Three-dimensional analysis of endosseous palatal implants and bones after vertical, horizontal, and diagonal force application

被引:27
|
作者
Gedrange, T
Bourauel, C
Köbel, C
Harzer, W
机构
[1] Tech Univ Dresden, Dept Orthodont, D-8027 Dresden, Germany
[2] Univ Bonn, Dept Orthodont, D-5300 Bonn, Germany
关键词
D O I
10.1093/ejo/25.2.109
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The effects of bite and orthodontic forces exerted on endosseous palatal implants are not completely understood. This applies especially to the biomechanical properties inherent in the different implant geometries and resulting bone remodelling reactions on the one hand, and to the influence on the direction and magnitude of the applied forces on the other. The results of this study should help in the selection of implants for clinical use. Three types of endosseous implants (all 9 mm in length and 3.3 mm in diameter, made of titanium) were used for this investigation. Type 1 was a simple, cylinder-shaped implant; type 2 a cylinder-shaped implant with a superperiosteal step; and type 3 a cylinder-shaped implant, subperiosteally threaded, with a superperiosteal step. The load on the implant was investigated under three conditions of bite and orthodontic forces from 0.01 to 100 N (vertically, horizontally, and diagonally). The study results were calculated by means of a finite element (FE) method. Vertical loading caused bone deformation of more than 600 peps at the simple implant. The largest deformations at this load were found in the trabecular bone with all three implant geometries. However, trabecular bone deformation was reduced by a superperiosteal step. Horizontal loading of the implants shifted the deformation from the trabecular to the cortical bone. Furthermore, a large deformation was measured at the transition from cortical to trabecular bone. The smallest deformations (less than 300 peps) were found for implants with a superperiosteal step and diagonal loading (type 2). The use of threads provided no improvement in loading capacity. All implant types investigated showed good biomechanical properties. However, endosseous implants with a superperiosteal step had the best biomechanical properties under low loads. Thus, the trend should be to optimize the design of implants by producing small implants with additional anchorage on the bone surface.
引用
下载
收藏
页码:109 / 115
页数:7
相关论文
共 50 条
  • [1] Biomechanical optimisation of the length ratio of the two endosseous portions in distraction implants: a three-dimensional finite element analysis
    Gao, Yuan
    Li, Yong-Feng
    Shao, Bo
    Li, Tao
    Xia, Ning
    Xu, Li-Xian
    Wang, Zhong-Yi
    Kong, Liang
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2012, 50 (06): : E86 - E92
  • [2] THREE-DIMENSIONAL NUMERICAL ANALYSIS OF HORIZONTAL AND VERTICAL COALESCENCE OF BUBBLES AT TWO SUBMERGED HORIZONTAL ORIFICES ON THE WALL
    Li, Z. P.
    Sun, L. Q.
    Yao, X. L.
    Piao, Y.
    PROCEEDINGS OF THE ASME 38TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, 2019, VOL 2, 2019,
  • [3] Three-dimensional modelling of the vertical-horizontal rolling process
    Xiong, SW
    Rodrigues, JMC
    Martins, PAF
    FINITE ELEMENTS IN ANALYSIS AND DESIGN, 2003, 39 (11) : 1023 - 1037
  • [4] Three-dimensional force measurements on oral implants: a methodological study
    Duyck, J
    Van Oosterwyck, H
    De Cooman, M
    Puers, R
    Vander Sloten, J
    Naert, I
    JOURNAL OF ORAL REHABILITATION, 2000, 27 (09): : 744 - 753
  • [5] Three-Dimensional Force Measurements During Rapid Palatal Expansion in Sus scrofa
    Goeckner, Kelly
    Pepakayala, Venkatram
    Nervina, Jeanne
    Gianchandani, Yogesh
    Kapila, Sunil
    MICROMACHINES, 2016, 7 (04)
  • [6] Loading conditions of endosseous implants in an edentulous human mandible: A three-dimensional, finite-element study
    Meijer, HJA
    Starmans, FJM
    Steen, WHA
    Bosman, F
    JOURNAL OF ORAL REHABILITATION, 1996, 23 (11) : 757 - 763
  • [7] Force system generated by elastic archwires with vertical V bends: a three-dimensional analysis
    Upadhyay, Madhur
    Shah, Raja
    Peterson, Donald
    Asaki, Takafumi
    Yadav, Sumit
    Agarwal, Sachin
    EUROPEAN JOURNAL OF ORTHODONTICS, 2017, 39 (02) : 202 - 208
  • [8] Elongated horizontal and vertical receivers in three-dimensional electromagnetic modelling and inversion
    Patzer, Cedric
    Tietze, Kristina
    Ritter, Oliver
    GEOPHYSICAL PROSPECTING, 2019, 67 (08) : 2227 - 2244
  • [9] Three-dimensional analysis of tooth movements after palatal miniscrew-supported molar distalization
    Duran, Gokhan Serhat
    Gorgulu, Serkan
    Dindaroglu, Furkan
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2016, 150 (01) : 188 - 197
  • [10] Investigation of the Temperature and Horizontal Freezing Force of Loess in Three-Dimensional Freezing
    Yin, Yidan
    Liu, Fei
    Tang, Dongqi
    Chen, Longze
    Yang, Binbin
    MATERIALS, 2024, 17 (18)