Assessment of glucose kinetics with real-time continuous glucose monitoring during labor

被引:0
|
作者
Maki, Jota [1 ]
Eto, Eriko [1 ]
Tamada, Shoko [1 ]
Mitsui, Takashi [1 ]
Hayata, Kei [1 ]
Nakamura, Keiichiro [1 ]
Hiramatsu, Yuji [2 ]
Masuyama, Hisashi [1 ]
机构
[1] Okayama Univ, Dept Obstet & Gynecol, Grad Sch Med Dent & Pharmaceut Sci, Okayama, Japan
[2] Okayama City Gen Med Ctr, Okayama, Japan
基金
日本学术振兴会;
关键词
continuous glucose monitoring; during labor; gestational diabetes mellitus; glucose level; pregnancy; GESTATIONAL DIABETES-MELLITUS; JAPAN JAPAN SOCIETY; OBSTETRICAL PRACTICE; GYNECOLOGY [!text type='JS']JS[!/text]OG; BLOOD-GLUCOSE; INSULIN-PUMP; TYPE-1; ASSOCIATION; PREGNANCY; GUIDELINES;
D O I
10.1111/jog.14058
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aim Changes in glucose levels during labor have not been sufficiently investigated in pregnant women. Using real-time continuous glucose monitoring, we aimed to assess glucose kinetics during labor among pregnant women with gestational diabetes mellitus (PwGDM), and those with normal glucose tolerance (PwNGT). Methods Japanese PwGDM and PwNGT who had planned a transvaginal delivery at Okayama University Hospital were enrolled. The correlation between changes in glucose levels during labor among the PwGDM and PwNGT groups at four time periods was assessed: (i) active phase of 1st stage of labor; (ii) 2nd stage of labor; (iii) postpartum 0-12 h; and (iv) postpartum 12-48 h. Results In total, 18 and 22 PwGDM and PwNGT, respectively, were enrolled. During labor, both groups had similar changes in glucose levels over time, which peaked during period 3. The main effect of glucose level changes was the labor period (P < 0.001), not the presence of gestational diabetes mellitus. Furthermore, differences in glucose levels in the PwGDM group were observed between periods 1 and 2 (P = 0.037), 1 and 3 (P = 0.024), 3 and 4 (P = 0.005); differences in glucose levels in the PwNGT group were observed between periods 3 and 4 (P = 0.024). Conclusion During labor, both PwGDM and PwNGT groups showed similar changes in glucose levels over time. During delivery, the PwGDM who regularly measured their own glucose levels could be managed using the same nutritional management methods as those for PwNGT.
引用
收藏
页码:1851 / 1859
页数:9
相关论文
共 50 条
  • [1] Real-time continuous glucose monitoring in the ICU
    J Gios
    B Manuel-y-Keenoy
    P Rogiers
    [J]. Critical Care, 19 (Suppl 1):
  • [2] A real-time continuous glucose monitoring for diabetic women during the delivery
    Ghio, A.
    Lencioni, C.
    Romero, F.
    Pancani, F.
    Bertolotto, A.
    Aragona, M.
    Del Prato, S.
    Volpe, L.
    Di Cianni, G.
    [J]. DIABETOLOGIA, 2009, 52 : S462 - S462
  • [3] Accuracy of real-time glucose values using continuous glucose monitoring:: the Guardian™ II continuous glucose monitoring system
    Schwartz, SL
    Buchea, O
    Shin, J
    Hoss, U
    Shah, R
    [J]. DIABETOLOGIA, 2004, 47 : A315 - A315
  • [4] Practical Aspects of Real-Time Continuous Glucose Monitoring
    Gilliam, Lisa K.
    Hirsch, Irl B.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 : S75 - S82
  • [5] Real-Time Continuous Glucose Monitoring in Preterm Infants
    Joseph, Rachel
    Rosa, Jenna Hope-Altomari
    [J]. NEONATAL NETWORK, 2022, 41 (06): : 376 - 376
  • [6] Reliability of real-time continuous glucose monitoring in infants
    Tomotaki, Seiichi
    Toyoshima, Katsuaki
    Shimokaze, Tomoyuki
    Kawai, Masahiko
    [J]. PEDIATRICS INTERNATIONAL, 2019, 61 (10) : 1001 - 1006
  • [7] Real-Time Improvement of Continuous Glucose Monitoring Accuracy
    Facchinetti, Andrea
    Sparacino, Giovanni
    Guerra, Stefania
    Luijf, Yoeri M.
    DeVries, J. Hans
    Mader, Julia K.
    Ellmerer, Martin
    Benesch, Carsten
    Heinemann, Lutz
    Bruttomesso, Daniela
    Avogaro, Angelo
    Cobelli, Claudio
    [J]. DIABETES CARE, 2013, 36 (04) : 793 - 800
  • [8] Benefits of Real-Time Continuous Glucose Monitoring in Pregnancy
    Yamamoto, Jennifer M.
    Murphy, Helen R.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : S8 - S14
  • [9] Clinical Use of Real-Time Continuous Glucose Monitoring
    Battelino, Tadej
    Bolinder, Jan
    [J]. CURRENT DIABETES REVIEWS, 2008, 4 (03) : 218 - 222
  • [10] Interstitial fluid glucose time-lag correction for real-time continuous glucose monitoring
    Keenan, D. Barry
    Mastrototaro, John J.
    Weinzimer, Stuart A.
    Steil, Garry M.
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2013, 8 (01) : 81 - 89