Large Basilar Apex Aneurysms Treated with Flow-Diverter Stents

被引:14
|
作者
Da Ros, V. [1 ,2 ]
Caroff, J. [2 ]
Rouchaud, A. [2 ]
Mihalea, C. [2 ,3 ]
Ikka, L. [2 ]
Moret, J. [2 ]
Spelle, L. [2 ,4 ]
机构
[1] Policlin Tor Vergata, Dept Diagnost Imaging & Intervent Radiol Mol Imag, Rome, Italy
[2] Hop Bicetre, Intervent Neuroradiol NEURI Ctr, 78 Rue Gen Leclerc, F-94270 Le Kremlin Bicetre, France
[3] Univ Med & Farm Timisoara, Dept Neurosurg, Timisoara, Romania
[4] Univ Paris Sud XI, Le Kremlin Bicetre, France
关键词
PIPELINE EMBOLIZATION DEVICE; POSTERIOR COMMUNICATING ARTERY; INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT; CEREBRAL ANEURYSMS; PERFORATING BRANCHES; CIRCULATORY ARREST; TIP ANEURYSMS; SILK STENT; RECONSTRUCTION;
D O I
10.3174/ajnr.A5167
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The authors report their experience treating basilar apex aneurysms with flow-diverter stents and evaluate their efficacy and safety profile in this specific condition. Of the 175 aneurysms treated with flow-diverter stents at their institution, 5 patients received flow-diverter stents for basilar apex aneurysms. The mean follow-up after stent deployment was 21 months. They conclude that flow diversion is a feasible technique with an efficacy demonstrated at a midterm follow-up, especially in the case of basilar apex aneurysm recurrences after previous endovascular treatments. BACKGROUND AND PURPOSE: The treatment of wide-neck, large basilar apex aneurysms is challenging with either an endovascular or a surgical approach. The aim of the present study was to report our experience treating basilar apex aneurysms with flow-diverter stents and to evaluate their efficacy and safety profile in this specific anatomic condition. MATERIALS AND METHODS: We retrospectively analyzed data from all consecutive patients treated with flow-diverter stents at our institution between January 2011 and January 2015. Patients with large basilar apex aneurysms treated with a flow-diverter stent were included in the study. Clinical presentations, technical details, intra- and perioperative complications, and clinical and angiographic outcomes were recorded, with a midterm follow-up. RESULTS: Of the 175 aneurysms treated with flow-diverter stents at our institution, 5 patients (2 women and 3 men; age range, 44-58 years) received flow-diverter stent for basilar apex aneurysms. The mean follow-up after stent deployment was 21 months (range, 15-24 months). One patient died on day 31 from an early postprocedural midbrain hemorrhage. One patient had a right cerebellar hemispheric ischemic lesion with a transient cerebellar syndrome resolved within 24 hours without neurologic sequelae at the latest follow-up. The mRS was 0 in 4 patients and 6 in 1 patient at last follow-up. CONCLUSIONS: Flow diversion is a feasible technique with an efficacy demonstrated at a midterm follow-up, especially in the case of basilar apex aneurysm recurrences after previous endovascular treatments. Concern about its safety profile still exists.
引用
下载
收藏
页码:1156 / 1162
页数:7
相关论文
共 50 条
  • [31] Utility of VasoCT in the treatment of intracranial aneurysm with flow-diverter stents Clinical article
    Kizilkilic, Osman
    Kocer, Naci
    Metaxas, George Emmanuel
    Babic, Drazenko
    Homan, Robert
    Islak, Civan
    JOURNAL OF NEUROSURGERY, 2012, 117 (01) : 45 - 49
  • [32] Virtual Reality Visualization of CFD Simulated Blood Flow in Cerebral Aneurysms Treated with Flow Diverter Stents
    Islami, Sima Baheri
    Wesolowski, Mike
    Revell, William
    Chen, Xiongbiao
    APPLIED SCIENCES-BASEL, 2021, 11 (17):
  • [33] Hydrodynamic Resistance of Intracranial Flow-Diverter Stents: Measurement Description and Data Evaluation
    Csippa, Benjamin
    Gyurki, Daniel
    Zavodszky, Gabor
    Szikora, Istvan
    Paal, Gyorgy
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2020, 11 (01) : 1 - 13
  • [34] Endovascular treatment of cerebral aneurysms using flow-diverter devices: A systematic review
    Briganti, Francesco
    Leone, Giuseppe
    Marseglia, Mariano
    Mariniello, Giuseppe
    Caranci, Ferdinando
    Brunetti, Arturo
    Maiuri, Francesco
    NEURORADIOLOGY JOURNAL, 2015, 28 (04): : 365 - 375
  • [35] Flow Diversion for the Treatment of Basilar Apex Aneurysms COMMENT
    Grossberg, Jonathan Andrew
    Brasiliense, Leonardo
    Dumont, Travis M.
    Alaraj, Ali
    NEUROSURGERY, 2018, 83 (06) : 1304 - 1305
  • [36] Retreatment strategies for recurrent and residual aneurysms after treatment with flow-diverter devices
    Goertz, Lukas
    Hesse, Nina
    Liebig, Thomas
    Ahmad, Wael
    Abdullayev, Nuran
    Krischek, Boris
    Kabbasch, Christoph
    Dorn, Franziska
    NEURORADIOLOGY, 2020, 62 (08) : 1019 - 1028
  • [37] Endovascular Treatment of Wide Necked Ruptured Saccular Aneurysms with Flow-Diverter Stent
    Duman, Enes
    Coven, Ilker
    Yildirim, Erkan
    Yilmaz, Cem
    Pinar, H. Ulas
    TURKISH NEUROSURGERY, 2017, 27 (03) : 362 - 367
  • [38] Retreatment strategies for recurrent and residual aneurysms after treatment with flow-diverter devices
    Lukas Goertz
    Nina Hesse
    Thomas Liebig
    Wael Ahmad
    Nuran Abdullayev
    Boris Krischek
    Christoph Kabbasch
    Franziska Dorn
    Neuroradiology, 2020, 62 : 1019 - 1028
  • [39] Clinical evaluation of high-resolution cone-beam computed tomography for the implantation of flow-diverter stents in intracranial aneurysms
    Yu, Sun
    Shi, Cheng-Cheng
    Ma, Ji
    Wang, Ye
    Zhu, Ming
    Ren, Jian-Zhuang
    Han, Xin-Wei
    Li, Teng-Fei
    Li, Teng-Fei
    JOURNAL OF CLINICAL NEUROSCIENCE, 2022, 103 : 14 - 19
  • [40] Endovascular Treatment of Large and Giant Carotid Aneurysms with Flow-Diverter Stents Alone or in Combination with Coils: A Multicenter Experience and Long-Term Follow-up
    Peschillo, Simone
    Caporlingua, Alessandro
    Resta, Maria Chiara
    Peluso, Jo Peter Paul
    Burdi, Nicola
    Sourour, Nader
    Diana, Francesco
    Guidetti, Giulio
    Clarencon, Frederic
    Bloemsma, Gijs Coenraad
    Di Maria, Federico
    Donatelli, Massimo
    Resta, Maurizio
    OPERATIVE NEUROSURGERY, 2017, 13 (04) : 492 - 502