Continuous EEG source imaging enhances analysis of EEG-fMRI in focal epilepsy

被引:44
|
作者
Vulliemoz, S. [1 ,2 ,3 ]
Rodionov, R. [1 ,2 ]
Carmichael, D. W. [1 ,2 ]
Thornton, R. [1 ,2 ]
Guye, M. [4 ,5 ,6 ]
Lhatoo, S. D. [7 ]
Michel, C. M. [3 ]
Duncan, J. S. [1 ,2 ]
Lemieux, L. [1 ,2 ]
机构
[1] UCL Inst Neurol, Dept Clin & Expt Epilepsy, MRI Unit, Natl Soc Epilepsy, London WC1N 3BG, England
[2] Natl Hosp Neurol & Neurosurg, London WC1N 3BG, England
[3] Univ Geneva, CH-1211 Geneva 4, Switzerland
[4] Fac Med, CNRS, UMR 6612, Marseille, France
[5] INSERM, U751, Serv Neurophysiol Clin, F-13258 Marseille, France
[6] CHU Timone, Marseille, France
[7] Frenchay Hosp, Dept Neurol, N Bristol NHS Trust, Bristol BS16 1LE, Avon, England
基金
英国医学研究理事会; 瑞士国家科学基金会;
关键词
EEG; Source imaging; Epilepsy; Interictal; fMRI; INTERICTAL EPILEPTIFORM ACTIVITY; INDEPENDENT COMPONENT ANALYSIS; SOURCE LOCALIZATION; BOLD RESPONSES; INTRACRANIAL EEG; FUNCTIONAL MRI; DEFAULT MODE; SCALP EEG; SPIKES; ARTIFACT;
D O I
10.1016/j.neuroimage.2009.11.055
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Introduction: EEG-correlated fMRI (EEG-fMRI) Studies can reveal haemodynamic changes associated with Interictal Epileptic Discharges (IED). Methodological improvements are needed to increase sensitivity and specificity for localising the epileptogenic zone. We investigated whether the estimated EEG source activity improved models of the BOLD changes in EEG-fMRI data, compared to conventional a event-related D designs based solely on the visual identification of IED. Methods: Ten patients with pharmaco-resistant focal epilepsy underwent EEG-fMRI. EEG Source Imaging (ESI) was performed on intra-fMRI averaged IED to identify the irritative zone. The continuous activity of this estimated IED source (cESI) over the entire recording was used for fMRI analysis (cESI model). The maps of BOLD signal changes explained by cESI were compared to results of the conventional IED-related model. Results: ESI was concordant with non-invasive data in 13/15 different types of IED. The cESI model explained significant additional BOLD variance in regions concordant with video-EEG, structural MRI or, when available, intracranial EEG in 10/15 IED. The cESI model allowed better detection of the BOLD cluster, concordant with intracranial EEG in 4/7 IED, compared to the IED model. In 4 IED types, cESI-related BOLD signal changes were diffuse with a pattern suggestive of contamination of the source signal by artefacts, notably incompletely corrected motion and pulse artefact. In one IED type, there was no significant BOLD change with either model. Conclusion: Continuous EEG source imaging can improve the modelling of BOLD changes related to interictal epileptic activity and this may enhance the localisation of the irritative zone. (C) 2009 Elsevier Inc. All tights reserved.
引用
收藏
页码:3219 / 3229
页数:11
相关论文
共 50 条
  • [21] Joint EEG-fMRI model for EEG source separation
    Sun, Peng
    Hicks, Yulia
    Setchi, Rossitza
    2014 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS (SMC), 2014, : 2234 - 2239
  • [22] Different ways to analyze EEG-fMRI in focal epilepsy: Does it matter?
    van Houdt, Petra
    Zijlmans, Maeike
    CLINICAL NEUROPHYSIOLOGY, 2013, 124 (11) : 2070 - 2072
  • [23] The benefits of simultaneous EEG-fMRI for EEG analysis
    Debener, Stefan
    De Vos, Maarten
    CLINICAL NEUROPHYSIOLOGY, 2011, 122 (02) : 217 - 218
  • [24] Intracranial EEG-fMRI analysis of focal epileptiform discharges in humans
    Cunningham, Cameron B. J.
    Goodyear, Bradley G.
    Badawy, Radwa
    Zaamout, Fateh
    Pittman, Daniel J.
    Beers, Craig A.
    Federico, Paolo
    EPILEPSIA, 2012, 53 (09) : 1636 - 1648
  • [25] Ictal EEG-fMRI in localization of epileptogenic area in refractory neocortical focal epilepsy
    Sierra-Marcos, A.
    EUROPEAN JOURNAL OF NEUROLOGY, 2012, 19 : 844 - 844
  • [26] Multimodal Imaging with Simultaneous EEG-fMRI
    Marecek, R.
    Mikl, M.
    Rektor, I.
    Brazdil, M.
    CESKA A SLOVENSKA NEUROLOGIE A NEUROCHIRURGIE, 2012, 75 (01) : 18 - 22
  • [27] EEG-fMRI of epileptic spikes:: Concordance with EEG source localization and intracranial EEG
    Benar, Christian-G.
    Grova, Christophe
    Kobayashi, Eliane
    Bagshaw, Andrew P.
    Aghakhani, Yahya
    Dubeau, Fran Ois
    Gotman, Jean
    NEUROIMAGE, 2006, 30 (04) : 1161 - 1170
  • [28] COMPARISON OF EEG-FMRI DATA TO INVASIVE ELECTROPHYSIOLOGICAL REGISTRATION IN CRYPTOGENIC FOCAL EPILEPSY
    Pesaresi, I.
    Fabbri, S.
    Barba, C.
    Bartolini, E.
    Cecchi, P.
    Giordano, F.
    Quaglia, F. M.
    Pruna, D.
    Cosottini, M.
    Guerrini, R.
    EPILEPSIA, 2012, 53 : 56 - 56
  • [29] EEG-fMRI IN EPILEPSY: A CRITICAL VIEW ON METHODOLOGY
    Benar, C.
    EPILEPSIA, 2009, 50 : 35 - 35
  • [30] EEG-fMRI in atypical benign partial epilepsy
    Moeller, Friederike
    Moehring, Jan
    Ick, Imke
    Steinmann, Elisabeth
    Wolff, Stephan
    Jansen, Olav
    Boor, Rainer
    Stephani, Ulrich
    Siniatchkin, Michael
    EPILEPSIA, 2013, 54 (08) : E103 - E108