Evaluating computer-aided detection algorithms

被引:38
|
作者
Yoon, Hong Jun
Zheng, Bin
Sahiner, Berkman
Chakraborty, Dev P. [1 ]
机构
[1] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15261 USA
[2] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
CAD evaluation; free-response; FROC curves; lesion localization; search model; maximum likelihood; figure of merit; imaging system optimization;
D O I
10.1118/1.2736289
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Computer-aided detection (CAD) has been attracting extensive research interest during the last two decades. It is recognized that the full potential of CAD can only be realized by improving the performance and robustness of CAD algorithms and this requires good evaluation methodology that would permit CAD designers to optimize their algorithms. Free-response receiver operating characteristic (FROC) curves are widely used to assess CAD performance, however, evaluation rarely proceeds beyond determination of lesion localization fraction (sensitivity) at an arbitrarily selected value of nonlesion localizations (false marks) per image. This work describes a FROC curve fitting procedure that uses a recent model of visual search that serves as a framework for the free-response task. A maximum likelihood procedure for estimating the parameters of the model from free-response data and fitting CAD generated FROC curves was implemented. Procedures were implemented to estimate two figures of merit and associated statistics such as 95% confidence intervals and goodness of fit. One of the figures of merit does not require the arbitrary specification of an operating point at which to evaluate CAD performance. For comparison a related method termed initial detection and candidate analysis was also implemented that is applicable when all suspicious regions are reported. The two methods were tested on seven mammography CAD data sets and both yielded good to excellent fits. The search model approach has the advantage that it can potentially be applied to radiologist generated free-response data where not all suspicious regions are reported, only the ones that are deemed sufficiently suspicious to warrant clinical follow-up. This work represents the first practical application of the search model to an important evaluation problem in diagnostic radiology. Software based on this work is expected to benefit CAD developers working in diverse areas of medical imaging. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:2024 / 2038
页数:15
相关论文
共 50 条
  • [21] A COMPUTER-AIDED ALGORITHM FOR EVALUATING THERMOGRAMS OF THE HAND
    THOMAS, RE
    KENNEDY, EM
    HERRING, BE
    HERRICK, RT
    COMPUTERS & INDUSTRIAL ENGINEERING, 1994, 26 (03) : 501 - 509
  • [22] EVALUATING GRAPHICAL USER INTERFACES FOR COMPUTER-AIDED DETECTION OF BARRETT'S NEOPLASIA
    Jong, Martijn
    Jukema, Jelmer
    Fockens, Kiki
    Van Heslinga, Rixta Van Eijck
    Kusters, Koen
    Boers, Tim
    Jaspers, Tim
    Van der Sommen, Fons
    De With, P. H. N.
    De Groof, Jeroen
    Bergman, Jacques
    GASTROINTESTINAL ENDOSCOPY, 2024, 99 (06) : AB28 - AB28
  • [23] Computer-aided detection for screening mammography
    Woods, K
    Sallam, M
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS IX, PROCEEDINGS OF, 1999, 3590 : 490 - 497
  • [24] Computer-aided detection for CT colonography
    Xu Y.-R.
    Zhao J.
    Journal of Shanghai Jiaotong University (Science), 2014, 19 (05) : 531 - 537
  • [25] Computer-aided detection of amorphous calcifications
    Soo, MS
    Rosen, EL
    Xia, JQ
    Ghate, S
    Baker, JA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (03) : 887 - 892
  • [26] Computer-aided detection of breast cancer
    Milne, NC
    RADIOLOGY, 2004, 233 (02) : 615 - 616
  • [27] Reproducibility in mammographic computer-aided detection
    Worrell, S
    Collins, M
    Mitchell, R
    Hoffmeister, JW
    Bauer, K
    Rogers, SK
    Kabrisky, M
    CARS 2000: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2000, 1214 : 1042 - 1042
  • [28] Computer-aided detection for screening mammography
    Astley, SM
    ACADEMIC RADIOLOGY, 2004, 11 (10) : 1139 - 1143
  • [29] Computer-aided detection: There is no free lunch
    D'Orsi, CJ
    RADIOLOGY, 2001, 221 (03) : 585 - 586
  • [30] Computer-aided detection of breast cancer
    不详
    EUROPEAN JOURNAL OF CANCER, 2008, 44 (17) : 2536 - 2536