochemical resistive DNA biosensor based on the current relaxation method is described. A DNA probe, complementary to the specific human papillomavirus type 16 (HPV-16) sequence, was immobilized onto a screen-printed gold electrode. DNA hybridization was detected by applying a potential step of 30 mV to the system, composed of an external capacitor and the modified electrode DNA/gold, for 750 mu s and then relaxed back to the OCP, at which point the voltage and current discharging curves are registered for 25 ms. From the discharging curves, the potential and current relaxation were evaluated, and by using Ohm's law, the charge transfer resistance through the DNA-modified electrode was calculated. The presence of a complementary sequence was detected by the change in resistance when the ssDNA is transformed in dsDNA due to the hybridization event. The target DNA concentration was detected in the range of 5 to 20 nM. The results showed a good fit to the regression equation Delta R-total(Omega) = 2.99 x [DNA] + 81.55, and a detection limit of 2.39 nM was obtained. As the sensing approach uses a direct current, the electronic architecture of the biosensor is simple and allows for the separation of faradic and nonfaradaic contributions. The simple electrochemical resistive biosensor reported here is a good candidate for the point-of-care diagnosis of HPV at a low cost and in a short detection time.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Simple electrochemical DNA biosensor for detection of DNA damage induced by hydroxyl radicals
    Hajkova, Andrea
    Vyskocil, Vlastimil
    Barek, Jiri
    PROCEEDINGS OF THE 11TH INTERNATIONAL STUDENTS CONFERENCE "MODERN ANALYTICAL CHEMISTRY", 2015, : 19 - 22
  • [32] An electrochemical DNA biosensor for the detection of DNA damage caused by radioactive iodine and technetium
    Kara, Pinar
    Dagdeviren, Kagan
    Oezsoez, Mehmet
    TURKISH JOURNAL OF CHEMISTRY, 2007, 31 (03) : 243 - 249
  • [33] Carbon nanotube-enhanced electrochemical DNA biosensor for DNA hybridization detection
    Cai, H
    Cao, XN
    Jiang, Y
    He, PG
    Fang, YZ
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (02) : 287 - 293
  • [34] Carbon nanotube-enhanced electrochemical DNA biosensor for DNA hybridization detection
    Hong Cai
    Xuni Cao
    Ying Jiang
    Pingang He
    Yuzhi Fang
    Analytical and Bioanalytical Chemistry, 2003, 375 : 287 - 293
  • [35] Detection of the damage caused to DNA by niclosamide using an electrochemical DNA-biosensor
    Abreu, FC
    Goulart, MOF
    Brett, AMO
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12): : 913 - 919
  • [36] Detection of DNA Damage Induced by Hydroquinone and Catechol Using an Electrochemical DNA Biosensor
    Wang, Chuanhu
    Zhao, Jun
    Zhang, Dapeng
    Yang, Zhousheng
    AUSTRALIAN JOURNAL OF CHEMISTRY, 2009, 62 (09) : 1181 - 1184
  • [37] Ultrasensitive detection of HIV DNA using an electrochemical biosensor with branched DNA amplification
    Ma, Mingyi
    He, Li
    Shi, Xiaoxue
    Wang, Yanchao
    Hai, Hong
    Wei, Xiaoping
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2023, 18 (10):
  • [38] DETECTION OF HPV-16 BY DNA DOT BLOT HYBRIDIZATION
    HALLAM, NF
    GIBSON, PE
    LANCET, 1987, 2 (8554): : 335 - 335
  • [39] Development of a lateral flow strip biosensor based on copper oxide nanoparticles for rapid and sensitive detection of HPV16 DNA
    Yang, Zheng
    Yi, Chun
    Lv, Sijia
    Sheng, Yuhao
    Wen, Wei
    Zhang, Xiuhua
    Wang, Shengfu
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 285 : 326 - 332
  • [40] DNA electrochemical biosensor for the detection of short DNA sequences related to the hepatitis B virus
    Erdem, A
    Kerman, K
    Meric, B
    Akarca, US
    Ozsoz, M
    ELECTROANALYSIS, 1999, 11 (08) : 586 - 588