Ultrasensitive, real-time trace gas detection using a high-power, multimode diode laser and cavity ringdown spectroscopy

被引:21
|
作者
Karpf, Andreas [1 ]
Qiao, Yuhao [1 ]
Rao, Gottipaty N. [1 ]
机构
[1] Adelphi Univ, Dept Phys, Garden City, NY 11530 USA
关键词
DOWN SPECTROSCOPY; ABSORPTION-SPECTROSCOPY; OUTPUT SPECTROSCOPY; NO2;
D O I
10.1364/AO.55.004497
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a simplified cavity ringdown (CRD) trace gas detection technique that is insensitive to vibration, and capable of extremely sensitive, real-time absorption measurements. A high-power, multimode Fabry -Perot (FP) diode laser with a broad wavelength range (Delta lambda(laser) similar to 0.6 nm) is used to excite a large number of cavity modes, thereby reducing the detector's susceptibility to vibration and making it well suited for field deployment. When detecting molecular species with broad absorption features (Delta lambda(absorption) >> Delta lambda(laser)), the laser's broad linewidth removes the need for precision wavelength stabilization. The laser's power and broad linewidth allow the use of on-axis cavity alignment, improving the signal-to-noise ratio while maintaining its vibration insensitivity. The use of an FP diode laser has the added advantages of being inexpensive, compact, and insensitive to vibration. The technique was demonstrated using a 1.1 W (lambda = 400 nm) diode laser to measure low concentrations of nitrogen dioxide (NO2) in zero air. A sensitivity of 38 parts in 10(12) (ppt) was achieved using an integration time of 128 ms; for single-shot detection, 530 ppt sensitivity was demonstrated with a measurement time of 60 mu s, which opens the door to sensitive measurements with extremely high temporal resolution; to the best of our knowledge, these are the highest speed measurements of NO2 concentration using CRD spectroscopy. The reduced susceptibility to vibration was demonstrated by introducing small vibrations into the apparatus and observing that there was no measurable effect on the sensitivity of detection. (c) 2016 Optical Society of America
引用
收藏
页码:4497 / 4504
页数:8
相关论文
共 50 条
  • [31] New perspectives in ultrasensitive trace gas monitoring by cavity enhanced laser absorption spectroscopy
    Kachanov, A
    Romanini, D
    Chenevier, M
    Garnache, A
    Stoeckel, F
    AIR MONITORING AND DETECTION OF CHEMICAL AND BIOLOGICAL AGENTS II, 1999, 3855 : 51 - 61
  • [32] Real-time FPGA data collection of pulsed-laser cavity ringdown signals
    Spence, T. G.
    Calzada, M. E.
    Gardner, H. M.
    Leefe, E.
    Fontenot, H. B.
    Gilevicius, L.
    Hartsock, R. W.
    Boyson, T. K.
    Harb, C. C.
    OPTICS EXPRESS, 2012, 20 (08): : 8804 - 8814
  • [33] A high-power tapered and cascaded active multimode interferometer semiconductor laser diode
    赖伟江
    程远兵
    姚辰
    周代兵
    边静
    赵玲娟
    伍剑
    半导体学报, 2011, 32 (05) : 66 - 69
  • [34] A high-power tapered and cascaded active multimode interferometer semiconductor laser diode
    Lai Weijiang
    Cheng Yuanbing
    Yao Chen
    Zhou Daibing
    Bian Jing
    Zhao Lingjuan
    Wu Jian
    JOURNAL OF SEMICONDUCTORS, 2011, 32 (05)
  • [35] Deep level spectroscopy of high-power laser diode arrays
    Tomm, JW
    Barwolff, A
    Jaeger, A
    Elsaesser, T
    Bollmann, J
    Masselink, WT
    Gerhardt, A
    Donecker, J
    JOURNAL OF APPLIED PHYSICS, 1998, 84 (03) : 1325 - 1332
  • [36] Laser-induced phosphorescence and cavity Ringdown spectroscopy for real time in situ detection of glyoxal at atmospherically relevant concentrations
    Huisman, Andrew J.
    Hottle, John R.
    Galloway, Melissa M.
    Keutsch, Frank N.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233
  • [37] Catastrophic Optical Damage in High-Power Diode Lasers Monitored by Real-Time Imaging
    Ziegler, Mathias
    Tomm, Jens W.
    Elsaesser, Thomas
    Matthiesen, Clemens
    2008 CONFERENCE ON LASERS AND ELECTRO-OPTICS & QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE, VOLS 1-9, 2008, : 2145 - +
  • [38] Large optical cavity waveguides for high-power diode laser applications
    Malyarchuck, V
    Tomm, JW
    Günther, T
    Müller, R
    Kunkel, R
    Lienau, C
    Luft, J
    IN-PLANE SEMICONDUCTOR LASERS V, 2001, 4287 : 111 - 117
  • [39] Direct, Real-time, High-resolution Beam profiler for High-power Laser
    Tsunekane, M.
    Sato, K.
    Takahashi, T.
    Yoshino, S.
    Yoshimori, N.
    Ohno, J.
    HIGH-POWER LASER MATERIALS PROCESSING: APPLICATIONS, DIAGNOSTICS, AND SYSTEMS IX, 2020, 11273
  • [40] A REAL-TIME VISUAL-DISPLAY OF A HIGH-POWER LASER-BEAM
    BOYD, IW
    CROWDER, JG
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1982, 15 (04): : 421 - 422