Reproducibility of Retinal Nerve Fiber Layer and Macular Thickness Measurement with the RTVue-100 Optical Coherence Tomograph

被引:155
|
作者
Garas, Anita [1 ]
Vargha, Peter [2 ]
Hollo, Gabor [1 ]
机构
[1] Semmelweis Univ, Dept Ophthalmol, Budapest, Hungary
[2] Semmelweis Univ, Ctr Cardiovasc, Budapest, Hungary
关键词
STRATUS OCT; TIME-DOMAIN; SPECTRAL-DOMAIN; FOURIER-DOMAIN; GLAUCOMA; VARIABILITY; IMPROVES;
D O I
10.1016/j.ophtha.2009.08.039
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the reproducibility of peripapillary retinal nerve fiber layer thickness (RNFLT) and ganglion cell complex (GCC) measurements made with the RTVue-100 Fourier-domain optical coherence tomography (OCT) device (Optovue, Inc., Fremont, CA) and to determine the influence of 4 factors: pupil dilation, subject age, experience in imaging examinations, and glaucoma severity. Design: Prospective study for evaluation of a diagnostic test. Participants: Thirty-seven hospital-based participants (14 normal and ocular hypertensive subjects, 11 patients with moderate and 12 with severe glaucoma), all experienced in imaging examinations, and 40 consecutive screening trial participants lacking such experience. Methods: One eye of all participants was imaged 5 times. For the hospital-based participants, on the same day the measurement series was repeated after pupil dilation. For determination of intersession reproducibility, measurements were performed again 3 months later. Main Outcome Measures: Intrasession and intersession coefficient of variation (CV), intraclass correlation coefficient (ICC), intratest variability, and test-retest variability. Results: For the average and quadrant RNFLT parameters and the GCC parameters, intrasession ICC varied between 93.9% and 99.0%, intrasession CV between 1.95% and 5.69%, and intratest variability varied between 3.11 and 9.13 mu m. Most thickness values, all intrasession CV and intratest variability values, and the signal strength index were not changed significantly after pupil dilation. Intrasession CV of the 16 peripapillary RNFLT sectors varied between 4.90% and 11.66%. Most intrasession CV values increased significantly with increased disease severity, but intratest variability for average RNFLT and the quadrant RNFLT parameters, which are used for statistical comparison with the normative database, were unaffected by the severity of glaucoma. Patient age and experience in imaging examinations had no influence on intrasession CV. Intratest variability and intrasession CV represented 79.1% to 98.6% and 77.1% to 95.0% of test-retest variability and intervisit CV, respectively, for the average and quadrant RNFLT and the GCC parameters. Conclusions: Intrasession and intersession reproducibility of RNFLT and GCC measurements with the RTVue-100 OCT are satisfactory for diagnostic purposes, both in normals and in patients with different glaucoma severity. Pupil dilation, age, and experience in imaging examinations did not influence reproducibility in a clinically significant manner. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2010;117:738-746 (C) 2010 by the American Academy of Ophthalmology.
引用
收藏
页码:738 / 746
页数:9
相关论文
共 50 条
  • [1] Diagnostic accuracy of nerve fibre layer, macular thickness and optic disc measurements made with the RTVue-100 optical coherence tomograph to detect glaucoma
    A Garas
    P Vargha
    G Holló
    Eye, 2011, 25 : 57 - 65
  • [2] Diagnostic accuracy of nerve fibre layer, macular thickness and optic disc measurements made with the RTVue-100 optical coherence tomograph to detect glaucoma
    Garas, A.
    Vargha, P.
    Hollo, G.
    EYE, 2011, 25 (01) : 57 - 65
  • [3] Agreement and Repeatability of Different Disc-Definition Methods for Optic Nerve Head and Retinal Nerve Fiber Layer Measurements with the RTVue-100 Optical Coherence Tomograph
    Garas, A.
    Vargha, P.
    Hollo, G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [4] Automatic, Operator-adjusted, and Manual Disc-definition for Optic Nerve Head and Retinal Nerve Fiber Layer Measurements With the RTVue-100 Optical Coherence Tomograph
    Garas, Anita
    Vargha, Peter
    Hollo, Gabor
    JOURNAL OF GLAUCOMA, 2011, 20 (02) : 80 - 86
  • [5] Macular and retinal nerve fiber layer thickness measurement reproducibility using optical coherence tomography (OCT-3)
    Gürses-Özden, R
    Teng, C
    Vessani, R
    Zafar, S
    Liebmann, JM
    Ritch, R
    JOURNAL OF GLAUCOMA, 2004, 13 (03) : 238 - 244
  • [6] Macular and retinal nerve fiber layer thickness measurement reproducibility using optical coherence tomography (OCT-3)
    Teng, CC
    Gurses-Ozden, R
    Vessani, RM
    Makornwattana, M
    Rubin, B
    Zafar, S
    Liebmann, JM
    Tello, C
    Ritch, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U234 - U234
  • [7] Reproducibility of corneal, macular and retinal nerve fiber layer thickness measurements using the iVue-100 optical coherence tomography
    Mashige, Khathutshelo P.
    AFRICAN HEALTH SCIENCES, 2017, 17 (04) : 1222 - 1228
  • [8] Reproducibility of RTVue Retinal Nerve Fiber Layer Thickness and Optic Disc Measurements and Agreement with Stratus Optical Coherence Tomography Measurements
    Gonzalez-Garcia, Alberto O.
    Vizzeri, Gianmarco
    Bowd, Christopher
    Medeiros, Felipe A.
    Zangwill, Linda M.
    Weinreb, Robert N.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (06) : 1067 - 1074
  • [9] Reproducibility of Retinal Nerve Fiber Layer and Macular Thickness Measurements Using Spectral Domain Optical Coherence Tomography
    Sood, Amit
    Paliwal, Rahul Omprakash
    Mishra, Rishu Yogesh
    GALICIAN MEDICAL JOURNAL, 2021, 28 (04)
  • [10] Comparison of two retinal nerve fibre layer thickness measurement patterns of RTvue optical coherence tomography
    Li, Shuning
    Wang, Xiaozhen
    Wu, Gewei
    Fu, Jing
    Li, Songfeng
    Wan, Xiuhua
    Wang, Ningli
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (03): : 222 - 229