The dependencies of SAW-transducer equivalent-circuit-model parameters on transducer geometry

被引:0
|
作者
Hickernell, TS [1 ]
机构
[1] Motorola Inc, Scottsdale, AZ 85252 USA
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A new equivalent-circuit (EC) model for SAW transducers has been developed which incorporates the measured dependencies of model parameters on the number of transducer electrode pairs, N, and the acoustic aperture. W. Three EC parameters that relate the transducer geometry to the circuit-model elements are the electrode-pair capacitance per unit length, C-e, the capacitance ratio, r, and the resonant velocity, V-r, which is proportional to the velocity of the SAW. For conventional transducer EC models these parameters are independent of N and W. Parameter values were extracted from RF waveguide-probe measurements of an array of SAW transducers with resonant frequencies near 900 MHz fabricated on 64 degrees Y-cut X-propagating lithium niobate. The transducers had numbers of electrode pairs ranging from 50 to 150, acoustic apertures ranging from 5 to 20 wavelengths, and bus-bar heights ranging from 5 to 15 wavelengths. Even with a fixed electrode width-to-pitch ratio and thickness-to-wavelength ratio, results showed approximately 25% variation in C-e, 50% variation in r, and 0.4% variation in V-r due to the variations in N and W. The parameters varied little with bus-bar height. The measured and computer-simulated responses of a SAW ladder filter designed for a GSM receiver application at 947 MHz were compared. The new model which accounts for geometrical variations in the EC parameters shows an improvement in accuracy over previous models.
引用
收藏
页码:127 / 130
页数:4
相关论文
共 50 条
  • [31] Electromechanical equivalent circuit of conical section radial composite ultrasonic transducer
    Wang, Xiaoyu
    Lin, Shuyu
    [J]. Shengxue Xuebao/Acta Acustica, 2021, 46 (02): : 271 - 280
  • [32] Experimental studies of equivalent circuit for operating-mode piezoelectric transducer
    Zhou, Hong-Quan
    Han, Lei
    [J]. Yadian Yu Shengguang/Piezoelectrics and Acoustooptics, 2006, 28 (05): : 543 - 544
  • [33] SYNTHESIS OF STEADY-STATE EQUIVALENT CIRCUIT OF A PIEZOELECTRIC ELECTROACOUSTIC TRANSDUCER
    JAMES, DB
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1962, 34 (12): : 1971 - &
  • [34] EFFECT OF RADIATION LOADING ON EQUIVALENT-CIRCUIT FOR A PIEZOELECTRIC POLYMER TRANSDUCER
    HUDIMAC, AA
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1976, 60 : S47 - S47
  • [35] Analysis of the crosstalk in an underwater planar array transducer by the equivalent circuit method
    Pyo, Seonghun
    Roh, Yongrae
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2017, 56 (07)
  • [36] Equivalent circuit and frequency response of the distributed eddy current in an electromagnetic transducer
    Ikegame, Toru
    Takagi, Kentaro
    [J]. 2018 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2018, : 114 - 119
  • [37] Equivalent Electrical Circuit Approach to Enhance a Transducer for Insulin Bioavailability Assessment
    Mancino, Francesca
    Nouri, Hanen
    Moccaldi, Nicola
    Arpaia, Pasquale
    Kanoun, Olfa
    [J]. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2024, 12 : 533 - 541
  • [38] Investigation of the equivalent circuit and performance of an ultrasonic transducer under a force load
    Rao, Zhongyu
    Shi, Dinghui
    Ye, Hongxian
    Hu, Xiaoping
    [J]. SMART MATERIALS AND STRUCTURES, 2023, 32 (11)
  • [39] Electromechanical equivalent circuit of radial composite ultrasonic transducer with a conical profile
    WANG Xiaoyu
    LIN Shuyu
    [J]. Chinese Journal of Acoustics, 2021, 40 (03) : 419 - 434
  • [40] Interdigital transducer analysis using equivalent PSpice model
    Urbanczyk, M
    Waltar, Z
    Jakubik, W
    [J]. ULTRASONICS, 2002, 39 (08) : 595 - 599